<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">MR</journal-id><journal-title-group>
    <journal-title>Magnetic Resonance</journal-title>
    <abbrev-journal-title abbrev-type="publisher">MR</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Magn. Reson.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">2699-0016</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/mr-5-143-2024</article-id><title-group><article-title>Design and performance of an oversized-sample  35 GHz EPR resonator with an elevated <inline-formula><mml:math id="M1" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value</article-title><alt-title>Q-band EPR resonator</alt-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" equal-contrib="yes" corresp="no" rid="aff1">
          <name><surname>Fischer</surname><given-names>Jörg Wolfgang Anselm</given-names></name>
          
        <ext-link>https://orcid.org/0000-0003-1525-8242</ext-link></contrib>
        <contrib contrib-type="author" equal-contrib="yes" corresp="no" rid="aff1">
          <name><surname>Stropp</surname><given-names>Julian</given-names></name>
          
        <ext-link>https://orcid.org/0009-0002-8278-5683</ext-link></contrib>
        <contrib contrib-type="author" equal-contrib="yes" corresp="no" rid="aff1">
          <name><surname>Tschaggelar</surname><given-names>René</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Oberhänsli</surname><given-names>Oliver</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Alaniva</surname><given-names>Nicholas</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Inoue</surname><given-names>Mariko</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff2">
          <name><surname>Mashima</surname><given-names>Kazushi</given-names></name>
          
        <ext-link>https://orcid.org/0000-0002-1316-2995</ext-link></contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Barnes</surname><given-names>Alexander Benjamin</given-names></name>
          
        </contrib>
        <contrib contrib-type="author" corresp="no" rid="aff1">
          <name><surname>Jeschke</surname><given-names>Gunnar</given-names></name>
          
        <ext-link>https://orcid.org/0000-0001-6853-8585</ext-link></contrib>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Klose</surname><given-names>Daniel</given-names></name>
          <email>daniel.klose@phys.chem.ethz.ch</email>
        <ext-link>https://orcid.org/0000-0002-3597-0889</ext-link></contrib>
        <aff id="aff1"><label>1</label><institution>Institute for Molecular Physical Science, ETH Zurich, Vladimir-Prelog-Weg 2, 8093 Zurich, Switzerland</institution>
        </aff>
        <aff id="aff2"><label>2</label><institution>Department of Chemistry Graduate School of Engineering Science, Osaka University,  1–3 Machikaneyama-cho, Toyonaka, Osaka 560-8531, Japan</institution>
        </aff><author-comment content-type="econtrib"><p>These authors contributed equally to this work.</p></author-comment>
      </contrib-group>
      <author-notes><corresp id="corr1">Daniel Klose (daniel.klose@phys.chem.ethz.ch)</corresp></author-notes><pub-date><day>20</day><month>September</month><year>2024</year></pub-date>
      
      <volume>5</volume>
      <issue>2</issue>
      <fpage>143</fpage><lpage>152</lpage>
      <history>
        <date date-type="received"><day>29</day><month>April</month><year>2024</year></date>
           <date date-type="rev-request"><day>7</day><month>May</month><year>2024</year></date>
           <date date-type="rev-recd"><day>4</day><month>July</month><year>2024</year></date>
           <date date-type="accepted"><day>3</day><month>August</month><year>2024</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2024 Jörg Wolfgang Anselm Fischer et al.</copyright-statement>
        <copyright-year>2024</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://mr.copernicus.org/articles/5/143/2024/mr-5-143-2024.html">This article is available from https://mr.copernicus.org/articles/5/143/2024/mr-5-143-2024.html</self-uri><self-uri xlink:href="https://mr.copernicus.org/articles/5/143/2024/mr-5-143-2024.pdf">The full text article is available as a PDF file from https://mr.copernicus.org/articles/5/143/2024/mr-5-143-2024.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d1e182">Continuous-wave electron paramagnetic resonance (EPR) spectroscopy at 35 GHz is an essential cornerstone in multi-frequency EPR studies and is crucial for differentiating multiple species in complex systems due to the improved <inline-formula><mml:math id="M2" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula>-tensor resolution compared to lower microwave frequencies. Especially for unstable and highly sensitive paramagnetic centers, the reliability of the measurements can be improved upon through the use of a single sample for EPR experiments at all frequencies. Besides the advantages, the lack of common availability of oversized-sample resonators at 35 GHz often limits scientists to lower frequencies or smaller sample geometries, and the latter may be non-trivial for sensitive materials. In this work, we present the design and performance of an oversized-sample 35 GHz EPR resonator with a high loaded <inline-formula><mml:math id="M3" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value, <inline-formula><mml:math id="M4" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, of up to 2550, well-suited for continuous-wave EPR and pulsed single-microwave-frequency experiments. The design is driven by electromagnetic field simulations, and the microwave characteristics of manufactured prototypes were found to be in agreement with the predictions. The resonator is based on a cylindrical cavity with a TE<inline-formula><mml:math id="M5" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> mode, allowing for 3 mm sample access. The design targets that we met include high sensitivity, robustness, and ease of manufacturing and maintenance. The resonator is compatible with commercial EPR spectrometers and with helium flow, as well as with cryogen-free cryostats, allowing for measurements at temperatures down to 1.8 K. To highlight the general applicability, the resonator was tested on metal centers, as well as on organic radicals featuring extremely narrow lines.</p>
  </abstract>
    
