<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing with OASIS Tables v3.0 20080202//EN" "https://jats.nlm.nih.gov/nlm-dtd/publishing/3.0/journalpub-oasis3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:oasis="http://docs.oasis-open.org/ns/oasis-exchange/table" xml:lang="en" dtd-version="3.0" article-type="research-article">
  <front>
    <journal-meta><journal-id journal-id-type="publisher">MR</journal-id><journal-title-group>
    <journal-title>Magnetic Resonance</journal-title>
    <abbrev-journal-title abbrev-type="publisher">MR</abbrev-journal-title><abbrev-journal-title abbrev-type="nlm-ta">Magn. Reson.</abbrev-journal-title>
  </journal-title-group><issn pub-type="epub">2699-0016</issn><publisher>
    <publisher-name>Copernicus Publications</publisher-name>
    <publisher-loc>Göttingen, Germany</publisher-loc>
  </publisher></journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.5194/mr-7-99-2026</article-id><title-group><article-title>Segmented-overlap Fourier filtering and averaging (SOFFA) approach to improve concentration sensitivity of magnetic resonance spectra</article-title><alt-title>SOFFA filtering for magnetic resonance</alt-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes" rid="aff1">
          <name><surname>Sidabras</surname><given-names>Jason W.</given-names></name>
          <email>jwsidabras@mcw.edu</email>
        <ext-link>https://orcid.org/0000-0002-4537-7501</ext-link></contrib>
        <aff id="aff1"><label>1</label><institution>Medical College of Wisconsin, Department of Biophysics, 8701 Watertown Plank Rd, Wauwatosa, WI 53226, USA</institution>
        </aff>
      </contrib-group>
      <author-notes><corresp id="corr1">Jason W. Sidabras (jwsidabras@mcw.edu)</corresp></author-notes><pub-date><day>2</day><month>July</month><year>2026</year></pub-date>
      
      <volume>7</volume>
      <issue>2</issue>
      <fpage>99</fpage><lpage>112</lpage>
      <history>
        <date date-type="received"><day>27</day><month>February</month><year>2026</year></date>
           <date date-type="rev-request"><day>6</day><month>March</month><year>2026</year></date>
           <date date-type="rev-recd"><day>18</day><month>May</month><year>2026</year></date>
           <date date-type="accepted"><day>26</day><month>May</month><year>2026</year></date>
      </history>
      <permissions>
        <copyright-statement>Copyright: © 2026 Jason W. Sidabras</copyright-statement>
        <copyright-year>2026</copyright-year>
      <license license-type="open-access"><license-p>This work is licensed under the Creative Commons Attribution 4.0 International License. To view a copy of this licence, visit <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link></license-p></license></permissions><self-uri xlink:href="https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026.html">This article is available from https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026.html</self-uri><self-uri xlink:href="https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026.pdf">The full text article is available as a PDF file from https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026.pdf</self-uri>
      <abstract><title>Abstract</title>

      <p id="d2e77">The segmented-overlap Fourier filtering and averaging (SOFFA) data acquisition method is described in detail for magnetic resonance spectroscopy. In this work, the four processes that encompass the SOFFA data acquisition method are detailed: (i) oversampling spectral segments, (ii) Fourier block-filtering, (iii) segment-overlap averaging, and (iv) decimation. Three experimental examples are shown: first, conventional continuous-wave (CW) electron paramagnetic resonance (EPR) is compared to SOFFA-CW of a single reduced <inline-formula><mml:math id="M1" display="inline"><mml:mrow class="chem"><mml:mo>[</mml:mo><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">Fe</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">S</mml:mi><mml:msup><mml:mo>]</mml:mo><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M2" display="inline"><mml:mrow><mml:mi mathvariant="normal">S</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) at concentrations of 1 mM, 100 <inline-formula><mml:math id="M3" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula>, and 10 <inline-formula><mml:math id="M4" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula>, showing an average increase in concentration sensitivity by a factor of 5.6 in a 100 min measurement time. Second, an experimental comparison of CW and SOFFA non-adiabatic rapid-scan (SOFFA-NARS) data with similar filter parameters and field modulation amplitude demonstrates a factor of 10.3 in signal-to-noise (SNR) improvement (32 min measurement time) for a 150 <inline-formula><mml:math id="M5" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> site-directed spin-labeled hemoglobin in 82 % glycerol at 18 <inline-formula><mml:math id="M6" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">°</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>. Finally, an SNR-matched experiment of free TEMPO at 10 <inline-formula><mml:math id="M7" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> concentration is presented, where CW was performed at 400 scans (273 min) compared to SOFFA-CW with an overlap factor of 100 (20 min). Also shown is the effect of <inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise on these CW and SOFFA-CW experiments. Ultimately, the SOFFA algorithm achieves sensitivity enhancement by combining massive digital oversampling and out-of-band noise filtration with coherent spatial accumulation of highly overlapped spectral segments. The gains reported here are phenomenological and are grounded in established digital signal processing principles but are validated through experiments rather than closed-form analytical prediction. This fundamental restructuring of the acquisition chain successfully decouples high-frequency filtering from low-frequency averaging while providing a data collection scheme that suppresses <inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise. The SOFFA method can be implemented to perform real-time segmented processing and, combined with more sophisticated averaging methods, will push the state-of-the-art sensitivity in magnetic resonance spectroscopy.</p>
  </abstract>
    
<funding-group>
<award-group id="gs1">
<funding-source>Horizon 2020</funding-source>
<award-id>745702</award-id>
</award-group>
<award-group id="gs2">
<funding-source>National Institutes of Health</funding-source>
<award-id>R01GM149568</award-id>
</award-group>
<award-group id="gs3">
<funding-source>National Institutes of Health</funding-source>
<award-id>U01AI189427</award-id>
</award-group>
</funding-group>
</article-meta>
  </front>
<body>
      

<sec id="Ch1.S1" sec-type="intro">
  <label>1</label><title>Introduction</title>
      <p id="d2e203">In this work, the segmented-overlap Fourier filtering and averaging (SOFFA) method for magnetic resonance data acquisition and filtering is established. In a typical continuous-wave (CW) electron paramagnetic resonance (EPR) experiment, a spectrum is collected as a continuous signal; i.e., the spectroscopist must “play” it until the end and, only then, repeat for averaging. However, the signal is typically time invariant and therefore can be collected in a number of unique ways. It is shown herein that, by collecting a magnetic resonance spectrum in segments, an additional parameter related to the overlap of each scan is introduced while increasing the available number of data points collected beyond hardware limitations. Each acquired segment contains a field- or frequency-stepped correlated signal and uncorrelated noise. For processing, each segment is oversampled, filtered block-wise, concatenated, and decimated to a standard number of points (i.e., 1024), resulting in a signal-to-noise (SNR) improvement compared to traditional CW or non-adiabatic rapid-scan (NARS) data collection, averaging, and filtering methods for the same measurement time. The SOFFA data acquisition method can be adopted for experiments with a swept parameter, correlated signal, and uncorrelated noise. Here, this is demonstrated for conventional CW and NARS techniques. A visualization of the scheme is illustrated in Fig. <xref ref-type="fig" rid="F1"/>.</p>

      <fig id="F1"><label>Figure 1</label><caption><p id="d2e210">A visualization of the SOFFA method. A Gaussian absorption spectrum is simulated with a half width of 1 <inline-formula><mml:math id="M10" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> and an amplitude of unity. Shown here is a representation of the simulated experiment. <bold>(A)</bold> Random (white) noise is added. <bold>(B)</bold> A small set of unfiltered segmented data is plotted, showing field steps <inline-formula><mml:math id="M11" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> with oversampling. <bold>(C)</bold> When a Gaussian convolution filter of Eq. (<xref ref-type="disp-formula" rid="Ch1.E6"/>) is applied to <bold>(A)</bold>, the expected improvement in SNR is shown, similarly to increasing the time constant. <bold>(D)</bold> However, using the SOFFA method, <inline-formula><mml:math id="M12" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> is increased as a function of <inline-formula><mml:math id="M13" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>, where <inline-formula><mml:math id="M14" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> is in points. The discrete shift between adjacent segments, of sweep size <inline-formula><mml:math id="M15" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> in mT, leads to further SNR improvement being exhibited due to the increased averaging during concatenation of filtered data.</p></caption>
        <graphic xlink:href="https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026-f01.png"/>