<funding-group>
<award-group id="gs1">
<funding-source>Eidgenössische Technische Hochschule Zürich</funding-source>
<award-id>ETH-35221</award-id>
</award-group>
<award-group id="gs2">
<funding-source>Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung</funding-source>
<award-id>200021_201070/1</award-id>
</award-group>
</funding-group>
</article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d1e228">Electron paramagnetic resonance (EPR) spectroscopy is a versatile and sensitive technique ideally suited to probe paramagnetic centers, even in complex environments such as heterogeneous catalysts <xref ref-type="bibr" rid="bib1.bibx2" id="paren.1"/>. Chemical and structural information on the paramagnetic center is encoded in parameters of the effective spin Hamiltonian, describing the unpaired electron spin(s), as well as coupled magnetic nuclei <xref ref-type="bibr" rid="bib1.bibx25 bib1.bibx27" id="paren.2"/>. For systems with a single electron spin (<inline-formula><mml:math id="M6" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>), the solid-state continuous-wave (CW) EPR spectra measured at the common frequency of 9.5 GHz (i.e., X band) are dominated by the anisotropic Zeeman interaction and the anisotropic hyperfine interaction described by the <inline-formula><mml:math id="M7" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula> tensor and the <inline-formula><mml:math id="M8" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula> tensor, respectively. For the case of significant <inline-formula><mml:math id="M9" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M10" display="inline"><mml:mi>A</mml:mi></mml:math></inline-formula> anisotropy, as found in transition metal complexes, spectra can be several gigahertz wide. Accordingly, for many applications, a high sensitivity is essential. Key determining factors for the sensitivity of an EPR spectrometer are the resonator properties, including the sample volume it allows.</p>
      <p id="d1e282">In addition to sufficient sensitivity, resolution and spectral overlap are of concern for the analysis of complex samples, such as heterogeneous catalysts, where several paramagnetic species may be present. Already for a single anisotropic paramagnetic species, the number of parameters in the spin Hamiltonian is regularly beyond what can be resolved in a single CW EPR spectrum <xref ref-type="bibr" rid="bib1.bibx19" id="paren.3"/>. The presence of several paramagnetic species often leads to severe spectral overlap, which occludes access to the full information on each individual species inherent in the CW EPR line shape. To alleviate this challenge, multi-frequency EPR is employed as an essential tool to deconvolute overlapping spectral components and to constrain the full set of the anisotropic interactions in the spin Hamiltonian <xref ref-type="bibr" rid="bib1.bibx18" id="paren.4"/>. Multi-frequency EPR typically makes use of a combination of frequencies and corresponding magnetic field ranges, with the most accessible frequencies being <inline-formula><mml:math id="M11" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 4 GHz (S band), <inline-formula><mml:math id="M12" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 9.5 GHz (X band), <inline-formula><mml:math id="M13" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 35 GHz (Q band), and <inline-formula><mml:math id="M14" display="inline"><mml:mo>∼</mml:mo></mml:math></inline-formula> 95 GHz (W band). This serves, first, to disentangle the field-dependent Zeeman interaction and the field-independent hyperfine interaction and, second, to increase the spectral resolution for the <inline-formula><mml:math id="M15" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula> tensor at higher fields. This approach is known to aid in the differentiation of multiple spectral species <xref ref-type="bibr" rid="bib1.bibx18" id="paren.5"/>. For samples with (residual) motion of the paramagnetic centers, the different frequencies are sensitive to different motional averaging time windows; hence, multi-frequency EPR can also enhance studies of the inherent dynamics <xref ref-type="bibr" rid="bib1.bibx35" id="paren.6"/>.</p>
      <p id="d1e333">An important concern for global analysis of multi-frequency EPR data is the line shape of the spectra when obtained with either CW or pulsed EPR excitation. Pulsed EPR acquires spectra via detection of an electron spin echo or a free induction decay (FID) and can be sensitive towards broad signals with small slopes in the absorption spectrum. Yet, typically, pulsed EPR has a reduced line shape fidelity or sensitivity compared to CW EPR experiments for two main reasons. First, using high microwave power for pulse excitation leads to instrumental dead time due to the need for transient receiver protection. This dead time can, however, make up a significant fraction of the transverse relaxation time, leading to signal loss, which is especially troublesome in cases where the relaxation is anisotropic across the spectrum. Second, electron spin echo envelope modulation (ESEEM) due to nuclear hyperfine interactions exhibits a magnetic-field-dependent initial phase and may thus lead to distortions of the absorption spectrum unless long inter-pulse delays are used. Due to these considerations, the observed relative intensities of different species and also those within a single spectral species may differ between CW and pulsed EPR spectra, yet only the CW EPR line shape in the absence of microwave power saturation is insensitive to relaxation time differences.</p>
      <p id="d1e336">For samples of limited stability, such as catalysts that are highly sensitive to oxygen or moisture, or for samples that are challenging to reproduce quantitatively, such as ex situ freeze-trapped reaction intermediates, it is highly advantageous to record multi-frequency EPR data on the very same sample. This requires resonators that allow for the same sample tube diameter at different microwave frequencies <xref ref-type="bibr" rid="bib1.bibx31" id="paren.7"/> and is particularly important for a quantitative global analysis by spectral simulations <xref ref-type="bibr" rid="bib1.bibx30" id="paren.8"/>, where variations in the relative contributions of different species between the spectra taken at different frequencies cannot be tolerated. With sample dimensions in EPR spectroscopy being comparable to the wavelength, at least at the higher frequencies, the requirement to measure the same sample at different frequencies poses a technical challenge. Sensitivity optimization requires larger sample volumes at lower frequencies <xref ref-type="bibr" rid="bib1.bibx18" id="paren.9"/>, with typical sample tube outer diameters (ODs) of 5 mm at S-band frequencies and of 4 mm at X-band frequencies. However, even an OD of 3 mm already exceeds a quarter of the wavelength at Q-band frequencies and corresponds to the approximate wavelength at W-band frequencies. When we consider a 3 mm OD sample tube as a reasonable compromise, the sample is thus <italic>oversized</italic> at Q- and W-band frequencies. Therefore, the properties of the resonant cavity are strongly influenced by the dielectric properties of the sample tube and the sample. This poses a challenge for the design of a robust cavity resonator, particularly for CW EPR, where adequate sensitivity requires a high quality (<inline-formula><mml:math id="M16" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula>) factor.</p>
      <p id="d1e359">For Q-band frequencies of about 33–36 GHz, different types of resonators have been designed and evaluated. Loop-gap resonators, originally introduced by <xref ref-type="bibr" rid="bib1.bibx9" id="text.10"/>, are well-suited to concentrate the microwave <inline-formula><mml:math id="M17" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field to a limited sample volume. Several designs of Q-band loop-gap resonators have been published <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx7 bib1.bibx3" id="paren.11"/>, and <inline-formula><mml:math id="M18" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> fields corresponding to a Rabi frequency of 40 MHz over bandwidths <inline-formula><mml:math id="M19" display="inline"><mml:mo>&gt;</mml:mo></mml:math></inline-formula> 1 GHz have been achieved <xref ref-type="bibr" rid="bib1.bibx32" id="paren.12"/>. However, scaling to larger sample diameters strongly deteriorates the performance of loop-gap resonators. Also, for high-<inline-formula><mml:math id="M20" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> and large-bandwidth pulsed EPR applications, a cylindrical resonator operating with the TE<inline-formula><mml:math id="M21" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> mode was computed for an oversized sample with 3 mm OD, whereas the actual resonator used a central dielectric ring for enhancing the <inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field for a smaller sample OD of 1.8 mm <xref ref-type="bibr" rid="bib1.bibx22" id="paren.13"/>. For the 3 mm OD sample access that we are aiming for here, cubic box resonators in TE<inline-formula><mml:math id="M23" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">102</mml:mn></mml:msub></mml:math></inline-formula> mode <xref ref-type="bibr" rid="bib1.bibx31 bib1.bibx21" id="paren.14"/> and cylindrical cavity resonators in TE<inline-formula><mml:math id="M24" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> mode <xref ref-type="bibr" rid="bib1.bibx24 bib1.bibx14 bib1.bibx26 bib1.bibx11 bib1.bibx29" id="paren.15"/> have been developed for different applications. Among these, the cylindrical cavities feature a higher <inline-formula><mml:math id="M25" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> factor, as well as a better conversion factor, and the larger sample volumes overcompensate for their poorer filling factors compared to commercial dielectric resonators <xref ref-type="bibr" rid="bib1.bibx23" id="paren.16"/>.</p>
      <p id="d1e470">Here, based on the design target of a high-<inline-formula><mml:math id="M26" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> Q-band resonator for oversized samples suitable for CW EPR with high sensitivity, we report on the design and performance of a robust, simple cylindrical TE<inline-formula><mml:math id="M27" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula>-mode cavity resonator for 3 mm OD sample tubes. While suitable primarily for sensitive CW EPR experiments, the resonator can be also used for pulsed single-microwave-frequency experiments, particularly if a long receiver protection, and hence spectrometer dead time, can be tolerated. The resonator design is based on electromagnetic field modeling by finite-element calculations in order to minimize the effect of electric fields in the sample and to optimize the <inline-formula><mml:math id="M28" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> factor. The experimentally determined characteristics are in good agreement with the calculated properties, highlighting the advantage of a design approach based on electromagnetic field simulations. The resonator performance was tested on a scope of samples including a homogeneous, multi-component Ti(III) catalyst in toluene under cryogenic conditions and at room temperature to demonstrate the general applicability. The linewidth resolution was demonstrated with an N@C<inline-formula><mml:math id="M29" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula> sample to be better than <inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> mT.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Materials and methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Finite-element simulations of electromagnetic structures</title>
      <p id="d1e534">Electric field and magnetic field calculations were carried out by finite-element simulations with the software CST Microwave Studio (CST GmbH, Darmstadt, Germany), which uses a volume grid discretization. The geometric structure was modeled in silico, with all parts of the resonator in contact with the microwave fields. Out-of-resonance losses were fitted by assigning a surface conductivity of <inline-formula><mml:math id="M31" display="inline"><mml:mrow><mml:mn mathvariant="normal">3</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mn mathvariant="normal">4</mml:mn></mml:msup></mml:mrow></mml:math></inline-formula> S m<inline-formula><mml:math id="M32" display="inline"><mml:msup><mml:mi/><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> to the waveguide and other (non-ideal) surfaces. All metal structures were calculated using a surface impedance model to incorporate resistive losses. The geometry of the resonator has been parameterized and optimized in terms of center frequency, bandwidth, <inline-formula><mml:math id="M33" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field strength, sample volume (filling height of a sample tube with 3.0 mm OD, 2.2 mm inner diameter (ID)), and coupler position for different sample materials (with relative dielectric constants ranging from 1 for empty tubes up to 3 for frozen aqueous samples; <xref ref-type="bibr" rid="bib1.bibx15" id="altparen.17"/>). The frequency shift of the resonator upon introduction of the sample tube could be reproduced using a relative permittivity of 3.4 for the quartz sample tube at Q-band frequencies.</p>
      <p id="d1e578">Simulations of the input reflection coefficient <inline-formula><mml:math id="M34" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> were used to describe the measured microwave reflection curves. For comparison with the experimental results obtained on a point sample, the microwave field and frequency were simulated at specific locations within the resonator, excluding losses and surface imperfections.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Microwave reflection curves and resonator characterization</title>
      <p id="d1e600">The experimental microwave reflection curves were measured as the scattering parameter <inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> with a calibrated network analyzer (HP 8722ES) and a source power of <inline-formula><mml:math id="M36" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">10</mml:mn></mml:mrow></mml:math></inline-formula> dBm at room temperature. The simulated microwave reflection curves with the input reflection coefficient <inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> were obtained from finite-element simulations as described above. Details on the calculation of the <inline-formula><mml:math id="M38" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> parameter and the half-power points (<inline-formula><mml:math id="M39" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mrow><mml:mi mathvariant="normal">hp</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>) for the <inline-formula><mml:math id="M40" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value calculation and the filling factor <inline-formula><mml:math id="M41" display="inline"><mml:mi mathvariant="italic">η</mml:mi></mml:math></inline-formula> are given in Sects. S1, S2, and in Fig. S1 in the Supplement.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>Prototype fabrication</title>
      <p id="d1e681">The resonator cavity, including the iris, was fabricated from a solid block of copper metal (purity 99.95 %, ThyssenKrupp, Essen, Germany) by wire erosion to yield suitably smooth surfaces. The iris groove was cut from the outside by CNC milling, with the coupling rod (1 mm, copper) positioned between the iris and WR28 waveguide (copper, Penn Engineering Components, Valencia, USA). The modulation coils consist of 30 turns of lacquer-isolated copper wire with a diameter of 0.35 mm. The coils were wound in a rectangular arrangement with a height of 20 mm and a width of 15 mm, and they were mounted at a distance of 25 mm. With an induction of 350 <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>H, a root-mean-square (rms) current of 250 mA is required for a modulation amplitude of 0.1 mT.</p>
</sec>
<sec id="Ch1.S2.SS4">
  <label>2.4</label><title>Sample preparation</title>
      <p id="d1e700">Diphenyl-1-picrylhydrazyl (DPPH, Sigma, Buchs, Switzerland) radical powder, N@C<inline-formula><mml:math id="M43" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula> (powder, 6.15 mg, 10 ppm spin-diluted with C<inline-formula><mml:math id="M44" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula>, Designer Carbon Materials Ltd., Oxford, UK) <xref ref-type="bibr" rid="bib1.bibx8 bib1.bibx5 bib1.bibx13" id="paren.18"/>, or 20 <inline-formula><mml:math id="M45" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>L, 100 <inline-formula><mml:math id="M46" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>M (4-Hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl – TEMPOL) radical solution in toluene were filled into 3.0 mm OD (ca. 2.4 mm ID) sample tubes made from Heraeus HSQ300 electrically fused quartz (Aachener Quarzglas, Aachen, Germany). The Herasil sample was a cylinder with a height of 6 mm and a diameter of 2.4 mm that was <inline-formula><mml:math id="M47" display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula>-irradiated with a dose of 2 kGy. The titanium catalyst in toluene solution was prepared in a glove box under Ar atmosphere by using a Ti(IV) organometallic precursor reduced to Ti(III) by trimethylaluminum; details will be described elsewhere. The filling height for the samples was ca. 8 mm, except for Herasil, TEMPOL, and DPPH; the latter was prepared using a small visible amount to approximate a point sample.</p>
</sec>
<sec id="Ch1.S2.SS5">
  <label>2.5</label><title>EPR measurements</title>
      <p id="d1e757">Room-temperature CW EPR experiments, as well as the nutation measurements by pulsed EPR, were performed on a home-built pulse/CW Q-band EPR spectrometer equipped with a helium flow cryostat (CF935, Oxford Instruments, Oxfordshire, UK) and a traveling wave tube amplifier (nominal power of 150 W) described by <xref ref-type="bibr" rid="bib1.bibx10" id="paren.19"/>. For experiments at room temperature, the temperature of the resonator was maintained by a gentle flow of dry nitrogen gas through the cryostat. For DPPH, a microwave power of 0.32 <inline-formula><mml:math id="M48" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>W, a lock-in time constant of 20.48 ms, and a conversion time of 81.92 ms were used; the modulation frequency was set to 100 kHz; and the modulation amplitude was set to 0.02 mT. The Rabi nutation experiment was performed using a <inline-formula><mml:math id="M49" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mtext>p</mml:mtext></mml:msub><mml:mo>-</mml:mo><mml:mi>T</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="italic">π</mml:mi><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn><mml:mo>-</mml:mo><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="italic">π</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="italic">τ</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="normal">echo</mml:mi></mml:mrow></mml:math></inline-formula> pulse sequence, and the input power into the resonator during the pulses was subsequently measured at the microwave bridge output with a 437B RF power meter (Keysight). The CW EPR spectra of the titanium catalyst and for N@C<inline-formula><mml:math id="M50" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula> were measured on a commercial EPR spectrometer (ELEXSYS E580, Bruker Biospin, Rheinstetten, Germany), equipped with a cryogen-free variable-temperature EPR cryostat (Cryogenic Ltd., London, UK). The Ti(III) spectra were recorded without over-modulation with a modulation frequency of 100 kHz. At room temperature, 0.1 mT modulation amplitude, 161.84 ms conversion time, and 0.57 <inline-formula><mml:math id="M51" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>W microwave power were used, while at 30 K, the settings were 0.1 mT, 81.92 ms, and 0.23 <inline-formula><mml:math id="M52" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>W, respectively. The N@C<inline-formula><mml:math id="M53" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula> was measured at room temperature, with a modulation frequency of 100 kHz and a modulation amplitude of 0.002 mT. A microwave power of 0.23 <inline-formula><mml:math id="M54" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>W and a conversion time of 160 ms were used. CW EPR parameters were chosen for optimal signal-to-noise ratios while avoiding power saturation of the samples, as well as saturation of the receiver chain of the spectrometer. An overview of all measurement parameters can be found in Table S1 in the Supplement.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Results and discussion</title>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Resonator design</title>
      <p id="d1e870">The Q-band resonator is designed for sample tubes up to 3 mm OD and a temperature range from 1.8 to 298 K in continuous He flow cryostats or cryogen-free systems. Special focus was placed on low losses for a high <inline-formula><mml:math id="M55" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> factor, suitability for applications with different solvents, repeatable manufacturability, robust design, and easy handling and cleaning. This is achieved by a cylindrical TE<inline-formula><mml:math id="M56" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> cavity (9 mm height, 11.5 mm diameter) in a copper block with modulation coils from copper wire that are mounted on both outer sides of the cavity block (Fig. <xref ref-type="fig" rid="Ch1.F1"/>a). The modulation field at the sample position for a given current in the modulation coils is enhanced by horizontal slots in the copper block dissecting the entire length of the lateral walls (Fig. <xref ref-type="fig" rid="Ch1.F1"/>a). Electromagnetic field simulations have been performed by systematically varying the slot size for the resonator between 0.2 and 0.8 mm in 0.5 mm steps. The resulting <inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> curves (Fig. S2) exhibit a minimum of the dip around 0.5 mm, which was hence chosen to manufacture the resonator. While in this optimization approach the modulation field is not calculated, a more involved approach such as that performed by <xref ref-type="bibr" rid="bib1.bibx28" id="text.20"/> might further improve the performance of the resonator.</p>
      <p id="d1e908">The cavity height-to-diameter ratio was optimized for minimum reflection (dip depth) at a frequency around 34.2 GHz with an empty sample tube. The obtained geometry (9 mm <inline-formula><mml:math id="M58" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 11.5 mm; see Table S2) is close to, yet not the same as, that of the TE<inline-formula><mml:math id="M59" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> resonator designed by <xref ref-type="bibr" rid="bib1.bibx24" id="text.21"/>. The deviation from the expected optimum with a ratio of 1 : 1 may arise due to the interaction of the electromagnetic fields with the oversized sample. With the optimized cavity height-to-diameter ratio, unwanted modes are suppressed or shifted out of the targeted frequency range. In case of sample damage in the cavity, the removable bottom plate of the resonator allows for efficient cleaning. The microwave power is provided through a waveguide, made from copper in the bottom part and from stainless steel in the upper part to reduce thermal conductivity. The coupling of the microwave from the waveguide into the cavity is adjusted by a copper coupler in front of the iris (0.5 <inline-formula><mml:math id="M60" display="inline"><mml:mo>×</mml:mo></mml:math></inline-formula> 3.0 mm with rounded ends). Rotating the coupling knob at the top flange of the probe head tilts the coupler by some degrees from the vertical position and thereby changes the coupling. This is achieved by a thread just above the cavity, which converts the rotation into a tilt. The 3 mm OD sample tube held by the tip of a sample tube holder is guided in a 8 mm Vetronite tube from the top flange to the resonator at its bottom. For precise and reproducible positioning, the sample tube is inserted through a conical guide into the center of the cavity.</p>

      <fig id="Ch1.F1" specific-use="star"><label>Figure 1</label><caption><p id="d1e939"><bold>(a)</bold> Rendering of the Q-band EPR resonator with a cross section view of certain parts to show the technical functionality: EPR tube (1), slits for modulation field (2), cavity (3), modulation coil holder (4), iris (5), coupler (6), coupling waveguide (7), coupling mechanism (8, movement indicated by green arrows), and holder of the movable coupling piston (9). <bold>(b–e)</bold> <inline-formula><mml:math id="M61" display="inline"><mml:mi mathvariant="bold-italic">B</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M62" display="inline"><mml:mi mathvariant="bold-italic">E</mml:mi></mml:math></inline-formula> field simulations of the resonator with an empty quartz EPR tube (<inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϵ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3.4</mml:mn></mml:mrow></mml:math></inline-formula>); isolines are spaced in 6 % steps of the maximum field strength with <inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:mi>z</mml:mi><mml:mo>|</mml:mo><mml:mo>|</mml:mo><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> (see <bold>a</bold>); all cross sections run through the center of the cavity. <bold>(b)</bold> Strength of the <inline-formula><mml:math id="M65" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> component of the <inline-formula><mml:math id="M66" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field in a horizontal cross section. <bold>(c)</bold> Strength of the <inline-formula><mml:math id="M67" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> component of the <inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field in a vertical cross section. <bold>(d)</bold> Strength of the tangential <inline-formula><mml:math id="M69" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field  in a horizontal cross section. <bold>(e)</bold> Strength of the <inline-formula><mml:math id="M70" display="inline"><mml:mi>z</mml:mi></mml:math></inline-formula> component of the <inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field in a vertical cross section.</p></caption>
          <graphic xlink:href="https://mr.copernicus.org/articles/5/143/2024/mr-5-143-2024-f01.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Simulations and experimental characterization of the resonator</title>
      <p id="d1e1086">The electromagnetic field configurations in the cavity were simulated and are depicted in Fig. <xref ref-type="fig" rid="Ch1.F1"/>b–e. Figure <xref ref-type="fig" rid="Ch1.F1"/>b and c show horizontal and vertical cross sections through the cavity, with the simulated <inline-formula><mml:math id="M72" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> component of the magnetic field <inline-formula><mml:math id="M73" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> of the incident microwaves. Since the <inline-formula><mml:math id="M74" display="inline"><mml:mi>x</mml:mi></mml:math></inline-formula> component of <inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is orthogonal to the horizontal external magnetic field <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> along <inline-formula><mml:math id="M77" display="inline"><mml:mi>z</mml:mi></mml:math></inline-formula>, the excitation of electron spins depends linearly on its strength. In Fig. <xref ref-type="fig" rid="Ch1.F1"/>, the space between the isolines corresponds to 6 % steps of the maximum field strength. Vertically, within <inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:mo>±</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula> mm around the position with the maximum <inline-formula><mml:math id="M79" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field strength, the field decays to about 80 %. The horizontal, radial decay of <inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> inside the sample (2.2 mm inner diameter) is below 10 % and, therefore, is negligible compared to the vertical decay. Spins which are located outside the vertical center region will experience a lower <inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field and hence will contribute to a smaller extent to the EPR signal. This is verified experimentally by the measurement of a point sample at different vertical positions in the resonator (Fig. <xref ref-type="fig" rid="Ch1.F2"/>). The magnetic field strength and its distribution showed only slight changes for samples with different dielectric constants. Observing the magnetic vector field across the range of conditions that we target with the present design, we found that the phase of the magnetic field remains constant over the volume of the sample, an example of which is shown in Fig. S3.</p>
      <p id="d1e1196">The electric field distribution of the TE<inline-formula><mml:math id="M82" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> mode is shown in Fig. <xref ref-type="fig" rid="Ch1.F1"/>d and e. The cavity is designed such that the electric field in the sample volume is minimized to avoid sample heating and a reduction of the <inline-formula><mml:math id="M83" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value due to lossy samples <xref ref-type="bibr" rid="bib1.bibx31" id="paren.22"/>. Samples with a high dielectric constant focus the magnetic field <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> in the center. This leads to an increase in the electric field <inline-formula><mml:math id="M85" display="inline"><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> at the sample borders, which induces a reduction in the <inline-formula><mml:math id="M86" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value. This effect can also be seen when comparing microwave field simulations of the resonator with an EPR tube (Fig. <xref ref-type="fig" rid="Ch1.F1"/>) and without an EPR tube (Fig. S4), as well as in the increasing filling factor with increasing <inline-formula><mml:math id="M87" display="inline"><mml:mi mathvariant="italic">ϵ</mml:mi></mml:math></inline-formula> of the sample (Table S3). Whereas for an empty clear fused quartz tube the electric field penetrates only slightly into the interior of the tube, this penetration becomes stronger if the EPR tube is filled with a sample with a high dielectric constant such as liquid water. Particularly without an EPR tube, the electric field is not perfectly symmetric, as expected for a pure TE<inline-formula><mml:math id="M88" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> mode, but has a visible distortion due to a weak TE<inline-formula><mml:math id="M89" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">311</mml:mn></mml:msub></mml:math></inline-formula> mode contribution (Figs. <xref ref-type="fig" rid="Ch1.F1"/>d and S4c). <xref ref-type="bibr" rid="bib1.bibx16" id="text.23"/> showed that these distortions can lead to microwave leakage through the modulation slots, thus reducing the resonator <inline-formula><mml:math id="M90" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value; however, the low intensity of the second mode observed in the simulations suggests that the effect is minor in this case.</p>

      <fig id="Ch1.F2" specific-use="star"><label>Figure 2</label><caption><p id="d1e1292"><bold>(a)</bold> Frequency of the resonator mode as a function of the position of a DPPH point sample (blue) and corresponding simulations (red). <bold>(b)</bold> Double-integral intensity of the corresponding DPPH sample at the same positions (blue) and the expected intensity from the simulations (red). </p></caption>
          <graphic xlink:href="https://mr.copernicus.org/articles/5/143/2024/mr-5-143-2024-f02.png"/>

        </fig>

      <p id="d1e1307">To map the sensitivity profile of the resonator as a guide for designing experiments, we probed the distribution of the magnetic component of the microwave field in the resonator and the shift of the resonance frequency upon sample insertion using a DPPH point sample with a defined EPR transition at <inline-formula><mml:math id="M91" display="inline"><mml:mrow><mml:mi>g</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">2.0036</mml:mn></mml:mrow></mml:math></inline-formula> <xref ref-type="bibr" rid="bib1.bibx4" id="paren.24"/>. The inserted sample was moved in steps of 1 mm from the bottom to the upper end of the resonator cavity. The frequency of the minimum of the reflection curve was measured with an external frequency counter as a function of the sample position (Fig. <xref ref-type="fig" rid="Ch1.F2"/>a). At each sample position, the spectrum of DPPH was measured, and the double-integral intensity was computed (Fig. <xref ref-type="fig" rid="Ch1.F2"/>b). Figure <xref ref-type="fig" rid="Ch1.F2"/>a shows that the measured and the predicted frequency shifts are in good agreement with each other for all sample positions. In Fig. <xref ref-type="fig" rid="Ch1.F2"/>b, the normalized double-integral intensity after linear baseline correction is shown in comparison with the <inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field strength simulations. The measured CW EPR signal intensity of DPPH matches the one expected from simulations well. The experiment shows that the active height of the resonator is around 6 mm, which corresponds to an active sample volume of about 30 <inline-formula><mml:math id="M93" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>L for a 3 mm OD sample tube; as expected, the maximum <inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field is about 3–5 mm from the bottom, which corresponds to the center of the resonator.</p>

      <fig id="Ch1.F3" specific-use="star"><label>Figure 3</label><caption><p id="d1e1366"><bold>(a)</bold> Experimental frequency of the resonator mode as a function of the coupler position (tilt angle) without and with a clear fused quartz sample tube. No additional modes are observed in the range of 34–36 GHz. <bold>(b)</bold> The corresponding simulations with the same color code. <bold>(c)</bold> Positions of the coupler used for the simulation from left to right, <inline-formula><mml:math id="M95" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> to <inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:mo>+</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>°. The coupling element is highlighted in blue.</p></caption>
          <graphic xlink:href="https://mr.copernicus.org/articles/5/143/2024/mr-5-143-2024-f03.png"/>