      </fig>

      <p id="d2e281">Illustrated in Fig. <xref ref-type="fig" rid="F1"/>A, is a representative typical CW-EPR spectrum of a Gaussian signal with white noise. After standard filtering, the SNR ratio is improved, as shown in Fig. <xref ref-type="fig" rid="F1"/>C. For SOFFA, the spectrometer acquires a spectrum by stepping a narrow sweep window <inline-formula><mml:math id="M16" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> across the full field range in overlapping segments and then maps each segment onto a common high-resolution grid via overlap-add accumulation, shown in Fig. <xref ref-type="fig" rid="F1"/>B. Each segment is individually filtered in the frequency domain before being re-accumulated and averaged across the overlapping regions. The resulting high-resolution grid is then smoothed and decimated to the desired output point count, yielding a final spectrum with substantially improved SNR compared to a single full-width sweep. Improvement of the SNR depends on the step size <inline-formula><mml:math id="M17" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>, which increases the averages due to overlapping <inline-formula><mml:math id="M18" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>. The overlap between segments is the key feature: it provides redundant sampling at every field position, and so the averaging step coherently reinforces the signal while averaging down incoherent noise.</p>
      <p id="d2e313">The improved SNR ratio achieved by the SOFFA method can be leveraged to reduce the time required for an experiment, thereby increasing throughput. In traditional EPR experiments, SNR improves as <inline-formula><mml:math id="M19" display="inline"><mml:msqrt><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:msqrt></mml:math></inline-formula> with the number of averages <inline-formula><mml:math id="M20" display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, meaning that doubling the SNR requires quadrupling the experiment time. With the SOFFA method, the same SNR level can, in principle, be achieved in a fraction of that time by exploiting the overlap averaging <inline-formula><mml:math id="M21" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> and segment filtering rather than brute-force averaging. However, a practical minimum experiment time exists for SOFFA-CW that is not present in conventional averaging.</p>
      <p id="d2e346">The limitations of SOFFA are that the per-segment sweep rate must remain slow enough to avoid passage <xref ref-type="bibr" rid="bib1.bibx35" id="paren.1"/>, and the magnet step size is bounded by the field controller precision and hysteresis of the electromagnet, with practical step sizes on commercial instruments being limited to 0.01 <inline-formula><mml:math id="M22" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>. Together, these constraints set a floor on the total acquisition time and a ceiling on the number of averages due to overlapping <inline-formula><mml:math id="M23" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>, which cannot be increased without violating one of the hardware limits. Within those bounds, SOFFA decouples the SNR-per-unit-time relationship of conventional averaging. These two practical hardware limitations (minimum step size and maximum sweep rate) are largely eliminated using the non-adiabatic rapid scan (NARS) method <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx15 bib1.bibx13 bib1.bibx8 bib1.bibx38" id="paren.2"/>.</p>
      <p id="d2e370">In a NARS experiment, the field or frequency is swept at a rate and amplitude that allows the spin system to return to thermal equilibrium, and the pure-absorption lineshape is recorded. In this sense, NARS mimics a CW EPR experiment, and the power saturation profile of the sample remains unperturbed. Typically, NARS experiments employ a low amplitude (1 <inline-formula><mml:math id="M24" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>) and rate (below 50 kHz) for field or frequency sweeps. The increased rate and amplitude at a fixed field position of a NARS experiment generate harmonics which are captured completely with a digitizer. In practice, the spectrum is collected in segments by stepping the static field to obtain the full spectrum. Each step is windowed, zero-filled, concatenated, and filtered. The advantage of NARS comes from the modern data collection methods (averaging, digital filtering, etc.), collection of pure-absorption spectra, and SNR improvements due to overlapping segments during concatenation. The NARS method collects quadrature pure-absorption EPR spectra, which can be pseudo-modulated to the conventional first-derivative EPR spectrum <xref ref-type="bibr" rid="bib1.bibx6 bib1.bibx8" id="paren.3"/>. NARS has been used by Hyde and colleagues <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx13" id="paren.4"/> at L-band (1.2 GHz) to extend the deconvolution method of CW EPR distance determination from 18–25 to 30–35 <inline-formula><mml:math id="M25" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">Å</mml:mi></mml:mrow></mml:math></inline-formula> <xref ref-type="bibr" rid="bib1.bibx15" id="paren.5"/> and has been used to increase the resolution for a copper imidazole complex <xref ref-type="bibr" rid="bib1.bibx8" id="paren.6"/>. Additionally, NARS was independently shown by Eaton and colleagues in applications of spectra as wide as 620 <inline-formula><mml:math id="M26" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> using concatenation without overlap <xref ref-type="bibr" rid="bib1.bibx38" id="paren.7"/>.</p>
      <p id="d2e413">It has been established that NARS data collection produces a comb filter that suppresses high-frequency noise <xref ref-type="bibr" rid="bib1.bibx37 bib1.bibx4" id="paren.8"/>. However, these methods are susceptible to low-frequency noise that is correlated with the field sweep or the transfer function of the frequency response of the system. Filtering such noise is problematic since the features may contain the same frequency content as the absorption spectrum. Pseudo-modulation using the moving-difference (MDIFF) algorithm to calculate the conventional first-harmonic derivative-like spectrum further reduces some low-frequency noise <xref ref-type="bibr" rid="bib1.bibx8" id="paren.9"/>. However, the challenge of properly filtering NARS data still remains. The SOFFA data acquisition method is shown to remove challenging noise profiles, and the method is well suited for magnetic resonance spectroscopy with minimum changes to data acquisition.</p>
      <p id="d2e422">It should be noted that the SNR improvements reported herein are phenomenological in character. While the SOFFA method is constructed from well-established DSP principles (oversampling theory, Fourier block-filtering, overlap-add averaging, and decimation), a complete closed-form analytical expression that quantitatively predicts the net gain from the combination of all four processing stages is beyond the scope of this work. The experimental results serve as the primary validation. Future work will focus on a rigorous theoretical framework that decomposes the contributing factors and yields quantitative predictions as a function of acquisition parameters.</p>
      <p id="d2e425">In this work, the SOFFA data acquisition method is tested with (i) an experimental comparison between an averaged and filtered CW spectrum and a SOFFA-CW spectrum using concentrations of 1 mM, 100 <inline-formula><mml:math id="M27" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula>, and 10 <inline-formula><mml:math id="M28" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> of apo [FeFe]-hydrogenase (single reduced <inline-formula><mml:math id="M29" display="inline"><mml:mrow class="chem"><mml:mo>[</mml:mo><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">Fe</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">S</mml:mi><mml:msup><mml:mo>]</mml:mo><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>; <inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:mi mathvariant="normal">S</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>; <xref ref-type="bibr" rid="bib1.bibx16" id="paren.10"/>); (ii) an experimental comparison of a SOFFA-NARS spectrum of 150 <inline-formula><mml:math id="M31" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> site-directed spin-labeled hemoglobin protein in 82 % glycerol at 18 <inline-formula><mml:math id="M32" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">°</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> to averaged and filtered CW spectrum; and (iii) an experimental comparison between CW and SOFFA-CW using a 10 <inline-formula><mml:math id="M33" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> TEMPO (2,2,6,6-tetramethylpiperidine-1-oxyl) radical in water where SNR is matched.</p>
</sec>
<sec id="Ch1.S2">
  <label>2</label><title>Methods</title>
<sec id="Ch1.S2.SS1">
  <label>2.1</label><title>Continuous-wave EPR</title>
      <p id="d2e536">Three concentrations of apo [FeFe]-hydrogenase from <italic>Chlamydomonas reinhardtii</italic> (single reduced <inline-formula><mml:math id="M34" display="inline"><mml:mrow class="chem"><mml:mo>[</mml:mo><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">Fe</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">S</mml:mi><mml:msup><mml:mo>]</mml:mo><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:mi mathvariant="normal">S</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>) were prepared at 1 mM, 100 <inline-formula><mml:math id="M36" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula>, and 10 <inline-formula><mml:math id="M37" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> and confirmed by UV-VIS absorption at 400 <inline-formula><mml:math id="M38" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">nm</mml:mi></mml:mrow></mml:math></inline-formula> <xref ref-type="bibr" rid="bib1.bibx16" id="paren.11"/>. All spectra were collected at 15 K with an incident microwave power of 0.63 <inline-formula><mml:math id="M39" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula> and a field modulation amplitude of 0.5 <inline-formula><mml:math id="M40" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> at 100 kHz. The 1 mM reference spectrum was collected as a 4 min scan over 100 <inline-formula><mml:math id="M41" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> with 4096 points averaged 9 times. The 100 <inline-formula><mml:math id="M42" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> and 10 <inline-formula><mml:math id="M43" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> concentrations were each collected with 25 averages (4 min scan, 100 <inline-formula><mml:math id="M44" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>, 4096 points) for a total measurement time of 100 min.</p>
      <p id="d2e666">For the SOFFA-CW experiments, the center field was stepped in 0.5 <inline-formula><mml:math id="M45" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> increments over a total sweep of 100 <inline-formula><mml:math id="M46" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>, yielding <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:mi>K</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">200</mml:mn></mml:mrow></mml:math></inline-formula> steps, with a segment sweep width <inline-formula><mml:math id="M48" display="inline"><mml:mrow><mml:mi>g</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">25</mml:mn><mml:mspace width="0.125em" linebreak="nobreak"/><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> and 4096 points per segment. Each segment was collected over 30 s for a total measurement time of 100 min. Segments were acquired using a ProDEL script in Bruker Xepr (v.2.6b-160), which steps the center field and stores each segment in Bruker DSC/DTA format.<fn id="Ch1.Footn1"><p id="d2e713">The ProDEL script and Python GUI used to collect and process SOFFA data are available at <uri>https://github.com/jsidabras/SOFFABruker</uri> (last access: 18 June 2026).</p></fn> The ProDEL script iterates discrete static field steps, triggers acquisition at each position, and saves the resulting 2D dataset. Software overhead is negligible; the acquisition rate is limited by the hardware field-settling time of the magnet between steps. This approach has been validated for field sweeps up to 8192 points with 1200 steps (0.01 <inline-formula><mml:math id="M49" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> step size over 12 <inline-formula><mml:math id="M50" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>).</p>
      <p id="d2e737">The single reduced <inline-formula><mml:math id="M51" display="inline"><mml:mrow class="chem"><mml:mo>[</mml:mo><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">Fe</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">S</mml:mi><mml:msup><mml:mo>]</mml:mo><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> CW EPR spectra and complementary SOFFA-CW EPR spectra were collected on a Bruker E580 Elexsys X-band spectrometer (9.70 GHz) equipped with a bismuth germanate (<inline-formula><mml:math id="M52" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">Bi</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">GeO</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, BGO) dielectric resonator retrofitted in a Bruker MD5 housing <xref ref-type="bibr" rid="bib1.bibx11" id="paren.12"/>.</p>
      <p id="d2e789">The 10 <inline-formula><mml:math id="M53" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> TEMPO spectra were recorded on a Bruker E500 Elexsys II X-band spectrometer equipped with a Super High-Q cylindrical <inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:msub><mml:mtext>TE</mml:mtext><mml:mn mathvariant="normal">011</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula> model (no. E4122011). The traditional CW EPR was measured with a 10 <inline-formula><mml:math id="M55" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> sweep of 1024 points over 41.94 s with 400 averages, 20.48 ms time constant at 3.2 <inline-formula><mml:math id="M56" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula>, and 0.1 <inline-formula><mml:math id="M57" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> field modulation at 100 kHz. SOFFA-CW was performed with a 3 <inline-formula><mml:math id="M58" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> sweep of 8192 points over 10.39 s, with 100 steps of 0.1 <inline-formula><mml:math id="M59" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> each, a 1.28 ms time constant at 3.2 <inline-formula><mml:math id="M60" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula>, and 0.1 <inline-formula><mml:math id="M61" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> field modulation at 100 kHz.</p>
</sec>
<sec id="Ch1.S2.SS2">
  <label>2.2</label><title>Non-adiabatic rapid scan</title>
      <p id="d2e878">The conventional CW comparison and NARS spectra were collected on a custom-built X-band bridge dedicated to segmented-NARS spectroscopy <xref ref-type="bibr" rid="bib1.bibx9" id="paren.13"/>. A 150 <inline-formula><mml:math id="M62" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> site-directed spin-labeled hemoglobin sample in 82 % glycerol was measured at 18 <inline-formula><mml:math id="M63" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">°</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> in a five-loop–four-gap loop–gap resonator at 9.81 GHz. For the conventional CW reference, 16 averages of 2 min scans were collected over 20 <inline-formula><mml:math id="M64" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> with 0.1 <inline-formula><mml:math id="M65" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> field modulation at 100 kHz, a 5 ms time constant, and 1 <inline-formula><mml:math id="M66" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula> of incident microwave power. The 5 ms time constant was chosen to minimize lock-in pre-filtering within each scan, preserving the full signal bandwidth for subsequent filtering post-processing. For the SOFFA-NARS experiment, the static field was stepped in 0.025 <inline-formula><mml:math id="M67" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> increments with an overlap of <inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">40</mml:mn></mml:mrow></mml:math></inline-formula> using a trapezoidal field ramp at 11.33 kHz with a 50 <inline-formula><mml:math id="M69" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula> flat region and an amplitude of 0.5 <inline-formula><mml:math id="M70" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>. Data were acquired over 95 % of the trapezoidal sweep in one direction; the resulting edge effects appear as periodic noise outside the signal power spectral density and are suppressed by segment-overlap averaging. Both experiments required approximately 32 min of measurement time.</p>
</sec>
<sec id="Ch1.S2.SS3">
  <label>2.3</label><title>SNR definition</title>
      <p id="d2e975">The SNR is defined as