        </fig>

      <p id="d1e1403">To adjust the coupling for a range of samples with different dielectric constants, we tested a coupling element where the angle of the copper coupling rod with respect to the iris determines the coupling strength (Fig. <xref ref-type="fig" rid="Ch1.F1"/>a). The design allows for a broader range over which the coupling can be adjusted compared to the previous copper ring moving vertically in front of the iris on a PEEK rod <xref ref-type="bibr" rid="bib1.bibx31" id="paren.25"/>. Therefore, the effect of the coupler tilt angle was investigated in more detail. Figure <xref ref-type="fig" rid="Ch1.F3"/> displays the simulated and experimental microwave reflection curves for different positions of the coupling element. The coupling element was moved between <inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:mo>+</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>° around the resting position at 0° tilt angle. The frequency and <inline-formula><mml:math id="M99" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value of the resonator are in quite reasonable agreement with the simulations, although some trends differ slightly. The slight deviation between the center frequency of the simulations and the experiment is most probably due to the non-perfect manufacturing of the surfaces, which leads to a decrease in the surface conductivity of the resonator material. Interestingly, the resonator features two very similar, distinct maxima in the <inline-formula><mml:math id="M100" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value at a coupling rod angle of <inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:mo>+</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>°. Since the magnitude of reflections at the dip center decreases (larger <inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mn mathvariant="normal">11</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>) and the <inline-formula><mml:math id="M104" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value decreases when the tilt angle gets smaller, the resonator must be in the overcoupled regime for all coupler positions (Table <xref ref-type="table" rid="Ch1.T1"/>). The <inline-formula><mml:math id="M105" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula> coefficient calculated from the voltage standing wave ratio (VSWR) (see Table <xref ref-type="table" rid="Ch1.T1"/> and Sect. S1) underlines that the resonator is not fully critically coupled (<inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:mi mathvariant="italic">β</mml:mi><mml:mo>≠</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>), with or without the sample tube. Both experiments and simulations show a consistent increase in <inline-formula><mml:math id="M107" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value for all coupler tilt angles upon inserting the quartz tube. This effect probably results from the tube acting as a dielectric ring that slightly pulls the electric field into the tube walls, as seen upon closer inspection of Figs. <xref ref-type="fig" rid="Ch1.F1"/>e and S4d. This, in turn, leads to a reduction in the electric field near the resonator walls. The coupler design tested here is, therefore, suitable for applications in CW EPR, although the coupling range is found to be less versatile compared to other published designs <xref ref-type="bibr" rid="bib1.bibx14" id="paren.26"/>. Additional simulations (not shown) demonstrate that the observed broadband absorption of around 4 dB in all curves can be explained by the losses introduced by the top part of the waveguide made out of stainless steel, which is used to reduce the heat flow from the flange at room temperature to the cold resonator; these losses can be strongly alleviated by silver coating of the waveguide's inner walls <xref ref-type="bibr" rid="bib1.bibx31 bib1.bibx12" id="paren.27"/>.</p>

<table-wrap id="Ch1.T1" specific-use="star"><label>Table 1</label><caption><p id="d1e1529">Microwave characteristics of the resonator. Experimental and simulated resonator mode for different coupler positions (tilt angle) with and without an empty 3 mm OD clear fused quartz tube. BW is bandwidth.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="10">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="right" colsep="1"/>
     <oasis:colspec colnum="7" colname="col7" align="right"/>
     <oasis:colspec colnum="8" colname="col8" align="right"/>
     <oasis:colspec colnum="9" colname="col9" align="right"/>
     <oasis:colspec colnum="10" colname="col10" align="right"/>
     <oasis:thead>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"/>
         <oasis:entry rowsep="1" namest="col3" nameend="col6" align="center" colsep="1">Without sample tube </oasis:entry>
         <oasis:entry rowsep="1" namest="col7" nameend="col10" align="center">With sample tube </oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Position</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mi mathvariant="normal">dip</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (GHz)</oasis:entry>
         <oasis:entry colname="col4">BW (MHz)</oasis:entry>
         <oasis:entry colname="col5"><inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col6"><inline-formula><mml:math id="M110" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col7"><inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">ν</mml:mi><mml:mi mathvariant="normal">dip</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (GHz)</oasis:entry>
         <oasis:entry colname="col8">BW (MHz)</oasis:entry>
         <oasis:entry colname="col9"><inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col10"><inline-formula><mml:math id="M113" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>°</oasis:entry>
         <oasis:entry colname="col3">35.648</oasis:entry>
         <oasis:entry colname="col4">24.5</oasis:entry>
         <oasis:entry colname="col5">1455</oasis:entry>
         <oasis:entry colname="col6">3.39</oasis:entry>
         <oasis:entry colname="col7">34.223</oasis:entry>
         <oasis:entry colname="col8">13.4</oasis:entry>
         <oasis:entry colname="col9">2554</oasis:entry>
         <oasis:entry colname="col10">2.71</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Experiment</oasis:entry>
         <oasis:entry colname="col2">0°</oasis:entry>
         <oasis:entry colname="col3">35.650</oasis:entry>
         <oasis:entry colname="col4">28.5</oasis:entry>
         <oasis:entry colname="col5">1251</oasis:entry>
         <oasis:entry colname="col6">4.41</oasis:entry>
         <oasis:entry colname="col7">34.222</oasis:entry>
         <oasis:entry colname="col8">16.4</oasis:entry>
         <oasis:entry colname="col9">2087</oasis:entry>
         <oasis:entry colname="col10">3.53</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M115" display="inline"><mml:mrow><mml:mo>+</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>°</oasis:entry>
         <oasis:entry colname="col3">35.653</oasis:entry>
         <oasis:entry colname="col4">21.5</oasis:entry>
         <oasis:entry colname="col5">1658</oasis:entry>
         <oasis:entry colname="col6">3.17</oasis:entry>
         <oasis:entry colname="col7">34.224</oasis:entry>
         <oasis:entry colname="col8">13.6</oasis:entry>
         <oasis:entry colname="col9">2517</oasis:entry>
         <oasis:entry colname="col10">2.89</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M116" display="inline"><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>°</oasis:entry>
         <oasis:entry colname="col3">35.619</oasis:entry>
         <oasis:entry colname="col4">19.0</oasis:entry>
         <oasis:entry colname="col5">1875</oasis:entry>
         <oasis:entry colname="col6">1.35</oasis:entry>
         <oasis:entry colname="col7">34.247</oasis:entry>
         <oasis:entry colname="col8">15.0</oasis:entry>
         <oasis:entry colname="col9">2283</oasis:entry>
         <oasis:entry colname="col10">1.55</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Simulation</oasis:entry>
         <oasis:entry colname="col2">0°</oasis:entry>
         <oasis:entry colname="col3">35.613</oasis:entry>
         <oasis:entry colname="col4">51.0</oasis:entry>
         <oasis:entry colname="col5">699</oasis:entry>
         <oasis:entry colname="col6">3.61</oasis:entry>
         <oasis:entry colname="col7">34.240</oasis:entry>
         <oasis:entry colname="col8">19.0</oasis:entry>
         <oasis:entry colname="col9">1802</oasis:entry>
         <oasis:entry colname="col10">1.17</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:mo>+</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:mrow></mml:math></inline-formula>°</oasis:entry>
         <oasis:entry colname="col3">35.615</oasis:entry>
         <oasis:entry colname="col4">21.0</oasis:entry>
         <oasis:entry colname="col5">1696</oasis:entry>
         <oasis:entry colname="col6">1.61</oasis:entry>
         <oasis:entry colname="col7">34.243</oasis:entry>
         <oasis:entry colname="col8">18.0</oasis:entry>
         <oasis:entry colname="col9">1902</oasis:entry>
         <oasis:entry colname="col10">1.08</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Microwave characteristics of the resonator</title>
      <p id="d1e1904">In order to assess the sensitivity of the EPR resonator, we quantify contributions to the EPR signal that characterize the resonator. The intensity of a CW EPR signal in the linear microwave power regime (no saturation) can be expressed as
            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M118" display="block"><mml:mrow><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub><mml:mi mathvariant="italic">η</mml:mi><mml:msqrt><mml:mrow><mml:mi>P</mml:mi><mml:mi>Z</mml:mi></mml:mrow></mml:msqrt><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>
          where <inline-formula><mml:math id="M119" display="inline"><mml:mi>S</mml:mi></mml:math></inline-formula> is the signal voltage at the end of the transmission line connected to the resonator, <inline-formula><mml:math id="M120" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">χ</mml:mi><mml:mrow><mml:mo>′</mml:mo><mml:mo>′</mml:mo></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> is the magnetic susceptibility of the sample, <inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the loaded quality factor of the resonator (see Eq. S2 in the Supplement), <inline-formula><mml:math id="M122" display="inline"><mml:mi mathvariant="italic">η</mml:mi></mml:math></inline-formula> is the filling factor as defined in Eq. (S5), <inline-formula><mml:math id="M123" display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula> is the microwave power, and <inline-formula><mml:math id="M124" display="inline"><mml:mi>Z</mml:mi></mml:math></inline-formula> is the characteristic impedance of the transmission line <xref ref-type="bibr" rid="bib1.bibx4" id="paren.28"/>. Equation (<xref ref-type="disp-formula" rid="Ch1.E1"/>) shows that the signal-to-noise ratio can be optimized by increasing <inline-formula><mml:math id="M125" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> or <inline-formula><mml:math id="M126" display="inline"><mml:mi mathvariant="italic">η</mml:mi></mml:math></inline-formula>; both parameters are influenced by the sample tube diameter <xref ref-type="bibr" rid="bib1.bibx20" id="paren.29"/>. Here, the diameter was not varied to maximize the sensitivity for this resonator due to the design goal of using the same sample tube size in multiple resonators across the three frequency bands (S, X, Q), for which a diameter of 3 mm is a suitable common denominator.</p>
      <p id="d1e2021">The loaded <inline-formula><mml:math id="M127" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value, <inline-formula><mml:math id="M128" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> (see Eq. S2), is a measure for the efficiency of the cavity (including the impedance matching (load) of the transmission line) in storing microwave energy versus dissipating energy, e.g., as ohmic losses. Accordingly, it can also be defined as the ratio between the energy stored in the resonator and the energy lost per cycle. The obtained <inline-formula><mml:math id="M129" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> value of 2550 (unloaded <inline-formula><mml:math id="M130" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mn mathvariant="normal">0</mml:mn></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">9475</mml:mn></mml:mrow></mml:math></inline-formula>; see Eq. S4) near critical coupling is on the higher end of previously reported values for home-built Q-band resonators based on the TE<inline-formula><mml:math id="M131" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> mode (see Table <xref ref-type="table" rid="Ch1.T2"/>); similar values were obtained by resonators with oversized sample tube diameters, e.g., 2.8 mm OD with a <inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> value of 2480 by <xref ref-type="bibr" rid="bib1.bibx14" id="text.30"/> and 3.0 mm OD with a <inline-formula><mml:math id="M133" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> value of 2600 by <xref ref-type="bibr" rid="bib1.bibx24" id="text.31"/>.</p>
      <p id="d1e2108">Although the introduction of an oversized lossy sample is expected to cause a reduction in the <inline-formula><mml:math id="M134" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value, the overall sensitivity can still be higher due to the larger sample volume, which implies a larger number of spins at a given concentration <xref ref-type="bibr" rid="bib1.bibx31" id="paren.32"/>. The increase in concentration sensitivity through the increased sample volume stems from a high filling factor <inline-formula><mml:math id="M135" display="inline"><mml:mi mathvariant="italic">η</mml:mi></mml:math></inline-formula> (defined in Eq. S5). Simulations show for the present Q-band TE<inline-formula><mml:math id="M136" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> resonator <inline-formula><mml:math id="M137" display="inline"><mml:mrow><mml:mi mathvariant="italic">η</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.057</mml:mn></mml:mrow></mml:math></inline-formula>, with a 5 mm high sample in a 3 mm OD clear fused quartz tube, which is considerably higher than for a TE<inline-formula><mml:math id="M138" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">102</mml:mn></mml:msub></mml:math></inline-formula> rectangular resonator with <inline-formula><mml:math id="M139" display="inline"><mml:mrow><mml:mi mathvariant="italic">η</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.023</mml:mn></mml:mrow></mml:math></inline-formula> (see Table <xref ref-type="table" rid="Ch1.T2"/>). For both resonators, the filling factors increase for samples with higher dielectric constants due to an increased concentration of the microwave mode in the cavity center (Table S3). Comparing the two cavities, the TE<inline-formula><mml:math id="M140" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> resonator shows a significant improvement in <inline-formula><mml:math id="M141" display="inline"><mml:mi mathvariant="italic">η</mml:mi></mml:math></inline-formula> due to better focusing of the microwave <inline-formula><mml:math id="M142" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field along the axis of the sample tube in the cylindrical cavity compared to the rectangular cavity. As a side effect, the resonance frequency of this high-<inline-formula><mml:math id="M143" display="inline"><mml:mi mathvariant="italic">η</mml:mi></mml:math></inline-formula> cavity is more susceptible to changes in the sample position compared to the TE<inline-formula><mml:math id="M144" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">102</mml:mn></mml:msub></mml:math></inline-formula> resonator (Fig. <xref ref-type="fig" rid="Ch1.F2"/>a) because the sample diameter is of similar size as the wavelength, and a high proportion of the microwave field interacts with the sample (Fig. <xref ref-type="fig" rid="Ch1.F1"/>).</p>
      <p id="d1e2221">Ultimately, the signal intensity is driven by the strength of the <inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> field. The relation between the applied power (Eq. <xref ref-type="disp-formula" rid="Ch1.E1"/>) and <inline-formula><mml:math id="M146" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> is defined as the conversion factor (<inline-formula><mml:math id="M147" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula>):
            <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M148" display="block"><mml:mrow><mml:mi>C</mml:mi><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow><mml:msqrt><mml:mi>P</mml:mi></mml:msqrt></mml:mfrac></mml:mstyle><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>
          <inline-formula><mml:math id="M149" display="inline"><mml:mrow><mml:msub><mml:mi>B</mml:mi><mml:mn mathvariant="normal">1</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> can be calculated from the length of a <inline-formula><mml:math id="M150" display="inline"><mml:mi mathvariant="italic">π</mml:mi></mml:math></inline-formula> pulse in a Rabi nutation experiment. For a <inline-formula><mml:math id="M151" display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula>-irradiated Herasil sample at room temperature and at 50 K, pulse nutation experiments show <inline-formula><mml:math id="M152" display="inline"><mml:mi mathvariant="italic">π</mml:mi></mml:math></inline-formula> pulse lengths of 46 and 44 ns (Fig. S5), corresponding to conversion factors of 0.45 and 0.52 mT <inline-formula><mml:math id="M153" display="inline"><mml:mrow><mml:msup><mml:msqrt><mml:mi>W</mml:mi></mml:msqrt><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, respectively, similarly to previously published resonators  (see Table <xref ref-type="table" rid="Ch1.T2"/>). These experimental values are in good agreement with the calculated conversion factor of 0.55 mT <inline-formula><mml:math id="M154" display="inline"><mml:mrow><mml:msup><mml:msqrt><mml:mi>W</mml:mi></mml:msqrt><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, determined from the simulated magnetic field strength in the center of the cavity with an empty 3 mm quartz tube. The nutation experiments further show that the resonator is also suitable for single-frequency pulsed EPR experiments. However, given the elevated <inline-formula><mml:math id="M155" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value of the resonator, it is advantageous to use low-power and more selective pulses when a shorter spectrometer dead time is required.</p>

<table-wrap id="Ch1.T2" specific-use="star"><label>Table 2</label><caption><p id="d1e2355">Comparison of microwave characteristics with resonators from the literature.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="6">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="right"/>
     <oasis:colspec colnum="3" colname="col3" align="right"/>
     <oasis:colspec colnum="4" colname="col4" align="right"/>
     <oasis:colspec colnum="5" colname="col5" align="right"/>
     <oasis:colspec colnum="6" colname="col6" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Resonator type</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:msup><mml:mi mathvariant="italic">η</mml:mi><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col4"><inline-formula><mml:math id="M165" display="inline"><mml:mi>C</mml:mi></mml:math></inline-formula> in mT <inline-formula><mml:math id="M166" display="inline"><mml:mrow><mml:msup><mml:msqrt><mml:mi mathvariant="normal">W</mml:mi></mml:msqrt><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col5">Tube diameter</oasis:entry>
         <oasis:entry colname="col6">Reference</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">TE<inline-formula><mml:math id="M167" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">2080–2550</oasis:entry>
         <oasis:entry colname="col3">0.057</oasis:entry>
         <oasis:entry colname="col4">0.45–0.52</oasis:entry>
         <oasis:entry colname="col5">3 mm</oasis:entry>
         <oasis:entry colname="col6">This work</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">TE<inline-formula><mml:math id="M168" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">450–950</oasis:entry>
         <oasis:entry colname="col3">n.d.</oasis:entry>
         <oasis:entry colname="col4">0.009</oasis:entry>
         <oasis:entry colname="col5">4 mm</oasis:entry>
         <oasis:entry colname="col6">
                    <xref ref-type="bibr" rid="bib1.bibx11" id="text.33"/>
                  </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">TE<inline-formula><mml:math id="M169" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">1300–2600<inline-formula><mml:math id="M170" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">n.d.</oasis:entry>
         <oasis:entry colname="col4">0.45</oasis:entry>
         <oasis:entry colname="col5">3 mm</oasis:entry>
         <oasis:entry colname="col6">
                    <xref ref-type="bibr" rid="bib1.bibx24" id="text.34"/>
                  </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">TE<inline-formula><mml:math id="M171" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">102</mml:mn></mml:msub></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">200–400<inline-formula><mml:math id="M172" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">0.023</oasis:entry>
         <oasis:entry colname="col4">0.11</oasis:entry>
         <oasis:entry colname="col5">2.9 mm</oasis:entry>
         <oasis:entry colname="col6">
                    <xref ref-type="bibr" rid="bib1.bibx31" id="text.35"/>
                  </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Loop gap<inline-formula><mml:math id="M173" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">250–700</oasis:entry>
         <oasis:entry colname="col3">n.d.</oasis:entry>
         <oasis:entry colname="col4">0.39–1.7</oasis:entry>
         <oasis:entry colname="col5">0.4–1.6 mm</oasis:entry>
         <oasis:entry colname="col6">
                    <xref ref-type="bibr" rid="bib1.bibx7" id="text.36"/>
                  </oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table><table-wrap-foot><p id="d1e2358"><inline-formula><mml:math id="M156" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">a</mml:mi></mml:msup></mml:math></inline-formula> Empty 3 mm tube; n.d. stands for not determined. Ranges of <inline-formula><mml:math id="M157" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> values span the range from overcoupled to critically coupled. <inline-formula><mml:math id="M158" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">b</mml:mi></mml:msup></mml:math></inline-formula> Ranges are over several overcoupled three-loop, two-gap resonators. Note that <inline-formula><mml:math id="M159" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi mathvariant="normal">L</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and the conversion factor also depend on dielectric losses in a particular sample. <inline-formula><mml:math id="M160" display="inline"><mml:msup><mml:mi/><mml:mi mathvariant="normal">c</mml:mi></mml:msup></mml:math></inline-formula> Note that higher <inline-formula><mml:math id="M161" display="inline"><mml:mi mathvariant="italic">η</mml:mi></mml:math></inline-formula> values are found for samples with <inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:mi mathvariant="italic">ϵ</mml:mi><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula> (see Table S3).</p></table-wrap-foot></table-wrap>

      <fig id="Ch1.F4" specific-use="star"><label>Figure 4</label><caption><p id="d1e2693">Q-band CW EPR spectra of a multi-component Ti(III)-complex system in toluene at 30 K <bold>(a)</bold> and at room temperature <bold>(b)</bold> and spectrum of 10 ppm N@C<inline-formula><mml:math id="M174" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula> spin-diluted in C<inline-formula><mml:math id="M175" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula> at room temperature <bold>(c)</bold>. The latter was measured on an extended powder sample (ca. 8 mm) with a modulation amplitude of 2 <inline-formula><mml:math id="M176" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>T and shows a line width of 10 <inline-formula><mml:math id="M177" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>T.</p></caption>
          <graphic xlink:href="https://mr.copernicus.org/articles/5/143/2024/mr-5-143-2024-f04.png"/>

        </fig>

</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>CW EPR performance of the resonator</title>
      <p id="d1e2754">To demonstrate the sensitivity and spectral resolution of the Q-band resonator on relevant systems for current research applications, we measured room-temperature and low-temperature (30 K) CW EPR spectra of a homogeneous Ti(III) catalyst in toluene (Fig. <xref ref-type="fig" rid="Ch1.F4"/>). The Q-band CW EPR spectrum is an important complement to S-band and X-band spectra to resolve the different overlapping Ti(III) species present in this system with only slightly different <inline-formula><mml:math id="M178" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula>-tensor values. In the room-temperature Q-band CW EPR spectrum (Fig. <xref ref-type="fig" rid="Ch1.F4"/>b), three major components could be readily identified. In the low-temperature spectrum, in the absence of motional averaging, the full <inline-formula><mml:math id="M179" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula> anisotropy of the different components is observed. As discussed above, for echo-detected field-swept EPR spectra, the potential dependence of relative signal intensities on the magnetic field complicates global fitting with spectra in other frequency bands and hence hampers a quantitative analysis. In the case at hand, with the two Q-band CW EPR spectra, the <inline-formula><mml:math id="M180" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula> tensors of the three main components become sufficiently constrained. Together with the hyperfine couplings to surrounding nuclei, which are more clearly visible in the lower-frequency spectra, we established multi-frequency CW EPR analysis in the S, X, and Q bands on the same sample tube as an essential step to deconvolute overlapping spectral components and to understand the catalytic mechanism of this class of systems.</p>
      <p id="d1e2782">The resonator was also tested with spin-diluted N@C<inline-formula><mml:math id="M181" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula>, as shown in Fig. <xref ref-type="fig" rid="Ch1.F4"/>c. In this sample, atomic nitrogen (<inline-formula><mml:math id="M182" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">3</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M183" display="inline"><mml:mrow><mml:mi>I</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>) is trapped in the center of the fullerene C<inline-formula><mml:math id="M184" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula>, which renders the <inline-formula><mml:math id="M185" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula> tensor and the hyperfine coupling to the nitrogen very isotropic <xref ref-type="bibr" rid="bib1.bibx1 bib1.bibx33 bib1.bibx34" id="paren.37"/>. In the room-temperature Q-band CW EPR spectrum recorded with a single scan, one can observe three lines due to the <inline-formula><mml:math id="M186" display="inline"><mml:msup><mml:mi/><mml:mn mathvariant="normal">14</mml:mn></mml:msup></mml:math></inline-formula>N hyperfine coupling, with each of the lines having a peak-to-peak line width of 0.01 mT. The spectra of the Ti(III) catalyst and N@C<inline-formula><mml:math id="M187" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula> samples demonstrate the suitability of the resonator for applications from cryogenic to room temperature for samples with narrow and broad lines. Furthermore, a power saturation curve of TEMPOL radicals (100 <inline-formula><mml:math id="M188" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>M, 20 <inline-formula><mml:math id="M189" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>L) in frozen toluene solution demonstrates the onset and progressive saturation of the sample and shows a signal-to-noise ratio of 235 in a single scan (Fig. S6).</p>
</sec>
</sec>
<sec id="Ch1.S4" sec-type="conclusions">
  <label>4</label><title>Conclusions</title>
      <p id="d1e2887">In this work, we introduced the design and fabrication of a 35 GHz cavity resonator for oversized samples and evaluated its performance in CW EPR and low-power pulsed EPR. The cylindrical resonator employs the TE<inline-formula><mml:math id="M190" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:math></inline-formula> mode and features a high filling factor of <inline-formula><mml:math id="M191" display="inline"><mml:mrow><mml:mi mathvariant="italic">η</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0.057</mml:mn></mml:mrow></mml:math></inline-formula> that increases for high-dielectric samples and a high loaded <inline-formula><mml:math id="M192" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value of around 2550 when near critical coupling or shows an overcoupled bandwidth of about 25 MHz with a 3 mm OD clear fused quartz tube. Electromagnetic field calculations are in good agreement with the experiments, highlighting the importance of rational resonator design and simulations as tools for geometry optimization. For the resonator, a high resolution was demonstrated with a linewidth of 10 <inline-formula><mml:math id="M193" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi></mml:mrow></mml:math></inline-formula>T for N@C<inline-formula><mml:math id="M194" display="inline"><mml:msub><mml:mi/><mml:mn mathvariant="normal">60</mml:mn></mml:msub></mml:math></inline-formula>. A Ti(III) catalyst with multiple spectral species was employed to demonstrate the general applicability of the probe head and its operation at cryogenic temperatures, as well as the benefit of resolving spectral overlap in complex systems. This resonator is, therefore, well-suited for CW EPR and also for single-frequency pulsed EPR experiments. Since the construction of the resonator is straightforward due to its simplistic and robust design, we hope that it will be leveraged to enhance the use of the Q band in multi-frequency EPR analyses.</p>
</sec>