            <disp-formula id="Ch1.E1" content-type="numbered"><label>1</label><mml:math id="M71" display="block"><mml:mrow><mml:mtext>SNR</mml:mtext><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mtext>pk</mml:mtext></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>noise</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          where <inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mtext>pk</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the peak-to-peak signal amplitude, and <inline-formula><mml:math id="M73" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>noise</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the standard deviation of the noise, computed from an off-resonance region of the spectrum <xref ref-type="bibr" rid="bib1.bibx26 bib1.bibx23" id="paren.14"/>.</p>
</sec>
</sec>
<sec id="Ch1.S3">
  <label>3</label><title>Theory and implementation</title>
      <p id="d2e1038">The SOFFA data acquisition method consists of four distinct processing stages: (i) oversampling spectral segments, (ii) Fourier block-filtering, (iii) segment-overlap averaging, and (iv) decimation. The nomenclature of the Welch fast Fourier transform (FFT) procedure for power spectral density estimation <xref ref-type="bibr" rid="bib1.bibx36" id="paren.15"/> is adopted throughout due to the similarity of spectral segmentation to that procedure. Table <xref ref-type="table" rid="T1"/> defines all symbols used in this work, with a graphic representation in Fig. <xref ref-type="fig" rid="F2"/>.</p>

      <fig id="F2"><label>Figure 2</label><caption><p id="d2e1050">Illustration of spectral segmentation with parameters and variables.</p></caption>
        <graphic xlink:href="https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026-f02.png"/>

      </fig>

<table-wrap id="T1" specific-use="star"><label>Table 1</label><caption><p id="d2e1062">Principal variables and symbols used in this work.</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Symbol</oasis:entry>
         <oasis:entry colname="col2">Definition</oasis:entry>
         <oasis:entry colname="col3">Units</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry namest="col1" nameend="col3">Signal representation </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M74" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Continuous noisy spectrum in the swept domain</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:mover accent="true"><mml:mi>x</mml:mi><mml:mo mathvariant="normal" stretchy="false">̃</mml:mo></mml:mover><mml:mo>[</mml:mo><mml:mi>i</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Discretized full-spectrum signal on the conventional grid</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">True signal component</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"><inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Additive noise component (white or <inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry namest="col1" nameend="col3">Acquisition and segmentation </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M79" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Total spectral sweep width</oasis:entry>
         <oasis:entry colname="col3">mT</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M80" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Segment sweep width</oasis:entry>
         <oasis:entry colname="col3">mT</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M81" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Field step size between adjacent segment starts</oasis:entry>
         <oasis:entry colname="col3">mT</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M82" display="inline"><mml:mi>K</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Total number of acquired segments (or segment positions)</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M83" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Number of points in a conventional full-spectrum acquisition</oasis:entry>
         <oasis:entry colname="col3">pts</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M84" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Number of points retained in each segment window</oasis:entry>
         <oasis:entry colname="col3">pts</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M85" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Discrete shift between adjacent segment starts on the fine grid</oasis:entry>
         <oasis:entry colname="col3">pts</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M86" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Segment index, <inline-formula><mml:math id="M87" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mo>,</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>,</mml:mo><mml:mi>K</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:msub><mml:mi>x</mml:mi><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi>j</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M89" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula>th acquired segment, <inline-formula><mml:math id="M90" display="inline"><mml:mrow><mml:mi>j</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mo>,</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>,</mml:mo><mml:mi>L</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M91" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Overlap factor between neighboring segments</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">e</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Total experiment time</oasis:entry>
         <oasis:entry colname="col3">s</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M93" display="inline"><mml:mi mathvariant="italic">τ</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Acquisition time per collected trace</oasis:entry>
         <oasis:entry colname="col3">s</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"><inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Number of conventional averages</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry namest="col1" nameend="col3">Fourier filtering and accumulation </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M95" display="inline"><mml:mi mathvariant="italic">ω</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Discrete frequency index in Fourier space</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M96" display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Center point of the Gaussian filter in Fourier space</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>n</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Gaussian filter variance</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:msub><mml:mtext>H</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Gaussian filter applied to segment <inline-formula><mml:math id="M99" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M100" display="inline"><mml:mrow><mml:msub><mml:mtext>Y</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Fourier transform of the zero-filled, field-aligned <inline-formula><mml:math id="M101" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula>th segment</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:msub><mml:mtext>G</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Filtered Fourier-domain segment</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"><inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:msub><mml:mi>y</mml:mi><mml:mtext>tot</mml:mtext></mml:msub><mml:mo>[</mml:mo><mml:mi>i</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">High-resolution concatenated spectrum before final decimation</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry namest="col1" nameend="col3">Final output and SNR quantities </oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M104" display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Number of points in the final decimated SOFFA spectrum</oasis:entry>
         <oasis:entry colname="col3">pts</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:mi>y</mml:mi><mml:mo>[</mml:mo><mml:mi>p</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Final decimated SOFFA spectrum, <inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:mi>p</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mo>,</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>,</mml:mo><mml:mi>P</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mtext>pk</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Peak-to-peak signal amplitude</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mtext>noise</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Standard deviation of the off-resonance noise</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">OSR</oasis:entry>
         <oasis:entry colname="col2">Oversampling ratio</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Effective sampling frequency</oasis:entry>
         <oasis:entry colname="col3">Hz</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M110" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mtext>cw</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Spectral bandwidth of the conventional CW experiment</oasis:entry>
         <oasis:entry colname="col3">Hz</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mi>c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Effective time constant of the oversampled acquisition</oasis:entry>
         <oasis:entry colname="col3">s</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"><inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mtext>cw</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col2">Conventional CW time constant</oasis:entry>
         <oasis:entry colname="col3">s</oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e1919">Here, linear noise is assumed, such that,

          <disp-formula id="Ch1.E2" content-type="numbered"><label>2</label><mml:math id="M113" display="block"><mml:mrow><mml:mover accent="true"><mml:mi>x</mml:mi><mml:mo mathvariant="normal" stretchy="false">̃</mml:mo></mml:mover><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>=</mml:mo><mml:mi>S</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>+</mml:mo><mml:mi>N</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

        where <inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is the signal that is detected, and <inline-formula><mml:math id="M115" display="inline"><mml:mrow><mml:mi>N</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> is either spectrally flat (white) noise, characterized by a frequency-independent power spectral density, or <inline-formula><mml:math id="M116" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> (pink) noise, characterized by a power spectral density that increases with decreasing frequency. Noise that is a function of the signal is beyond the scope of this work.</p>
      <p id="d2e2002">For conventionally acquired data, the number of points, scan rate, and time constant are chosen to represent the spectrum completely and without spectral distortions; simulated data for visualization are shown in Fig. <xref ref-type="fig" rid="F1"/>A. For each new scan, the noise is uncorrelated; therefore, the data can be averaged and filtered. For example, filtered data of Fig. <xref ref-type="fig" rid="F1"/>A are shown in Fig. <xref ref-type="fig" rid="F1"/>C. Fourier filtering averaged data before or after summing the individual scans are equivalent. With traditional averaging and white noise, the SNR follows a strict <inline-formula><mml:math id="M117" display="inline"><mml:msqrt><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:msqrt></mml:math></inline-formula> gain, where <inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the number of averages. The same signal–time trade-off exists when increasing the number of collected data points while maintaining equivalent measurement time.</p>
      <p id="d2e2034">In the following sections, the four processes utilized to create the SOFFA data acquisition method are detailed: (i) oversampling spectral segments, (ii) Fourier block-filtering each segment separately, (iii) segment-overlap averaging, and (iv) decimation. It is the combination of these processes that improves the SNR ratio for the same amount of data collection time.</p>
<sec id="Ch1.S3.SS1">
  <label>3.1</label><title>Oversampling spectral segments</title>
      <p id="d2e2044">In the SOFFA data acquisition method, each field- and/or frequency-swept segment has the following properties: (i) the overlapping noise is non-coherent, (ii) field- or frequency-dependent features are considered to be the signal, and (iii) each segment is an oversampled section of the whole spectrum. Here, oversampled means that each SOFFA segment is acquired with substantially more points than what is required to represent the underlying spectral features at the target final resolution.</p>
      <p id="d2e2047">In the case of the SOFFA method, all segments are collected separately and can then be further windowed to the desired length to remove potential edge effects with the window size <inline-formula><mml:math id="M119" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula>. Stepping the field by <inline-formula><mml:math id="M120" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> over the spectrum yields <inline-formula><mml:math id="M121" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> individually collected segments. The step size <inline-formula><mml:math id="M122" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> is represented by the discrete shift step size <inline-formula><mml:math id="M123" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula>, illustrated in Fig. <xref ref-type="fig" rid="F2"/>. Since magnetic resonance produces a stationary and time-invariant signal, the corresponding output blocks can be zero-filled by a length of the total collection size to begin at the same absolute step size, aligning the field- or frequency-dependent features. The zero-fill parameter is then shift-stepped by <inline-formula><mml:math id="M124" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> to align field-dependent features. To maximize the overlap averaging after filtering, the windowing function is chosen to be rectangular, and no aliasing issues exist if oversampling is used. Unlike windowing in typical block-filtering, which benefits greatly from window choice <xref ref-type="bibr" rid="bib1.bibx5" id="paren.16"/>, a rectangular window will maximize the individual contribution of each segment during the concatenation process. Any higher-order frequencies generated by discontinuities are removed in the filtering process and result in proper concatenation and aliasing.</p>
      <p id="d2e2098">In the SOFFA data acquisition method, each segment is oversampled in order to reduce the noise spectral density while keeping the signal spectral density constant <xref ref-type="bibr" rid="bib1.bibx23" id="paren.17"/>. One can estimate an effective time constant,

            <disp-formula id="Ch1.E3" content-type="numbered"><label>3</label><mml:math id="M125" display="block"><mml:mrow><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mi>c</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mn mathvariant="normal">1</mml:mn><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">e</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mi>n</mml:mi><mml:mi>K</mml:mi></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          where <inline-formula><mml:math id="M126" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the effective sampling frequency, <inline-formula><mml:math id="M127" display="inline"><mml:mrow><mml:msub><mml:mi>t</mml:mi><mml:mi mathvariant="normal">e</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the total experiment scan time, <inline-formula><mml:math id="M128" display="inline"><mml:mi>n</mml:mi></mml:math></inline-formula> is the shift step size, and <inline-formula><mml:math id="M129" display="inline"><mml:mi>K</mml:mi></mml:math></inline-formula> is the total number of segments. If the noise is predominantly white and a perfect low-pass filter is used, the SNR is improved by the oversampling ratio,