      
      </body>
    <back><notes notes-type="dataavailability"><title>Data availability</title>

      <p id="d1e2940">Design 3D CAD data are made available via Zenodo with <ext-link xlink:href="https://doi.org/10.5281/zenodo.11082486" ext-link-type="DOI">10.5281/zenodo.11082486</ext-link> <xref ref-type="bibr" rid="bib1.bibx6" id="paren.38"/>.</p>
  </notes><app-group>
        <supplementary-material position="anchor"><p id="d1e2949">The supplement related to this article is available online at: <inline-supplementary-material xlink:href="https://doi.org/10.5194/mr-5-143-2024-supplement" xlink:title="pdf">https://doi.org/10.5194/mr-5-143-2024-supplement</inline-supplementary-material>.</p></supplementary-material>
        </app-group><notes notes-type="authorcontribution"><title>Author contributions</title>

      <p id="d1e2958">DK conceived the project and data processing. JS and JWAF performed the experimental work and data processing. RT and DK designed the resonator. RT performed the simulations analyzed by RT and DK. OO fabricated the resonator. NA, ABB, MI, and KM provided relevant test samples. JS, JWAF, RT, and DK wrote the paper with inputs from all authors. All authors discussed the results and contributed to the final paper.</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d1e2964">The contact author has declared that none of the authors has any competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d1e2970">Publisher’s note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. While Copernicus Publications makes every effort to include appropriate place names, the final responsibility lies with the authors.</p>
  </notes><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d1e2977">This research has been supported by the ETH research grant (no. ETH-35221) to Daniel Klose and the SNSF grant (no. 200021_201070/1) to Alexander Benjamin Barnes.</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d1e2983">This paper was edited by Daniella Goldfarb and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Almeida Murphy et al.(1996)</label><mixed-citation>Almeida Murphy, T., Pawlik, T., Weidinger, A., Höhne, M., Alcala, R., and Spaeth, J.-M.: Observation of Atomlike Nitrogen-Implanted Solid C60, Phys. Rev. Lett., 77, 1075–1078, <ext-link xlink:href="https://doi.org/10.1103/PhysRevLett.77.1075" ext-link-type="DOI">10.1103/PhysRevLett.77.1075</ext-link>, 1996.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Bonke et al.(2021)</label><mixed-citation>Bonke, S. A., Risse, T., Schnegg, A., and Brückner, A.: In situ electron paramagnetic resonance spectroscopy for catalysis, Nature Reviews Methods Primers, 1, 33, <ext-link xlink:href="https://doi.org/10.1038/s43586-021-00031-4" ext-link-type="DOI">10.1038/s43586-021-00031-4</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>Denysenkov et al.(2017)</label><mixed-citation>Denysenkov, V., van Os, P., and Prisner, T. F.: Q-Band Loop-Gap Resonator for EPR Applications with Broadband-Shaped Pulses, Appl. Magn. Reson., 48, 1263–1272, <ext-link xlink:href="https://doi.org/10.1007/s00723-017-0930-9" ext-link-type="DOI">10.1007/s00723-017-0930-9</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Eaton et al.(2010)</label><mixed-citation>Eaton, G. R., Eaton, S. S., Barr, D. P., and Weber, R. T.: Quantitative EPR, Springer Vienna, ISBN 9783211929483, <ext-link xlink:href="https://doi.org/10.1007/978-3-211-92948-3" ext-link-type="DOI">10.1007/978-3-211-92948-3</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>Eckardt et al.(2015)</label><mixed-citation>Eckardt, M., Wieczorek, R., and Harneit, W.: Stability of C60 and N@C60 under thermal and optical exposure, Carbon, 95, 601–607, <ext-link xlink:href="https://doi.org/10.1016/j.carbon.2015.08.073" ext-link-type="DOI">10.1016/j.carbon.2015.08.073</ext-link>, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx6"><label>Fischer et al.(2024)</label><mixed-citation>Fischer, J. W. A., Stropp, J., Tschaggelar, R., Oberhänsli, O., Alaniva, N., Inoue, M., Mashima, K., Barnes, A. B., Jeschke, G., and Klose, D.: Design 3D CAD data of an oversized-sample 35 GHz EPR resonator with an elevated <inline-formula><mml:math id="M195" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> value, Zenodo [data set], <ext-link xlink:href="https://doi.org/10.5281/zenodo.11082486" ext-link-type="DOI">10.5281/zenodo.11082486</ext-link>, 2024.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Forrer et al.(2008)</label><mixed-citation>Forrer, J., García-Rubio, I., Schuhmam, R., Tschaggelar, R., and Harmer, J.: Cryogenic Q-band (35GHz) probehead featuring large excitation microwave fields for pulse and continuous wave electron paramagnetic resonance spectroscopy: Performance and applications, J. Magn. Reson., 190, 280–291, <ext-link xlink:href="https://doi.org/10.1016/j.jmr.2007.11.009" ext-link-type="DOI">10.1016/j.jmr.2007.11.009</ext-link>, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Franco et al.(2006)</label><mixed-citation>Franco, L., Ceola, S., Corvaja, C., Bolzonella, S., Harneit, W., and Maggini, M.: Synthesis and magnetic properties of N@C60 derivatives, Chem. Phys. Lett., 422, 100–105, <ext-link xlink:href="https://doi.org/10.1016/j.cplett.2006.02.046" ext-link-type="DOI">10.1016/j.cplett.2006.02.046</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Froncisz and Hyde(1982)</label><mixed-citation>Froncisz, W. and Hyde, J. S.: The loop-gap resonator: a new microwave lumped circuit ESR sample structure, J. Magn. Reson., 47, 515–521, <ext-link xlink:href="https://doi.org/10.1016/0022-2364(82)90221-9" ext-link-type="DOI">10.1016/0022-2364(82)90221-9</ext-link>, 1982.</mixed-citation></ref>
      <ref id="bib1.bibx10"><label>Gromov et al.(2001)</label><mixed-citation>Gromov, I., Shane, J., Forrer, J., Rakhmatoullin, R., Rozentzwaig, Y., and Schweiger, A.: A Q-Band Pulse EPR/ENDOR Spectrometer and the Implementation of Advanced One- and Two-Dimensional Pulse EPR Methodology, J. Magn. Reson., 149, 196–203, <ext-link xlink:href="https://doi.org/10.1006/jmre.2001.2298" ext-link-type="DOI">10.1006/jmre.2001.2298</ext-link>, 2001.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Gromov et al.(2006)</label><mixed-citation>Gromov, I., Forrer, J., and Schweiger, A.: Probehead operating at 35GHz for continuous wave and pulse electron paramagnetic resonance applications, Rev. Sci. Instrum., 77, 064704, <ext-link xlink:href="https://doi.org/10.1063/1.2216849" ext-link-type="DOI">10.1063/1.2216849</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>Himmler et al.(2022)</label><mixed-citation>Himmler, A., Albannay, M. M., von Witte, G., Kozerke, S., and Ernst, M.: Electroplated waveguides to enhance DNP and EPR spectra of silicon and diamond particles, Magn. Reson., 3, 203–209, <ext-link xlink:href="https://doi.org/10.5194/mr-3-203-2022" ext-link-type="DOI">10.5194/mr-3-203-2022</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Jakes et al.(2003)</label><mixed-citation>Jakes, P., Dinse, K.-P., Meyer, C., Harneit, W., and Weidinger, A.: Purification and optical spectroscopy of N@C60, Phys. Chem. Chem. Phys., 5, 4080, <ext-link xlink:href="https://doi.org/10.1039/b308284a" ext-link-type="DOI">10.1039/b308284a</ext-link>, 2003.</mixed-citation></ref>
      <ref id="bib1.bibx14"><label>Judd et al.(2022)</label><mixed-citation>Judd, M., Jolley, G., Suter, D., Cox, N., and Savitsky, A.: Dielectric Coupler for General Purpose Q-Band EPR Cavity, Appl. Magn. Reson., 53, 963–977, <ext-link xlink:href="https://doi.org/10.1007/s00723-021-01404-4" ext-link-type="DOI">10.1007/s00723-021-01404-4</ext-link>, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx15"><label>Matzler and Wegmuller(1987)</label><mixed-citation>Matzler, C. and Wegmuller, U.: Dielectric properties of freshwater ice at microwave frequencies, J. Phys. D Appl. Phys., 20, 1623, <ext-link xlink:href="https://doi.org/10.1088/0022-3727/20/12/013" ext-link-type="DOI">10.1088/0022-3727/20/12/013</ext-link>, 1987.</mixed-citation></ref>
      <ref id="bib1.bibx16"><label>Mett and Hyde(2004)</label><mixed-citation>Mett, R. R. and Hyde, J. S.: Microwave leakage from field modulation slots in TE011 electron paramagnetic resonance cavities, Rev. Sci. Instrum., 76, 014702, <ext-link xlink:href="https://doi.org/10.1063/1.1823748" ext-link-type="DOI">10.1063/1.1823748</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bibx17"><label>Mett et al.(2009)</label><mixed-citation>Mett, R. R., Sidabras, J. W., and Hyde, J. S.: Coupling of waveguide and resonator by inductive and capacitive irises for EPR spectroscopy, Appl. Magn. Reson., 35, 285–318, <ext-link xlink:href="https://doi.org/10.1007/s00723-008-0162-0" ext-link-type="DOI">10.1007/s00723-008-0162-0</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx18"><label>Misra(2011)</label><mixed-citation>Misra, M.: Multifrequency Electron Paramagnetic Resonance: Theory and Applications, Wiley, ISBN 9783527633531, <ext-link xlink:href="https://doi.org/10.1002/9783527633531" ext-link-type="DOI">10.1002/9783527633531</ext-link>, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx19"><label>NejatyJahromy et al.(2021)</label><mixed-citation>NejatyJahromy, Y., Roy, S. C., Glaum, R., and Schiemann, O.: Multi-Frequency and Single-Crystal EPR on V4+ in W-Doped <inline-formula><mml:math id="M196" display="inline"><mml:mi mathvariant="italic">β</mml:mi></mml:math></inline-formula>-Vanadyl(V) Phosphate: Hyperfine Coupling- and <inline-formula><mml:math id="M197" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula>-Tensor Values and Orientation, Appl. Magn. Reson., 52, 169–175, <ext-link xlink:href="https://doi.org/10.1007/s00723-020-01303-0" ext-link-type="DOI">10.1007/s00723-020-01303-0</ext-link>, 2021.</mixed-citation></ref>
      <ref id="bib1.bibx20"><label>Nesmelov et al.(2004)</label><mixed-citation>Nesmelov, Y. E., Gopinath, A., and Thomas, D. D.: Aqueous sample in an EPR cavity: sensitivity considerations, J. Magn. Reson., 167, 138–146, <ext-link xlink:href="https://doi.org/10.1016/j.jmr.2003.12.005" ext-link-type="DOI">10.1016/j.jmr.2003.12.005</ext-link>, 2004.</mixed-citation></ref>
      <ref id="bib1.bibx21"><label>Polyhach et al.(2012)</label><mixed-citation>Polyhach, Y., Bordignon, E., Tschaggelar, R., Gandra, S., Godt, A., and Jeschke, G.: High sensitivity and versatility of the DEER experiment on nitroxide radical pairs at Q-band frequencies, Phys. Chem. Chem. Phys., 14, 10762, <ext-link xlink:href="https://doi.org/10.1039/c2cp41520h" ext-link-type="DOI">10.1039/c2cp41520h</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx22"><label>Raitsimring et al.(2012)</label><mixed-citation>Raitsimring, A., Astashkin, A., Enemark, J. H., Blank, A., Twig, Y., Song, Y., and Meade, T. J.: Dielectric Resonator for K<inline-formula><mml:math id="M198" display="inline"><mml:msub><mml:mi/><mml:mi>a</mml:mi></mml:msub></mml:math></inline-formula>-Band Pulsed EPR Measurements at Cryogenic Temperatures: Probehead Construction and Applications, Appl. Magn. Reson., 42, 441–452, <ext-link xlink:href="https://doi.org/10.1007/s00723-012-0313-1" ext-link-type="DOI">10.1007/s00723-012-0313-1</ext-link>, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx23"><label>Reijerse and Savitsky(2017)</label><mixed-citation>Reijerse, E. and Savitsky, A.: Electron Paramagnetic Resonance Instrumentation, eMagRes, 6, 187–206, <ext-link xlink:href="https://doi.org/10.1002/9780470034590.emrstm1511" ext-link-type="DOI">10.1002/9780470034590.emrstm1511</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx24"><label>Reijerse et al.(2012)</label><mixed-citation>Reijerse, E., Lendzian, F., Isaacson, R., and Lubitz, W.: A tunable general purpose Q-band resonator for CW and pulse EPR/ENDOR experiments with large sample access and optical excitation, J. Magn. Reson., 214, 237–243, <ext-link xlink:href="https://doi.org/10.1016/j.jmr.2011.11.011" ext-link-type="DOI">10.1016/j.jmr.2011.11.011</ext-link>, 2012. </mixed-citation></ref>
      <ref id="bib1.bibx25"><label>Roessler and Salvadori(2018)</label><mixed-citation>Roessler, M. M. and Salvadori, E.: Principles and applications of EPR spectroscopy in the chemical sciences, Chem. Soc. Rev., 47, 2534–2553, <ext-link xlink:href="https://doi.org/10.1039/c6cs00565a" ext-link-type="DOI">10.1039/c6cs00565a</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx26"><label>Savitsky et al.(2013)</label><mixed-citation>Savitsky, A., Grishin, Y., Rakhmatullin, R., Reijerse, E., and Lubitz, W.: An improved coupling design for high-frequency TE011 electron paramagnetic resonance cavities, Rev. Sci. Instrum., 84, 014704, <ext-link xlink:href="https://doi.org/10.1063/1.4788735" ext-link-type="DOI">10.1063/1.4788735</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx27"><label>Schweiger and Jeschke(2001)</label><mixed-citation>Schweiger, A. and Jeschke, G.: Principles of Pulse Electron Paramagnetic Resonance, Oxford University Press, ISBN 9780198506348, <ext-link xlink:href="https://doi.org/10.1093/oso/9780198506348.001.0001" ext-link-type="DOI">10.1093/oso/9780198506348.001.0001</ext-link>, 2001.</mixed-citation></ref>
      <ref id="bib1.bibx28"><label>Sidabras et al.(2017)</label><mixed-citation>Sidabras, J. W., Richie, J. E., and Hyde, J. S.: Axially uniform magnetic field-modulation excitation for electron paramagnetic resonance in rectangular and cylindrical cavities by slot cutting, J. Magn. Reson., 274, 115–124, <ext-link xlink:href="https://doi.org/10.1016/j.jmr.2016.11.014" ext-link-type="DOI">10.1016/j.jmr.2016.11.014</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx29"><label>Sienkiewicz et al.(1996)</label><mixed-citation>Sienkiewicz, A., Smith, B. G., Veselov, A., and Scholes, C. P.: Tunable Q-band resonator for low temperature electron paramagnetic resonance/electron nuclear double resonance measurements, Rev. Sci. Instrum., 67, 2134–2138, <ext-link xlink:href="https://doi.org/10.1063/1.1147027" ext-link-type="DOI">10.1063/1.1147027</ext-link>, 1996.</mixed-citation></ref>
      <ref id="bib1.bibx30"><label>Stoll and Schweiger(2006)</label><mixed-citation>Stoll, S. and Schweiger, A.: EasySpin, a comprehensive software package for spectral simulation and analysis in EPR, J. Magn. Reson., 178, 42–55, <ext-link xlink:href="https://doi.org/10.1016/j.jmr.2005.08.013" ext-link-type="DOI">10.1016/j.jmr.2005.08.013</ext-link>, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx31"><label>Tschaggelar et al.(2009)</label><mixed-citation>Tschaggelar, R., Kasumaj, B., Santangelo, M. G., Forrer, J., Leger, P., Dube, H., Diederich, F., Harmer, J., Schuhmann, R., García-Rubio, I., and Jeschke, G.: Cryogenic 35GHz pulse ENDOR probehead accommodating large sample sizes: Performance and applications, J. Magn. Reson., 200, 81–87, <ext-link xlink:href="https://doi.org/10.1016/j.jmr.2009.06.007" ext-link-type="DOI">10.1016/j.jmr.2009.06.007</ext-link>, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx32"><label>Tschaggelar et al.(2017)</label><mixed-citation>Tschaggelar, R., Breitgoff, F. D., Oberhänsli, O., Qi, M., Godt, A., and Jeschke, G.: High-Bandwidth Q-Band EPR Resonators, Appl. Magn. Reson., 48, 1273–1300, <ext-link xlink:href="https://doi.org/10.1007/s00723-017-0956-z" ext-link-type="DOI">10.1007/s00723-017-0956-z</ext-link>, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx33"><label>Weidinger et al.(1998)</label><mixed-citation>Weidinger, A., Waiblinger, M., Pietzak, B., and Almeida Murphy, T.: Atomic nitrogen in C60:N@C60, Appl. Phys. A-Mater., 66, 287–292, <ext-link xlink:href="https://doi.org/10.1007/s003390050668" ext-link-type="DOI">10.1007/s003390050668</ext-link>, 1998.</mixed-citation></ref>
      <ref id="bib1.bibx34"><label>Wittmann et al.(2018)</label><mixed-citation>Wittmann, J., Can, T., Eckardt, M., Harneit, W., Griffin, R., and Corzilius, B.: High-precision measurement of the electron spin <inline-formula><mml:math id="M199" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula> factor of trapped atomic nitrogen in the endohedral fullerene N@C60, J. Magn. Reson., 290, 12–17, <ext-link xlink:href="https://doi.org/10.1016/j.jmr.2018.02.019" ext-link-type="DOI">10.1016/j.jmr.2018.02.019</ext-link>, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx35"><label>Zhang et al.(2010)</label><mixed-citation>Zhang, Z., Fleissner, M. R., Tipikin, D. S., Liang, Z., Moscicki, J. K., Earle, K. A., Hubbell, W. L., and Freed, J. H.: Multifrequency Electron Spin Resonance Study of the Dynamics of Spin Labeled T4 Lysozyme, J. Phys. Chem. B, 114, 5503–5521, <ext-link xlink:href="https://doi.org/10.1021/jp910606h" ext-link-type="DOI">10.1021/jp910606h</ext-link>, 2010.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Design and performance of an oversized-sample  35&thinsp;GHz EPR resonator with an elevated <i>Q</i> value</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>Almeida Murphy et al.(1996)</label><mixed-citation>
      
Almeida Murphy, T., Pawlik, T., Weidinger, A., Höhne, M., Alcala, R., and
Spaeth, J.-M.: Observation of Atomlike Nitrogen-Implanted Solid C60, Phys.
Rev. Lett., 77, 1075–1078, <a href="https://doi.org/10.1103/PhysRevLett.77.1075" target="_blank">https://doi.org/10.1103/PhysRevLett.77.1075</a>, 1996.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Bonke et al.(2021)</label><mixed-citation>
      
Bonke, S. A., Risse, T., Schnegg, A., and Brückner, A.: In situ electron
paramagnetic resonance spectroscopy for catalysis, Nature Reviews Methods
Primers, 1, 33, <a href="https://doi.org/10.1038/s43586-021-00031-4" target="_blank">https://doi.org/10.1038/s43586-021-00031-4</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Denysenkov et al.(2017)</label><mixed-citation>
      
Denysenkov, V., van Os, P., and Prisner, T. F.: Q-Band Loop-Gap Resonator for
EPR Applications with Broadband-Shaped Pulses, Appl. Magn. Reson., 48,
1263–1272, <a href="https://doi.org/10.1007/s00723-017-0930-9" target="_blank">https://doi.org/10.1007/s00723-017-0930-9</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Eaton et al.(2010)</label><mixed-citation>
      
Eaton, G. R., Eaton, S. S., Barr, D. P., and Weber, R. T.: Quantitative EPR,
Springer Vienna, ISBN 9783211929483, <a href="https://doi.org/10.1007/978-3-211-92948-3" target="_blank">https://doi.org/10.1007/978-3-211-92948-3</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Eckardt et al.(2015)</label><mixed-citation>
      
Eckardt, M., Wieczorek, R., and Harneit, W.: Stability of C60 and N@C60 under
thermal and optical exposure, Carbon, 95, 601–607,
<a href="https://doi.org/10.1016/j.carbon.2015.08.073" target="_blank">https://doi.org/10.1016/j.carbon.2015.08.073</a>, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Fischer et al.(2024)</label><mixed-citation>
      
Fischer, J. W. A., Stropp, J., Tschaggelar, R., Oberhänsli, O., Alaniva, N., Inoue, M., Mashima, K., Barnes, A. B., Jeschke, G., and Klose, D.: Design 3D CAD data of an oversized-sample 35&thinsp;GHz EPR resonator with an elevated <i>Q</i> value, Zenodo [data set], <a href="https://doi.org/10.5281/zenodo.11082486" target="_blank">https://doi.org/10.5281/zenodo.11082486</a>, 2024.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Forrer et al.(2008)</label><mixed-citation>
      
Forrer, J., García-Rubio, I., Schuhmam, R., Tschaggelar, R., and Harmer, J.:
Cryogenic Q-band (35GHz) probehead featuring large excitation microwave
fields for pulse and continuous wave electron paramagnetic resonance
spectroscopy: Performance and applications, J. Magn. Reson., 190, 280–291,
<a href="https://doi.org/10.1016/j.jmr.2007.11.009" target="_blank">https://doi.org/10.1016/j.jmr.2007.11.009</a>, 2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Franco et al.(2006)</label><mixed-citation>
      
Franco, L., Ceola, S., Corvaja, C., Bolzonella, S., Harneit, W., and Maggini,
M.: Synthesis and magnetic properties of N@C60 derivatives, Chem. Phys.
Lett., 422, 100–105, <a href="https://doi.org/10.1016/j.cplett.2006.02.046" target="_blank">https://doi.org/10.1016/j.cplett.2006.02.046</a>, 2006.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Froncisz and Hyde(1982)</label><mixed-citation>
      
Froncisz, W. and Hyde, J. S.: The loop-gap resonator: a new microwave lumped
circuit ESR sample structure, J. Magn. Reson., 47, 515–521,
<a href="https://doi.org/10.1016/0022-2364(82)90221-9" target="_blank">https://doi.org/10.1016/0022-2364(82)90221-9</a>, 1982.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Gromov et al.(2001)</label><mixed-citation>
      