            <disp-formula id="Ch1.E4" content-type="numbered"><label>4</label><mml:math id="M130" display="block"><mml:mrow><mml:mtext>OSR</mml:mtext><mml:mo>=</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:msub><mml:mi>f</mml:mi><mml:mtext>cw</mml:mtext></mml:msub></mml:mrow></mml:mfrac></mml:mstyle><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          where <inline-formula><mml:math id="M131" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mtext>cw</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> is the inverse of the time constant <inline-formula><mml:math id="M132" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mtext>cw</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula> of the conventional CW data collection.</p>
      <p id="d2e2232">SNR is improved in oversampling by reducing the spectral bandwidth by the oversampling ratio (OSR) and effectively spreading noise power spectral density by the same amount; see Fig. <xref ref-type="fig" rid="FA1"/> in the Appendix (ii and iii) <xref ref-type="bibr" rid="bib1.bibx23" id="paren.18"/>. Since segmented magnetic resonance spectra are collected, a further decrease in the spectral bandwidth is exhibited since only a fragment of the spectrum is sampled. Ultimately, the bandwidth of the noise increases, but it is the reduction in the bandwidth of the signal (due to the collection of partial spectra) that is reduced, allowing a more aggressive filter without spectral broadening.</p>
      <p id="d2e2241">A key advantage of the segmented acquisition strategy is that it allows the whole spectrum to be oversampled far beyond what the spectrometer hardware permits in a single continuous sweep. Legacy instruments such as some Bruker E500 consoles are limited to 8192 points per continuous sweep. For example, with SOFFA, collecting a spectrum with a 2 <inline-formula><mml:math id="M133" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> segment sweep width, a 0.1 <inline-formula><mml:math id="M134" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> field step size, 4096 points per segment, and 100 steps produces 204 800 effective data points across the whole spectrum. Because the magnetic resonance signal is stationary and time-invariant, the signal contribution from every segment that covers a given field position is fully correlated, meaning the same EPR line appears at the same field value in each overlapping segment. The noise, however, is independent during each acquisition and is therefore uncorrelated between segments. The result is a whole-spectrum dataset with correlated signal and uncorrelated noise, which is precisely the condition that enables effective Fourier filtering and signal averaging to improve the SNR ratio.</p>
      <p id="d2e2260">Another advantage of oversampled segmented data collection has to do with noise that is loosely correlated to the signal or noise that is colored, such as <inline-formula><mml:math id="M135" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise. In conventional CW, the time constant acts as a low-pass filter on the data, while the sweep duration acts as a high-pass filter on the noise. Repeating full-spectrum sweeps for signal averaging introduces <inline-formula><mml:math id="M136" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise that cannot be directly filtered without broadening the EPR signal. Furthermore, because this noise is time-correlated, traditional signal averaging becomes less effective, improving the SNR ratio by less than the ideal <inline-formula><mml:math id="M137" display="inline"><mml:msqrt><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi mathvariant="normal">a</mml:mi></mml:msub></mml:mrow></mml:msqrt></mml:math></inline-formula> factor. However, by reducing the sweep into segments and maintaining the sweep rate (e.g., 60 s for 10 <inline-formula><mml:math id="M138" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> and 12 s for 2 <inline-formula><mml:math id="M139" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>; 0.167 <inline-formula><mml:math id="M140" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>), the shorter observation window inherently rejects ultra-low-frequency drift. Furthermore, due to the segment step timing and excessive overlap, any remaining correlated noise is randomized between segments. This decorrelation allows the signal averaging to approach the theoretical white-noise limit of <inline-formula><mml:math id="M141" display="inline"><mml:msqrt><mml:mi>m</mml:mi></mml:msqrt></mml:math></inline-formula>.</p>
      <p id="d2e2341">Once each of the segments is sufficiently oversampled, filtering can be employed to reduce the high-frequency content outside the spectral bandwidth by applying finite-impulse response (FIR) block-filtering techniques.</p>
</sec>
<sec id="Ch1.S3.SS2">
  <label>3.2</label><title>Fourier block-filtering each segment separately</title>
      <p id="d2e2352">The SOFFA data acquisition method differs from typical Fourier block-filtering based on two important factors: (i) each segment is a new collection of data with field- or frequency-stepped correlated signal and uncorrelated noise, and (ii) each segment overlaps the next segments for a total of <inline-formula><mml:math id="M142" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> overlapping segments; see Fig. <xref ref-type="fig" rid="F1"/>. Due to oversampling, the spectral bandwidth of the spectrum in each segment is reduced; see Fig. <xref ref-type="fig" rid="FA1"/>, comparing spectra ii and iii.</p>
      <p id="d2e2366">Fourier block-filtering is illustrated in Fig. <xref ref-type="fig" rid="F3"/>. Each segment is convolved with the filter <inline-formula><mml:math id="M143" display="inline"><mml:mrow><mml:mtext>H</mml:mtext><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula>, such that

            <disp-formula id="Ch1.E5" content-type="numbered"><label>5</label><mml:math id="M144" display="block"><mml:mrow><mml:msub><mml:mtext>G</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo><mml:mo>=</mml:mo><mml:msub><mml:mtext>Y</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo><mml:msub><mml:mtext>H</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          where <inline-formula><mml:math id="M145" display="inline"><mml:mrow><mml:msub><mml:mtext>Y</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> is the Fourier transform (Fourier space <inline-formula><mml:math id="M146" display="inline"><mml:mi mathvariant="italic">ω</mml:mi></mml:math></inline-formula>) of the discrete signal, and the convolution is <inline-formula><mml:math id="M147" display="inline"><mml:mrow><mml:msub><mml:mtext>G</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula>. In this work, a fixed FIR Gaussian filter is used, defined by

            <disp-formula id="Ch1.E6" content-type="numbered"><label>6</label><mml:math id="M148" display="block"><mml:mrow><mml:msub><mml:mtext>H</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo><mml:mo>=</mml:mo><mml:mi>exp⁡</mml:mi><mml:mfenced open="(" close=")"><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mrow><mml:mo>-</mml:mo><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>-</mml:mo><mml:mi mathvariant="italic">γ</mml:mi><mml:msup><mml:mo>)</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mn mathvariant="normal">2</mml:mn><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>n</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:mfrac></mml:mstyle></mml:mfenced><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

          where <inline-formula><mml:math id="M149" display="inline"><mml:mi mathvariant="italic">ω</mml:mi></mml:math></inline-formula> is the discretized frequency, and <inline-formula><mml:math id="M150" display="inline"><mml:mi mathvariant="italic">γ</mml:mi></mml:math></inline-formula> in the central point in the Fourier-transformed data and has a variance of <inline-formula><mml:math id="M151" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>n</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula>. The smallest variance <inline-formula><mml:math id="M152" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>n</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula>, which shows no spectral broadening, is chosen for each <inline-formula><mml:math id="M153" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula>. However, it should be noted that these filters are fixed in this work but, in principle, can vary at each <inline-formula><mml:math id="M154" display="inline"><mml:mi>k</mml:mi></mml:math></inline-formula> value or be more sophisticated, such as in adaptive averaging techniques <xref ref-type="bibr" rid="bib1.bibx3 bib1.bibx20" id="paren.19"/>.</p>
      <p id="d2e2582">Spectral leakage occurs when the chosen Gaussian standard deviation <inline-formula><mml:math id="M155" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is more narrow than the spectral bandwidth of the desired signal. As the length of <inline-formula><mml:math id="M156" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> is increased for each segment, the OSR must be increased to maintain the same spectral bandwidth. However, in practice, this is impractical, and, instead, the standard deviation of the filter must be modified to ensure no spectral leakage. This is visually evidenced by a broadening of the linewidth and the reduction in features of the EPR spectrum. By choosing to adjust <inline-formula><mml:math id="M157" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>n</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, the spectral bandwidth will approach that of the whole spectrum as <inline-formula><mml:math id="M158" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> approaches the total length of <inline-formula><mml:math id="M159" display="inline"><mml:mrow><mml:mover accent="true"><mml:mi>x</mml:mi><mml:mo mathvariant="normal" stretchy="false">̃</mml:mo></mml:mover><mml:mo>[</mml:mo><mml:mi>i</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M160" display="inline"><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mo>,</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>,</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:math></inline-formula>), and the SNR improvement will approach that of filtering after concatenation, as employed by Hyde et al. <xref ref-type="bibr" rid="bib1.bibx8" id="paren.20"/>.</p>
      <p id="d2e2666">Since the optimum windowing method for the SOFFA algorithm is rectangular, abrupt discontinuities may exist in field space as the data are collected segmentally. Discontinuities cause Sinc-like features in Fourier space. However, Fourier filtering each segment with an FIR Gaussian filter removes these discontinuities and produces smooth overlap and concatenation. Filtering each segment separately removes the need for filtering the periodic noise associated with the step, as in <xref ref-type="bibr" rid="bib1.bibx8" id="text.21"/>, which is required if the spectrum is filtered after concatenation.</p>
      <p id="d2e2673">As <inline-formula><mml:math id="M161" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> increases, the length of the tail further overlaps with the head of multiple segments, resulting in averaging.</p>
</sec>
<sec id="Ch1.S3.SS3">
  <label>3.3</label><title>Segment-overlap averaging</title>
      <p id="d2e2691">If a signal input is infinitely long or for signals that need to be filtered in real time, the overlap-add method is used with short-time Fourier transform (STFT) block-filtering for efficient digital signal processing <xref ref-type="bibr" rid="bib1.bibx23 bib1.bibx10" id="paren.22"/>. Block-filtering breaks a long or continuous signal <inline-formula><mml:math id="M162" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> into a series of spectral windows with a fixed discrete length. Each window is filtered individually in Fourier space and concatenated back together, as illustrated in Fig. <xref ref-type="fig" rid="F3"/>A. Finally, the output of block-filtering and recombining the data with an overlap-add or overlap-save method is equivalent to filtering the long-signal <inline-formula><mml:math id="M163" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> data directly. In the case of the SOFFA method, illustrated in Fig. <xref ref-type="fig" rid="F3"/>B, each component is acquired separately.</p>

      <fig id="F3"><label>Figure 3</label><caption><p id="d2e2731"><bold>(A)</bold> The overlap-add filter design is used for a large time domain signal <inline-formula><mml:math id="M164" display="inline"><mml:mrow><mml:mi>x</mml:mi><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, where it is discretized <inline-formula><mml:math id="M165" display="inline"><mml:mrow><mml:mover accent="true"><mml:mi>x</mml:mi><mml:mo mathvariant="normal" stretchy="false">̃</mml:mo></mml:mover><mml:mo>[</mml:mo><mml:mi>i</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> and segmented by delayed blocks <inline-formula><mml:math id="M166" display="inline"><mml:mi mathvariant="normal">Δ</mml:mi></mml:math></inline-formula>. Each discretized window is Fourier filtered by <inline-formula><mml:math id="M167" display="inline"><mml:mrow><mml:mtext>H</mml:mtext><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> and concatenated. <bold>(B)</bold> In a segmented magnetic resonance experiment, each overlapped segment has noise that is uncorrelated. Each segment is discretized separately and Fourier filtered by <inline-formula><mml:math id="M168" display="inline"><mml:mrow><mml:mtext>H</mml:mtext><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula>, and overlapping segments are further averaged during concatenation. Without overlap (<inline-formula><mml:math id="M169" display="inline"><mml:mrow><mml:mi>L</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mi>n</mml:mi></mml:mrow></mml:math></inline-formula>), the methods of <bold>(A)</bold> and <bold>(B)</bold> are equivalent.</p></caption>
          <graphic xlink:href="https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026-f03.png"/>

        </fig>

      <p id="d2e2832">For overlap-add processing in SOFFA, a high-resolution overlap-add grid is constructed at 4 times the target resolution, with <inline-formula><mml:math id="M170" display="inline"><mml:mrow><mml:mn mathvariant="normal">4</mml:mn><mml:mi>P</mml:mi></mml:mrow></mml:math></inline-formula> evenly spaced points spanning the full field range <inline-formula><mml:math id="M171" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula>. Each acquired segment <inline-formula><mml:math id="M172" display="inline"><mml:mrow><mml:msub><mml:mi>x</mml:mi><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi>j</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> is mapped onto this grid by computing the field position <inline-formula><mml:math id="M173" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mrow><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>F</mml:mi><mml:mtext>first</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:mi>k</mml:mi><mml:mo>⋅</mml:mo><mml:mi>s</mml:mi><mml:mo>+</mml:mo><mml:msub><mml:mi mathvariant="italic">δ</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> for each point <inline-formula><mml:math id="M174" display="inline"><mml:mi>j</mml:mi></mml:math></inline-formula>, where <inline-formula><mml:math id="M175" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">δ</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the field offset of point <inline-formula><mml:math id="M176" display="inline"><mml:mi>j</mml:mi></mml:math></inline-formula> within the segment sweep. The value <inline-formula><mml:math id="M177" display="inline"><mml:mrow><mml:msub><mml:mi>x</mml:mi><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi>j</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> is accumulated into the nearest grid bin, and a count is incremented. After all <inline-formula><mml:math id="M178" display="inline"><mml:mi>K</mml:mi></mml:math></inline-formula> segments have been processed, each bin is divided by its count to yield the averaged value, and bins with no contributions are filled by linear interpolation from neighboring bins. This accumulation and averaging step is where the segment-overlap averaging takes place on the fine grid.</p>
      <p id="d2e2958">Once each segment is successfully filtered, the segments must be concatenated together. Due to the use of a rectangular window, the segments can be concatenated in Fourier space to save processing time, and a single inverse Fourier transform (IFFT) is needed to obtain the discretized spectrum. Because the data are zero-filled and aligned, this is done simply by summation

            <disp-formula id="Ch1.E7" content-type="numbered"><label>7</label><mml:math id="M179" display="block"><mml:mrow><mml:msub><mml:mtext>y</mml:mtext><mml:mtext>tot</mml:mtext></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo><mml:mo>=</mml:mo><mml:mtext>IFFT</mml:mtext><mml:mfenced close=")" open="("><mml:mrow><mml:munderover><mml:mo movablelimits="false">∑</mml:mo><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn></mml:mrow><mml:mrow><mml:mi>K</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:munderover><mml:msub><mml:mtext>Y</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo><mml:msub><mml:mtext>H</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:mfenced><mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>

          Since each of the segments has a portion of the signal and non-coherent noise that lies within the spectral bandwidth (low frequency), an SNR improvement of <inline-formula><mml:math id="M180" display="inline"><mml:msqrt><mml:mi>m</mml:mi></mml:msqrt></mml:math></inline-formula> is expected by averaging the overlapped segments.</p>
      <p id="d2e3033">When a fixed filter (i.e., the same filter used on each segment) is employed and each block is recombined using the overlap-add or overlap-save algorithm, the SNR of the filtered signal is exactly equivalent as if the  significantly oversampled whole signal was processed directly.</p>
      <p id="d2e3036">Finally, the first and last <inline-formula><mml:math id="M181" display="inline"><mml:mi>L</mml:mi></mml:math></inline-formula> points are called the head and tail, respectively. Since the head and tail do not have a complete segment-overlap dataset, they must be removed. As <inline-formula><mml:math id="M182" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> increases, the head and tail regions may encroach on the magnetic resonance signal. In practice, for large values of <inline-formula><mml:math id="M183" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>, the total sweep width should be increased to accommodate for the removal of the head and tail region.</p>
</sec>
<sec id="Ch1.S3.SS4">
  <label>3.4</label><title>Decimation</title>
      <p id="d2e3069">The total number of points in the final concatenated spectrum <inline-formula><mml:math id="M184" display="inline"><mml:mrow><mml:msub><mml:mi>y</mml:mi><mml:mtext>tot</mml:mtext></mml:msub><mml:mo>[</mml:mo><mml:mi>i</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> is a function of the oversampling rate, the step size, and the number of steps. To generate a SOFFA spectrum with a conventional number of output points <inline-formula><mml:math id="M185" display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula> (for example, 512, 1024, 2048, or 4096), the filtered grid is decimated to <inline-formula><mml:math id="M186" display="inline"><mml:mi>P</mml:mi></mml:math></inline-formula> output points using a moving-average window, where each output point is the mean of a fixed number of neighboring fine-grid points centered on the corresponding output field position. This produces the final output spectrum <inline-formula><mml:math id="M187" display="inline"><mml:mrow><mml:mi>y</mml:mi><mml:mo>[</mml:mo><mml:mi>p</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M188" display="inline"><mml:mrow><mml:mi>p</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>,</mml:mo><mml:mi>P</mml:mi><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:math></inline-formula>. The decimation step conserves the SNR gains achieved during Fourier block-filtering and segment-overlap averaging. In addition, the moving-average window acts as a final low-pass filter on the fine grid while reducing the number of points to a standard (typically 1024).</p>
</sec>
<sec id="Ch1.S3.SS5">
  <label>3.5</label><title>Implementation</title>
      <p id="d2e3149">The block-filtering approach employed by the SOFFA method provides flexibility in filter design. If the filter <inline-formula><mml:math id="M189" display="inline"><mml:mrow><mml:mtext>H</mml:mtext><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> is constant, as in this work, the output <inline-formula><mml:math id="M190" display="inline"><mml:mrow><mml:mi>y</mml:mi><mml:mo>[</mml:mo><mml:mi>i</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> is equivalent whether block-filtering is used or the oversampled data are filtered after concatenation but before decimation. One must be careful to always filter before decimation to not reduce the filtering effectiveness. If the filter varies per segment <inline-formula><mml:math id="M191" display="inline"><mml:mrow><mml:msub><mml:mtext>H</mml:mtext><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> then filtering after concatenation is no longer equivalent <xref ref-type="bibr" rid="bib1.bibx17 bib1.bibx12" id="paren.23"/>. There is no direct analogue in conventional CW averaging to segment-specific filtering because a full sweep is processed as a single globally averaged trace, whereas SOFFA permits each independently acquired segment to be denoised with its own locally appropriate filter, for example by applying a Wiener filter separately to each segment before recombination <xref ref-type="bibr" rid="bib1.bibx23" id="paren.24"/>.</p>
      <p id="d2e3203">In general, the SOFFA method splits data processing into two complementary operations: (i) high-frequency filtering and noise shaping and (ii) low-frequency averaging.</p>
<sec id="Ch1.S3.SS5.SSS1">
  <label>3.5.1</label><title>Segmented continuous-wave EPR</title>
      <p id="d2e3214">A SOFFA-CW experiment is performed by collecting oversampled data from a standard lock-in phase-sensitive detector over a fraction of the spectrum and systematically stepping the center field to obtain the full signal. In practice all parameters kept the same as the traditional CW experiment. The number of points is set to 4096 or 8192, the time constant is significantly reduced to minimize lock-in noise correlation, and scan rate should be adjusted to optimize the oversampled segments to ensure no broadening from passage. One rule of thumb is to use the same sweep rate as the traditional experiment and to make the time per Gauss constant over the truncated segment (e.g., 60 s for 10 <inline-formula><mml:math id="M192" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> and 12 s for 2 <inline-formula><mml:math id="M193" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>; 0.167 <inline-formula><mml:math id="M194" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi><mml:mspace linebreak="nobreak" width="0.125em"/><mml:msup><mml:mi mathvariant="normal">s</mml:mi><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>). The spectral bandwidth of a CW experiment is larger compared to the partial line shapes acquired with SOFFA, allowing for improved filtering of the high-frequency noise.</p>
</sec>
<sec id="Ch1.S3.SS5.SSS2">
  <label>3.5.2</label><title>Segmented non-adiabatic rapid scan</title>
      <p id="d2e3259">In SOFFA-NARS the continuous field sweep of CW is replaced by a stationary field position at which a large-amplitude, slow-rate sinusoidal or trapezoidal modulation drives the spin system through resonance repeatedly. Because <inline-formula><mml:math id="M195" display="inline"><mml:mrow><mml:mi mathvariant="normal">d</mml:mi><mml:msub><mml:mi>B</mml:mi><mml:mi>m</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:mi mathvariant="normal">d</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:math></inline-formula> is slow enough that the spin system remains in thermal equilibrium throughout, no passage effects occur, and all harmonics of the modulation frequency are collected coherently by a digitizer, yielding a pure-absorption spectrum after processing <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx8 bib1.bibx13" id="paren.25"/>. The static field is then stepped, and the process is repeated across the full spectrum.</p>
      <p id="d2e3284">This architecture cleanly replaces the CW sweep rate constraint with two independent parameters: modulation amplitude, which sets the spectral window sampled at each field position and therefore maps directly onto the segment width <inline-formula><mml:math id="M196" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula>, and modulation frequency, which determines both the time resolution per cycle and the number of modulation cycles collected per segment. Longer dwell time per field position means more cycles, more comb filtering, and a lower noise floor at the cost of the total experiment time.</p>
      <p id="d2e3294">The key advantage over SOFFA-CW is that the step size <inline-formula><mml:math id="M197" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> and modulation amplitude (segment size <inline-formula><mml:math id="M198" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula>) can be reduced independently of any magnet sweep rate or hysteresis constraint since the magnet is stationary during acquisition. This removes the hardware floor on sweep time as the binding limit and shifts the practical ceiling to the modulation frequency stability and digitizer dynamic range instead.</p>
      <p id="d2e3311">The step size should be set such that significant overlap occurs (<inline-formula><mml:math id="M199" display="inline"><mml:mrow><mml:mi>L</mml:mi><mml:mo>&gt;</mml:mo><mml:mn mathvariant="normal">20</mml:mn><mml:mi>n</mml:mi></mml:mrow></mml:math></inline-formula>). For NARS spectroscopy, pure absorption is directly collected, providing the optimal spectral bandwidth for SOFFA. Multiple time averaging (MTA) is standard in NARS due to the rapid data collection rate and filters low-frequency and shot noise associated with environmental sources <xref ref-type="bibr" rid="bib1.bibx37 bib1.bibx4" id="paren.26"/>. No change in the NARS collection procedure is required to implement SOFFA-NARS processing.</p>
</sec>
<sec id="Ch1.S3.SS5.SSS3">
  <label>3.5.3</label><title>Frequency-stepped NMR</title>
      <p id="d2e3339">Frequency stepping is used to obtain broadband <xref ref-type="bibr" rid="bib1.bibx25" id="paren.27"/> or ultra-wideband <xref ref-type="bibr" rid="bib1.bibx27" id="paren.28"/> NMR spectra for exotic <xref ref-type="bibr" rid="bib1.bibx1 bib1.bibx21 bib1.bibx18" id="paren.29"/> and quadrupolar nuclei <xref ref-type="bibr" rid="bib1.bibx19" id="paren.30"/>, including applications with magic-angle spinning <xref ref-type="bibr" rid="bib1.bibx24" id="paren.31"/>. A narrow-band variant of this approach, in which the frequency is stepped to produce a series of segmented spectra, is compatible with the SOFFA method.</p>
</sec>
<sec id="Ch1.S3.SS5.SSS4">
  <label>3.5.4</label><title>General usage and parameter selection</title>
      <p id="d2e3365">Collection of SOFFA data requires the ability to step one parameter in known increments and relate these to a fixed number of points per segment and also requires that the signal of interest is stationary and repeatable in that parameter. Table <xref ref-type="table" rid="T2"/> compares the parameters for a conventional EPR CW experiment and a SOFFA-CW experiment. A traditional CW spectrum should first be collected to determine the full magnetic field sweep width of the EPR signal. In modern EPR software (e.g., Bruker XEPR, Bruker MS5000, SpecMan), it is straightforward to derive the required parameters from the configured number of points.</p>
      <p id="d2e3370">For a SOFFA-CW experiment, a separate experimental configuration is created, starting at the lowest magnetic field. In the example of Fig. <xref ref-type="fig" rid="F4"/>, the SOFFA-CW segment sweep width is set to one-quarter of the total sweep (25 <inline-formula><mml:math id="M200" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>), with 4096 points per segment. The time constant should be set to the minimum available value to avoid pre-filtering within each segment. The experimental scan time per segment (30 s) is set to <inline-formula><mml:math id="M201" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">200</mml:mn></mml:mrow></mml:math></inline-formula>th of the total CW experiment time to match the total SOFFA-CW acquisition time. Further averaging of the full SOFFA-CW dataset is always possible; however, the overlap between segments already provides built-in averaging (overlap <inline-formula><mml:math id="M202" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">48</mml:mn></mml:mrow></mml:math></inline-formula> in this example).</p>
      <p id="d2e3407">In the ProDEL code<sup>1</sup>, three variables need to be set: the starting field (one step below the lowest field) is placed in <monospace>value</monospace>, the final field is placed in <monospace>endParValue</monospace>, and the segment step is placed in <monospace>parStep</monospace>. Bruker XEPR then executes the ProDEL script on the active experiment. The data are saved by XEPR, and the acquired segments are loaded into the Python GUI<sup>1</sup>, and the filter variance is adjusted to ensure no spectral broadening.</p>