Gromov, I., Shane, J., Forrer, J., Rakhmatoullin, R., Rozentzwaig, Y., and
Schweiger, A.: A Q-Band Pulse EPR/ENDOR Spectrometer and the
Implementation of Advanced One- and Two-Dimensional Pulse EPR
Methodology, J. Magn. Reson., 149, 196–203, <a href="https://doi.org/10.1006/jmre.2001.2298" target="_blank">https://doi.org/10.1006/jmre.2001.2298</a>,
2001.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Gromov et al.(2006)</label><mixed-citation>
      
Gromov, I., Forrer, J., and Schweiger, A.: Probehead operating at 35GHz for
continuous wave and pulse electron paramagnetic resonance applications, Rev.
Sci. Instrum., 77, 064704, <a href="https://doi.org/10.1063/1.2216849" target="_blank">https://doi.org/10.1063/1.2216849</a>, 2006.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Himmler et al.(2022)</label><mixed-citation>
      
Himmler, A., Albannay, M. M., von Witte, G., Kozerke, S., and Ernst, M.: Electroplated waveguides to enhance DNP and EPR spectra of silicon and diamond particles, Magn. Reson., 3, 203–209, <a href="https://doi.org/10.5194/mr-3-203-2022" target="_blank">https://doi.org/10.5194/mr-3-203-2022</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Jakes et al.(2003)</label><mixed-citation>
      
Jakes, P., Dinse, K.-P., Meyer, C., Harneit, W., and Weidinger, A.:
Purification and optical spectroscopy of N@C60, Phys. Chem. Chem. Phys., 5,
4080, <a href="https://doi.org/10.1039/b308284a" target="_blank">https://doi.org/10.1039/b308284a</a>, 2003.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Judd et al.(2022)</label><mixed-citation>
      
Judd, M., Jolley, G., Suter, D., Cox, N., and Savitsky, A.: Dielectric Coupler
for General Purpose Q-Band EPR Cavity, Appl. Magn. Reson., 53, 963–977,
<a href="https://doi.org/10.1007/s00723-021-01404-4" target="_blank">https://doi.org/10.1007/s00723-021-01404-4</a>, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Matzler and Wegmuller(1987)</label><mixed-citation>
      
Matzler, C. and Wegmuller, U.: Dielectric properties of freshwater ice at
microwave frequencies, J. Phys. D Appl. Phys., 20, 1623,
<a href="https://doi.org/10.1088/0022-3727/20/12/013" target="_blank">https://doi.org/10.1088/0022-3727/20/12/013</a>, 1987.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Mett and Hyde(2004)</label><mixed-citation>
      
Mett, R. R. and Hyde, J. S.: Microwave leakage from field modulation slots in
TE011 electron paramagnetic resonance cavities, Rev. Sci.
Instrum., 76, 014702, <a href="https://doi.org/10.1063/1.1823748" target="_blank">https://doi.org/10.1063/1.1823748</a>, 2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Mett et al.(2009)</label><mixed-citation>
      
Mett, R. R., Sidabras, J. W., and Hyde, J. S.: Coupling of waveguide and
resonator by inductive and capacitive irises for EPR spectroscopy, Appl.
Magn. Reson., 35, 285–318, <a href="https://doi.org/10.1007/s00723-008-0162-0" target="_blank">https://doi.org/10.1007/s00723-008-0162-0</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Misra(2011)</label><mixed-citation>
      
Misra, M.: Multifrequency Electron Paramagnetic Resonance: Theory and
Applications, Wiley, ISBN 9783527633531, <a href="https://doi.org/10.1002/9783527633531" target="_blank">https://doi.org/10.1002/9783527633531</a>, 2011.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>NejatyJahromy et al.(2021)</label><mixed-citation>
      
NejatyJahromy, Y., Roy, S. C., Glaum, R., and Schiemann, O.: Multi-Frequency
and Single-Crystal EPR on V4+ in W-Doped <i>β</i>-Vanadyl(V) Phosphate: Hyperfine
Coupling- and <i>g</i>-Tensor Values and Orientation, Appl. Magn. Reson., 52,
169–175, <a href="https://doi.org/10.1007/s00723-020-01303-0" target="_blank">https://doi.org/10.1007/s00723-020-01303-0</a>, 2021.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Nesmelov et al.(2004)</label><mixed-citation>
      
Nesmelov, Y. E., Gopinath, A., and Thomas, D. D.: Aqueous sample in an EPR
cavity: sensitivity considerations, J. Magn. Reson., 167,
138–146, <a href="https://doi.org/10.1016/j.jmr.2003.12.005" target="_blank">https://doi.org/10.1016/j.jmr.2003.12.005</a>, 2004.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Polyhach et al.(2012)</label><mixed-citation>
      
Polyhach, Y., Bordignon, E., Tschaggelar, R., Gandra, S., Godt, A., and
Jeschke, G.: High sensitivity and versatility of the DEER experiment on
nitroxide radical pairs at Q-band frequencies, Phys. Chem. Chem. Phys., 14,
10762, <a href="https://doi.org/10.1039/c2cp41520h" target="_blank">https://doi.org/10.1039/c2cp41520h</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Raitsimring et al.(2012)</label><mixed-citation>
      
Raitsimring, A., Astashkin, A., Enemark, J. H., Blank, A., Twig, Y., Song, Y.,
and Meade, T. J.: Dielectric Resonator for K<sub><i>a</i></sub>-Band Pulsed EPR Measurements
at Cryogenic Temperatures: Probehead Construction and Applications, Appl.
Magn. Reson., 42, 441–452, <a href="https://doi.org/10.1007/s00723-012-0313-1" target="_blank">https://doi.org/10.1007/s00723-012-0313-1</a>, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Reijerse and Savitsky(2017)</label><mixed-citation>
      
Reijerse, E. and Savitsky, A.: Electron Paramagnetic Resonance Instrumentation, eMagRes, 6, 187–206,
<a href="https://doi.org/10.1002/9780470034590.emrstm1511" target="_blank">https://doi.org/10.1002/9780470034590.emrstm1511</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Reijerse et al.(2012)</label><mixed-citation>
      
Reijerse, E., Lendzian, F., Isaacson, R., and Lubitz, W.: A tunable general
purpose Q-band resonator for CW and pulse EPR/ENDOR experiments with large
sample access and optical excitation, J. Magn. Reson., 214, 237–243,
<a href="https://doi.org/10.1016/j.jmr.2011.11.011" target="_blank">https://doi.org/10.1016/j.jmr.2011.11.011</a>, 2012.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Roessler and Salvadori(2018)</label><mixed-citation>
      
Roessler, M. M. and Salvadori, E.: Principles and applications of EPR
spectroscopy in the chemical sciences, Chem. Soc. Rev., 47, 2534–2553,
<a href="https://doi.org/10.1039/c6cs00565a" target="_blank">https://doi.org/10.1039/c6cs00565a</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Savitsky et al.(2013)</label><mixed-citation>
      
Savitsky, A., Grishin, Y., Rakhmatullin, R., Reijerse, E., and Lubitz, W.: An
improved coupling design for high-frequency TE011 electron paramagnetic
resonance cavities, Rev. Sci. Instrum., 84, 014704, <a href="https://doi.org/10.1063/1.4788735" target="_blank">https://doi.org/10.1063/1.4788735</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Schweiger and Jeschke(2001)</label><mixed-citation>
      
Schweiger, A. and Jeschke, G.: Principles of Pulse Electron Paramagnetic
Resonance, Oxford University Press, ISBN 9780198506348,
<a href="https://doi.org/10.1093/oso/9780198506348.001.0001" target="_blank">https://doi.org/10.1093/oso/9780198506348.001.0001</a>, 2001.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Sidabras et al.(2017)</label><mixed-citation>
      
Sidabras, J. W., Richie, J. E., and Hyde, J. S.: Axially uniform magnetic
field-modulation excitation for electron paramagnetic resonance in
rectangular and cylindrical cavities by slot cutting, J. Magn.
Reson., 274, 115–124, <a href="https://doi.org/10.1016/j.jmr.2016.11.014" target="_blank">https://doi.org/10.1016/j.jmr.2016.11.014</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Sienkiewicz et al.(1996)</label><mixed-citation>
      
Sienkiewicz, A., Smith, B. G., Veselov, A., and Scholes, C. P.: Tunable Q-band
resonator for low temperature electron paramagnetic resonance/electron
nuclear double resonance measurements, Rev. Sci. Instrum., 67, 2134–2138,
<a href="https://doi.org/10.1063/1.1147027" target="_blank">https://doi.org/10.1063/1.1147027</a>, 1996.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>Stoll and Schweiger(2006)</label><mixed-citation>
      
Stoll, S. and Schweiger, A.: EasySpin, a comprehensive software package for
spectral simulation and analysis in EPR, J. Magn. Reson., 178, 42–55,
<a href="https://doi.org/10.1016/j.jmr.2005.08.013" target="_blank">https://doi.org/10.1016/j.jmr.2005.08.013</a>, 2006.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>Tschaggelar et al.(2009)</label><mixed-citation>
      
Tschaggelar, R., Kasumaj, B., Santangelo, M. G., Forrer, J., Leger, P., Dube,
H., Diederich, F., Harmer, J., Schuhmann, R., García-Rubio, I., and Jeschke,
G.: Cryogenic 35GHz pulse ENDOR probehead accommodating large sample sizes:
Performance and applications, J. Magn. Reson., 200, 81–87,
<a href="https://doi.org/10.1016/j.jmr.2009.06.007" target="_blank">https://doi.org/10.1016/j.jmr.2009.06.007</a>, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>Tschaggelar et al.(2017)</label><mixed-citation>
      
Tschaggelar, R., Breitgoff, F. D., Oberhänsli, O., Qi, M., Godt, A., and
Jeschke, G.: High-Bandwidth Q-Band EPR Resonators, Appl. Magn. Reson., 48,
1273–1300, <a href="https://doi.org/10.1007/s00723-017-0956-z" target="_blank">https://doi.org/10.1007/s00723-017-0956-z</a>, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>Weidinger et al.(1998)</label><mixed-citation>
      
Weidinger, A., Waiblinger, M., Pietzak, B., and Almeida Murphy, T.: Atomic
nitrogen in C60:N@C60, Appl. Phys. A-Mater., 66, 287–292,
<a href="https://doi.org/10.1007/s003390050668" target="_blank">https://doi.org/10.1007/s003390050668</a>, 1998.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>Wittmann et al.(2018)</label><mixed-citation>
      
Wittmann, J., Can, T., Eckardt, M., Harneit, W., Griffin, R., and Corzilius,
B.: High-precision measurement of the electron spin <i>g</i> factor of trapped
atomic nitrogen in the endohedral fullerene N@C60, J. Magn. Reson., 290,
12–17, <a href="https://doi.org/10.1016/j.jmr.2018.02.019" target="_blank">https://doi.org/10.1016/j.jmr.2018.02.019</a>, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>Zhang et al.(2010)</label><mixed-citation>
      
Zhang, Z., Fleissner, M. R., Tipikin, D. S., Liang, Z., Moscicki, J. K., Earle,
K. A., Hubbell, W. L., and Freed, J. H.: Multifrequency Electron Spin
Resonance Study of the Dynamics of Spin Labeled T4 Lysozyme, J. Phys. Chem.
B, 114, 5503–5521, <a href="https://doi.org/10.1021/jp910606h" target="_blank">https://doi.org/10.1021/jp910606h</a>, 2010.

    </mixed-citation></ref-html>--></article>