<table-wrap id="T2"><label>Table 2</label><caption><p id="d2e3441">Comparison of parameters required for a traditional CW experiment and a SOFFA-CW experiment. The traditional time constant (RC filter) should be set as low as possible for SOFFA-CW. Total scan times do not include overhead (e.g., field flyback time, program latency).</p></caption><oasis:table frame="topbot"><oasis:tgroup cols="3">
     <oasis:colspec colnum="1" colname="col1" align="left"/>
     <oasis:colspec colnum="2" colname="col2" align="left"/>
     <oasis:colspec colnum="3" colname="col3" align="left"/>
     <oasis:thead>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">Traditional CW</oasis:entry>
         <oasis:entry colname="col3">SOFFA-CW</oasis:entry>
       </oasis:row>
     </oasis:thead>
     <oasis:tbody>
       <oasis:row>
         <oasis:entry colname="col1">Sweep width  (<inline-formula><mml:math id="M205" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">100 <inline-formula><mml:math id="M206" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">100 <inline-formula><mml:math id="M207" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Power</oasis:entry>
         <oasis:entry colname="col2">0.6325 <inline-formula><mml:math id="M208" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">0.6325 <inline-formula><mml:math id="M209" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Mod. amp.</oasis:entry>
         <oasis:entry colname="col2">0.5 <inline-formula><mml:math id="M210" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
         <oasis:entry colname="col3">0.5 <inline-formula><mml:math id="M211" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">No. of pts (<inline-formula><mml:math id="M212" display="inline"><mml:mi>N</mml:mi></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">4096</oasis:entry>
         <oasis:entry colname="col3">4096</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Scan time   (<inline-formula><mml:math id="M213" display="inline"><mml:mi mathvariant="italic">τ</mml:mi></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">240 s</oasis:entry>
         <oasis:entry colname="col3">30 s</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Aves.</oasis:entry>
         <oasis:entry colname="col2">25</oasis:entry>
         <oasis:entry colname="col3">1</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Time constant</oasis:entry>
         <oasis:entry colname="col2">58.59 ms</oasis:entry>
         <oasis:entry colname="col3">–</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Filter (<inline-formula><mml:math id="M214" display="inline"><mml:mi mathvariant="italic">σ</mml:mi></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">–</oasis:entry>
         <oasis:entry colname="col3">50</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Seg. width (<inline-formula><mml:math id="M215" display="inline"><mml:mi>g</mml:mi></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">–</oasis:entry>
         <oasis:entry colname="col3">25 <inline-formula><mml:math id="M216" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row rowsep="1">
         <oasis:entry colname="col1">Seg. step  (<inline-formula><mml:math id="M217" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula>)</oasis:entry>
         <oasis:entry colname="col2">–</oasis:entry>
         <oasis:entry colname="col3">0.5 <inline-formula><mml:math id="M218" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1">Total exp. time</oasis:entry>
         <oasis:entry colname="col2"><inline-formula><mml:math id="M219" display="inline"><mml:mrow><mml:mi>t</mml:mi><mml:mspace width="0.25em" linebreak="nobreak"/><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> aves.</oasis:entry>
         <oasis:entry colname="col3"><inline-formula><mml:math id="M220" display="inline"><mml:mrow><mml:mi mathvariant="italic">τ</mml:mi><mml:mspace linebreak="nobreak" width="0.25em"/><mml:mo>×</mml:mo></mml:mrow></mml:math></inline-formula> (t s<sup>−1</sup>)</oasis:entry>
       </oasis:row>
       <oasis:row>
         <oasis:entry colname="col1"/>
         <oasis:entry colname="col2">6000 s</oasis:entry>
         <oasis:entry colname="col3">6000 <inline-formula><mml:math id="M222" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula></oasis:entry>
       </oasis:row>
     </oasis:tbody>
   </oasis:tgroup></oasis:table></table-wrap>

      <p id="d2e3754">The SOFFA method is equally applicable to spectra with well-resolved, narrow hyperfine lines. Three parameters govern performance in this regime. First, the Gaussian filter variance <inline-formula><mml:math id="M223" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>n</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula> must be minimized relative to the intrinsic linewidth to prevent spectral broadening. Second, the field step size <inline-formula><mml:math id="M224" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> can be reduced to increase the overlap factor <inline-formula><mml:math id="M225" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula> and thus the number of averaged segments; on the Bruker E500, <inline-formula><mml:math id="M226" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> is practically limited to 0.01 <inline-formula><mml:math id="M227" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> and conservatively to 0.025 <inline-formula><mml:math id="M228" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> by the field controller precision and magnet hysteresis. Fine adjustment of the effective averaging is therefore most conveniently achieved by varying <inline-formula><mml:math id="M229" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula>, while larger gains are better obtained by repeating the full segment stack (repetitions). Third, the per-segment scan rate should not exceed the effective rate of a conventional full-sweep experiment: for example, a 10 <inline-formula><mml:math id="M230" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> sweep collected over 60 s implies that each 2 <inline-formula><mml:math id="M231" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> segment should require at least 12 s.</p>
      <p id="d2e3831">For a fixed Gaussian filter, the combined SNR improvement of the SOFFA method is the product of the oversampling gain and the segment-overlap averaging gain <inline-formula><mml:math id="M232" display="inline"><mml:msqrt><mml:mrow><mml:mi>m</mml:mi><mml:mo>⋅</mml:mo><mml:mtext>OSR</mml:mtext></mml:mrow></mml:msqrt></mml:math></inline-formula>. Substituting <inline-formula><mml:math id="M233" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>=</mml:mo><mml:mi>g</mml:mi><mml:mo>/</mml:mo><mml:mi>s</mml:mi></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M234" display="inline"><mml:mrow><mml:mtext>OSR</mml:mtext><mml:mo>=</mml:mo><mml:mo>(</mml:mo><mml:mi>t</mml:mi><mml:mo>/</mml:mo><mml:mi>g</mml:mi><mml:mo>)</mml:mo><mml:mo>⋅</mml:mo><mml:mo>(</mml:mo><mml:mi>L</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>, the product is simplified to

              <disp-formula id="Ch1.E8" content-type="numbered"><label>8</label><mml:math id="M235" display="block"><mml:mrow><mml:msqrt><mml:mrow><mml:mi>m</mml:mi><mml:mo>⋅</mml:mo><mml:mtext>OSR</mml:mtext></mml:mrow></mml:msqrt><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>g</mml:mi><mml:mi>s</mml:mi></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>t</mml:mi><mml:mi>g</mml:mi></mml:mfrac></mml:mstyle><mml:mo>⋅</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>L</mml:mi><mml:mi>N</mml:mi></mml:mfrac></mml:mstyle></mml:mrow></mml:msqrt><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:mi>K</mml:mi><mml:mo>⋅</mml:mo><mml:mstyle displaystyle="true"><mml:mfrac style="display"><mml:mi>L</mml:mi><mml:mi>N</mml:mi></mml:mfrac></mml:mstyle></mml:mrow></mml:msqrt><mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>

            and so the theoretical upper bound on SNR improvement is <inline-formula><mml:math id="M236" display="inline"><mml:msqrt><mml:mrow><mml:mi>K</mml:mi><mml:mo>⋅</mml:mo><mml:mi>L</mml:mi><mml:mo>/</mml:mo><mml:mi>N</mml:mi></mml:mrow></mml:msqrt></mml:math></inline-formula>, the square root of the total number of acquired data points across all segments normalized to the conventional spectrum length. This is equivalent to the SNR that would be achieved by collecting a single continuous sweep of <inline-formula><mml:math id="M237" display="inline"><mml:mrow><mml:mi>K</mml:mi><mml:mo>⋅</mml:mo><mml:mi>L</mml:mi></mml:mrow></mml:math></inline-formula> points in the same total experiment time and represents the limit at which SOFFA converges to conventional filtered averaging. This assumes that the filtering, measurement time, and decimation are equivalent.</p>
      <p id="d2e3982">Three practical constraints prevent this limit from being reached in full. First, the minimum magnet step size <inline-formula><mml:math id="M238" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula> (conservatively 0.25 G and at best 0.1 G on the Bruker E500) places a ceiling on <inline-formula><mml:math id="M239" display="inline"><mml:mi>K</mml:mi></mml:math></inline-formula> as set by the field controller precision and magnet hysteresis. Second, the per-segment sweep rate must remain below the threshold for adiabatic passage effects, which constrains how rapidly the field can be stepped through any given segment. Third, <inline-formula><mml:math id="M240" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise imposes a lower bound on useful segment length: if segments are shortened beyond the correlation length of the low-frequency noise, the decorrelation assumption underlying the <inline-formula><mml:math id="M241" display="inline"><mml:msqrt><mml:mi>m</mml:mi></mml:msqrt></mml:math></inline-formula> averaging gain begins to break down. Within these hardware constraints, SOFFA approaches but cannot exceed the SNR of a hypothetical instrument with no step size or memory limitations. For a fixed filter, the hardware is the ceiling, not the algorithm.</p>
      <p id="d2e4019">An additional advantage of segmented data collection is noted. By breaking the acquisition into rapid, localized segments, the SOFFA algorithm acts as a hardware-level high-pass filter that systematically prevents the long-term accumulation of <inline-formula><mml:math id="M242" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula>-correlated low-frequency drift.</p>
      <p id="d2e4034">For strictly white noise, once the oversampling ratio and filter are aggressive enough to reject all out-of-band noise down to negligible levels (while still preserving the physical EPR lineshape), any further increase in the OSR or decimation factor provides no additional benefit. One cannot filter out noise that resides within the exact same frequency band as the EPR signal without destroying the signal itself; that is left to averaging, which scales by <inline-formula><mml:math id="M243" display="inline"><mml:msqrt><mml:mi>m</mml:mi></mml:msqrt></mml:math></inline-formula>.</p>
      <p id="d2e4046">By restructuring the acquisition chain, the algorithm successfully decouples high-frequency filtering from low-frequency averaging. The high-frequency broadband noise is aggressively filtered out at the local segment level by leveraging the massive oversampling density, while the low-frequency <inline-formula><mml:math id="M244" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> drift is mitigated through the rapid scanning and subsequent spatial averaging of the overlapping segments. Because these two distinct noise domains are handled by two separate, optimized mechanisms, the method provides a data collection scheme that drastically suppresses correlated noise and extends sensitivity toward the limits imposed by practical hardware step size, lock-in amplifier memory limits, and sweep-rate constraints.</p>
</sec>
</sec>
</sec>
<sec id="Ch1.S4">
  <label>4</label><title>Results and discussion</title>
      <p id="d2e4071">The following experiments were tested using the SOFFA method described above.</p>
<sec id="Ch1.S4.SS1">
  <label>4.1</label><title>Continuous-wave EPR</title>
      <p id="d2e4081">A series of CW EPR spectra of apo [FeFe]-hydrogenase from <italic>Chlamydomonas reinhardtii</italic> of varying concentrations were collected using a bismuth germanate (<inline-formula><mml:math id="M245" display="inline"><mml:mrow class="chem"><mml:msub><mml:mi mathvariant="normal">Bi</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:mo>(</mml:mo><mml:msub><mml:mi mathvariant="normal">GeO</mml:mi><mml:mn mathvariant="normal">4</mml:mn></mml:msub><mml:msub><mml:mo>)</mml:mo><mml:mn mathvariant="normal">3</mml:mn></mml:msub></mml:mrow></mml:math></inline-formula>, BGO) dielectric resonator retrofitted in a Bruker MD5 housing <xref ref-type="bibr" rid="bib1.bibx11" id="paren.32"/>. The apo protein has one reduced <inline-formula><mml:math id="M246" display="inline"><mml:mrow class="chem"><mml:mo>[</mml:mo><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">Fe</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">S</mml:mi><mml:msup><mml:mo>]</mml:mo><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> cluster with an effective <inline-formula><mml:math id="M247" display="inline"><mml:mrow><mml:mi mathvariant="normal">S</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mn mathvariant="normal">2</mml:mn></mml:mrow></mml:math></inline-formula>. Three concentrations of 1 mM, 100 <inline-formula><mml:math id="M248" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula>, and 10 <inline-formula><mml:math id="M249" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> were prepared and confirmed with UV-VIS by measuring the characteristic 400 nm feature indicating relative amounts of <inline-formula><mml:math id="M250" display="inline"><mml:mrow class="chem"><mml:mo>[</mml:mo><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">Fe</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">S</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> <xref ref-type="bibr" rid="bib1.bibx16" id="paren.33"/>.</p>
      <p id="d2e4196">The 100 <inline-formula><mml:math id="M251" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> CW spectrum yielded a SNR of 181.8, while the SNR of the 10 <inline-formula><mml:math id="M252" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> CW spectrum was calculated to be 16.5. For SOFFA-CW, an SNR improvement of 6.1 (<inline-formula><mml:math id="M253" display="inline"><mml:mrow><mml:mn mathvariant="normal">1114</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">181.8</mml:mn></mml:mrow></mml:math></inline-formula>) is exhibited between the 100 <inline-formula><mml:math id="M254" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> CW experiment and the SOFFA-CW experiment. On the other hand, the SOFFA-CW experiment with 10 <inline-formula><mml:math id="M255" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> concentration had an SNR ratio that was calculated to be 83.8 and an SNR improvement of 5.1 (<inline-formula><mml:math id="M256" display="inline"><mml:mrow><mml:mn mathvariant="normal">83.8</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">16.5</mml:mn></mml:mrow></mml:math></inline-formula>). An average of 5.6 increase in concentration sensitivity is shown for the two concentrations using SOFFA-CW.</p>

      <fig id="F4"><label>Figure 4</label><caption><p id="d2e4266">CW spectra were collected on a Bruker E5180 X-band bridge with a dielectric resonator (9.70 GHz) of the reduced <inline-formula><mml:math id="M257" display="inline"><mml:mrow class="chem"><mml:mo>[</mml:mo><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">Fe</mml:mi><mml:mtext>-</mml:mtext><mml:mn mathvariant="normal">4</mml:mn><mml:mi mathvariant="normal">S</mml:mi><mml:msup><mml:mo>]</mml:mo><mml:mo>+</mml:mo></mml:msup></mml:mrow></mml:math></inline-formula> of apo [FeFe]-hydrogenase from <italic>Chlamydomonas reinhardtii</italic> at 1 mM, 100 <inline-formula><mml:math id="M258" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula>, and 10 <inline-formula><mml:math id="M259" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> concentrations – spectrum i, ii, and iii, respectively. The reference spectrum of 1 mM concentration was collected over 100 <inline-formula><mml:math id="M260" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>, 4 min scans averaged nine times with 4096 points. The traditional CW experiment with 100 <inline-formula><mml:math id="M261" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> concentration was collected over 100 <inline-formula><mml:math id="M262" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>, 4 min scans averaged 25 times with 4096 points for a total time of 100 min. Both CW spectra were filtered with a <inline-formula><mml:math id="M263" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>n</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn mathvariant="normal">75</mml:mn></mml:mrow></mml:math></inline-formula>. The SOFFA-CW experiment with 100 <inline-formula><mml:math id="M264" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> concentration was collected in 0.5 <inline-formula><mml:math id="M265" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> steps of 25 <inline-formula><mml:math id="M266" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> over 30 s and 4096 points for a total time of 100 min. The SOFFA-CW experiment with 10 <inline-formula><mml:math id="M267" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> concentration was collected in 0.5 <inline-formula><mml:math id="M268" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> steps of 25 <inline-formula><mml:math id="M269" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> over 30 s and 4096 points for a total time of 100 min. For both SOFFA-CW experiments, a total of 200 steps were collected over a 100 <inline-formula><mml:math id="M270" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> total sweep. All segments were block filtered with a <inline-formula><mml:math id="M271" display="inline"><mml:mrow><mml:mi mathvariant="italic">σ</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">50</mml:mn></mml:mrow></mml:math></inline-formula> and with an <inline-formula><mml:math id="M272" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">48</mml:mn></mml:mrow></mml:math></inline-formula>. All spectra were collected at a temperature of 15 K and at an incident power of 0.63 <inline-formula><mml:math id="M273" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula>, with a field modulation amplitude of 0.5 <inline-formula><mml:math id="M274" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>. The EPR feature at 340 <inline-formula><mml:math id="M275" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> (<inline-formula><mml:math id="M276" display="inline"><mml:mo lspace="0mm">∗</mml:mo></mml:math></inline-formula>) is a background caused by an unknown radical in the shield of the MD5.  </p></caption>
          <graphic xlink:href="https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026-f04.png"/>

        </fig>

</sec>
<sec id="Ch1.S4.SS2">
  <label>4.2</label><title>Non-adiabatic rapid scan</title>
      <p id="d2e4488">Conventional CW data are compared to SOFFA-NARS of a 150 <inline-formula><mml:math id="M277" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> site-directed spin-labeled hemoglobin sample in 82 % glycerol (18 <inline-formula><mml:math id="M278" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">°</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula>) at X-band (9.81 GHz), shown in Fig. <xref ref-type="fig" rid="F5"/>. Experimental parameters are stated in the figure caption. This sample is in the slow-tumbling regime of approximately <inline-formula><mml:math id="M279" display="inline"><mml:mrow><mml:mn mathvariant="normal">15</mml:mn><mml:mo>×</mml:mo><mml:msup><mml:mn mathvariant="normal">10</mml:mn><mml:mrow><mml:mo>-</mml:mo><mml:mn mathvariant="normal">9</mml:mn></mml:mrow></mml:msup><mml:mspace linebreak="nobreak" width="0.125em"/><mml:mrow class="unit"><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:mrow></mml:math></inline-formula> rotational correlation time <inline-formula><mml:math id="M280" display="inline"><mml:mrow><mml:msub><mml:mi mathvariant="italic">τ</mml:mi><mml:mtext>corr</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>. After 16 averages of 2 min scans, a CW SNR of 9.9 is realized. Adding a Gaussian filter increases the SNR by a factor of 4.7 (<inline-formula><mml:math id="M281" display="inline"><mml:mrow><mml:mn mathvariant="normal">46.9</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">9.9</mml:mn></mml:mrow></mml:math></inline-formula>). By processing the segmented-NARS data with the SOFFA filtering method, the collected pure-absorption signal has an SNR of 3890 (data omitted). In order to display the spectrum in a more conventional form, the first derivative is computed using an MDIFF pseudo-modulation of 0.1 <inline-formula><mml:math id="M282" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>. An SNR increase of 10.3 (<inline-formula><mml:math id="M283" display="inline"><mml:mrow><mml:mn mathvariant="normal">483.3</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">46.9</mml:mn></mml:mrow></mml:math></inline-formula> compared to the filtered CW data) was achieved for the same measurement time of 32 min. The zoomed inset is the first 500 points of the NARS signal multiplied by a factor of 50. Since NARS uses a balanced mixer and an A/D converter, the dispersion signal was also collected for no increase in measurement time (data omitted). The NARS linear background was baseline-corrected in Xepr.</p>

      <fig id="F5"><label>Figure 5</label><caption><p id="d2e4581">A 150 <inline-formula><mml:math id="M284" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> site-directed spin-labeled hemoglobin sample in 82 % glycerol at 18 <inline-formula><mml:math id="M285" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">°</mml:mi><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> is collected with conventional-CW EPR in a five-loop–four-gap loop–gap resonator at X-band (9.81 GHz) using 0.1 <inline-formula><mml:math id="M286" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> field modulation at a rate of 100 kHz and a 5 ms time constant, with 16 averages over 20 <inline-formula><mml:math id="M287" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> (2 min scan) at 1 <inline-formula><mml:math id="M288" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula> of microwave power, yielding an SNR of 9.9. A Gaussian filter is applied to the CW data, yielding an SNR of 46.9. SOFFA-NARS data are collected with 0.025 <inline-formula><mml:math id="M289" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> steps (<inline-formula><mml:math id="M290" display="inline"><mml:mi>s</mml:mi></mml:math></inline-formula>), an overlap of <inline-formula><mml:math id="M291" display="inline"><mml:mrow><mml:mi>m</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">40</mml:mn></mml:mrow></mml:math></inline-formula> using a trapezoidal field ramp of 11.33 kHz with a 50 <inline-formula><mml:math id="M292" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:mrow></mml:math></inline-formula> flat region, and an amplitude of 0.5 <inline-formula><mml:math id="M293" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula>. Data were acquired over 95 % of the trapezoidal sweep in one direction. Processing the data with the SOFFA method results in an SNR of the pure-absorption signal (not shown) of 3890. An MDIFF pseudo-modulation of 0.1 <inline-formula><mml:math id="M294" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> field modulation equivalent was used to display the spectrum in a more conventional form, yielding an SNR of 483.3. The zoomed inset is the first 500 points of the NARS signal. Data were collected on a custom-built X-band bridge dedicated to segmented-NARS spectroscopy. An NARS dispersion signal was also collected (not shown). Both experiments took approximately 32 min each.</p></caption>
          <graphic xlink:href="https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026-f05.png"/>

        </fig>

</sec>
<sec id="Ch1.S4.SS3">
  <label>4.3</label><title>Practical considerations</title>
      <p id="d2e4696">The SNR ratio of EPR is fundamental to the usefulness of the technique. Improvements in EPR fall into three categories: technical developments, such as resonator and spectrometer advances; multiharmonic data collection <xref ref-type="bibr" rid="bib1.bibx39" id="paren.34"/>; and advanced averaging and filtering techniques, such as, wavelet analysis <xref ref-type="bibr" rid="bib1.bibx29" id="paren.35"/> and adaptive averaging <xref ref-type="bibr" rid="bib1.bibx3 bib1.bibx20" id="paren.36"/> techniques. One must take care that any new method does not over-filter and deliver a distorted EPR spectrum.</p>
      <p id="d2e4708">In addition, the evaluation of new technology must be done with both white noise and correlated <inline-formula><mml:math id="M295" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise under consideration. White noise has a flat power spectral density across all frequencies with statistically independent samples, plotted in Fig. <xref ref-type="fig" rid="FA1"/>B spectrum vi. Correlated noise (“pink” or <inline-formula><mml:math id="M296" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise), shown in Fig. <xref ref-type="fig" rid="FA1"/>B, spectrum v, concentrates power at low frequencies that directly overlap with the EPR signal bandwidth, making it impossible to filter without distorting the spectrum. The <inline-formula><mml:math id="M297" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise power spectral density is a function of scan time and is therefore a measure of instrument stability <xref ref-type="bibr" rid="bib1.bibx14" id="paren.37"/>, and changing the sweep speed shifts the correlated noise frequency content relative to the EPR signal bandwidth.</p>
      <p id="d2e4755">For this experiment, the data are plotted in Fig. <xref ref-type="fig" rid="F6"/>A; the <inline-formula><mml:math id="M298" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> lines of 10 <inline-formula><mml:math id="M299" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> TEMPO have been highlighted by using traditional averaging, shown in black, by scanning 400 times over a 273 min time period for an SNR of 1146. In contrast, the same SNR ratio can be achieved in only 20 min (red) without loss of the subtle <inline-formula><mml:math id="M300" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> lines by using the SOFFA-CW method for an SNR of 1218.</p>

      <fig id="F6"><label>Figure 6</label><caption><p id="d2e4797">A 10 <inline-formula><mml:math id="M301" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> TEMPO spectrum was recorded using <bold>(A)</bold> traditional CW averaging for 273 min (400 averages; black) and SOFFA-CW for 20 min (red). One <inline-formula><mml:math id="M302" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> feature is highlighted. The continuous-wave experiment was collected with a 10 <inline-formula><mml:math id="M303" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> sweep of 1024 points over 41.94 s with 400 averages, a 20.48 ms time constant at 3.2 <inline-formula><mml:math id="M304" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula>, and 0.1 <inline-formula><mml:math id="M305" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> field modulation at 100 kHz for an SNR of 1146. SOFFA-CW was performed with a 3 <inline-formula><mml:math id="M306" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> sweep of 8192 points over 10.39 s, with 100 steps of 0.1 <inline-formula><mml:math id="M307" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> each, a 1.28 ms time constant at 3.2 <inline-formula><mml:math id="M308" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mW</mml:mi></mml:mrow></mml:math></inline-formula>, and 0.1 <inline-formula><mml:math id="M309" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">mT</mml:mi></mml:mrow></mml:math></inline-formula> field modulation at 100 kHz for an SNR of 1218. <bold>(B)</bold> Averaged <inline-formula><mml:math id="M310" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> for 400 averages, added to the continuous-wave data (black; SNR of 205); <inline-formula><mml:math id="M311" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> was added onto each of the 100 steps of the SOFFA-CW (red; SNR of 768).</p></caption>
          <graphic xlink:href="https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026-f06.png"/>

        </fig>

      <p id="d2e4916">Since the power spectral density of <inline-formula><mml:math id="M312" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise is similar to the EPR signal, both correlated noise and EPR signal have a similar shape in the field domain, making fitting subtle spectral features difficult without significantly improving the SNR ratio of the EPR signal with hardware improvements since excessively long averaging will not average out <inline-formula><mml:math id="M313" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise.</p>
      <p id="d2e4943">To isolate performance under strictly controlled <inline-formula><mml:math id="M314" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> drift conditions, a hybrid empirical-simulated approach was utilized. Specifically, the empirically acquired EPR spectra shown in Fig. <xref ref-type="fig" rid="F6"/>A were corrupted by mathematically injecting randomly generated <inline-formula><mml:math id="M315" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise into the signal. The noise was implemented in the frequency domain following a <inline-formula><mml:math id="M316" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> power law. The resulting spectrum for the continuous wave is shown in black in Fig. <xref ref-type="fig" rid="F6"/>B.</p>
      <p id="d2e4986">For SOFFA, the randomly generated correlated noise was added to each of the 100 segments, and averaging was performed through the SOFFA algorithm. Since the continuous-wave EPR experiment and the SOFFA-CW experiment have different sweep times (41.49 and 10.39 s, respectively) the frequency content of the correlated noise is different, and this is taken into account in this approach. The resulting spectrum for SOFFA-CW is shown in red in Fig. <xref ref-type="fig" rid="F6"/>B. From this, it is clear that the subtle <inline-formula><mml:math id="M317" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> lines of the 10 <inline-formula><mml:math id="M318" display="inline"><mml:mrow class="unit"><mml:mi mathvariant="normal">µ</mml:mi><mml:mi mathvariant="normal">M</mml:mi></mml:mrow></mml:math></inline-formula> TEMPO are lost in the continuous-wave EPR spectrum and remain in the SOFFA-CW due to the reduction in SNR from 1146 to 205 when <inline-formula><mml:math id="M319" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise was added. The SOFFA method demonstrates enhanced EPR spectral features by not only enhancing the SNR ratio by a factor of 3.7 compared to traditional continuous-wave measurements (<inline-formula><mml:math id="M320" display="inline"><mml:mrow><mml:mn mathvariant="normal">767</mml:mn><mml:mo>:</mml:mo><mml:mn mathvariant="normal">205</mml:mn></mml:mrow></mml:math></inline-formula>) but also effectively mitigating <inline-formula><mml:math id="M321" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> correlated noise, thereby preserving subtle spectral features such as <inline-formula><mml:math id="M322" display="inline"><mml:mrow class="chem"><mml:msup><mml:mi/><mml:mn mathvariant="normal">13</mml:mn></mml:msup><mml:mi mathvariant="normal">C</mml:mi></mml:mrow></mml:math></inline-formula> lines and enabling more reliable spectral fitting even in challenging low-concentration samples where <inline-formula><mml:math id="M323" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> starts to dominate due to averaging requirements.</p>
      <p id="d2e5074">Finally, the version of Bruker Xepr (v.2.6b-160) used to collect the SOFFA spectra is not optimized for segmented data acquisition. Future work will implement segmented-NARS using the Xepr Python API interface to decrease the latency associated with large datasets. An SNR improvement is expected by increasing the number of averages for the same total data collection time. Despite current software limitations, the spectra collections shown in Figs. <xref ref-type="fig" rid="F4"/> and <xref ref-type="fig" rid="F6"/> were performed on a commercial Bruker E500 instrument with no hardware modifications. Further improvement in segmented-NARS is expected by using trapezoidal sweeps and processing both the sweep-up and sweep-down data <xref ref-type="bibr" rid="bib1.bibx13 bib1.bibx33" id="paren.38"/>.</p>
</sec>
</sec>
<sec id="Ch1.S5" sec-type="conclusions">
  <label>5</label><title>Conclusions</title>
      <p id="d2e5094">The SOFFA data acquisition method, introduced herein for segmented magnetic resonance spectroscopy, has been shown to decrease low-frequency background signals and significantly improve the SNR ratio by effectively splitting high-frequency filtering and low-frequency averaging.</p>
      <p id="d2e5097">The improvements described here are phenomenological: the SOFFA method is built upon known DSP foundations, and the SNR gains are demonstrated experimentally rather than derived from a unified analytical model. A quantitative first-principles treatment (one that predicts the net SNR improvement as an explicit function of overlap factor <inline-formula><mml:math id="M324" display="inline"><mml:mi>m</mml:mi></mml:math></inline-formula>, oversampling ratio (OSR), filter variance <inline-formula><mml:math id="M325" display="inline"><mml:mrow><mml:msubsup><mml:mi mathvariant="italic">σ</mml:mi><mml:mi>n</mml:mi><mml:mn mathvariant="normal">2</mml:mn></mml:msubsup></mml:mrow></mml:math></inline-formula>, and noise color) is the subject of ongoing work. Nevertheless, the experimental data presented across three distinct EPR measurement conditions consistently demonstrate the practical value of the approach across biologically relevant samples and measurement conditions. The ProDEL script and Python GUI are publicly available to facilitate adoption.<sup>1</sup></p>
      <p id="d2e5128">The use of the block-filtering approach employed by the SOFFA method provides a flexible framework for implementing complex filter designs. For example, frequency content could be analyzed, and an appropriate filter could be chosen block-wise (<inline-formula><mml:math id="M327" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mi>k</mml:mi></mml:msub><mml:mo>(</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula> where <inline-formula><mml:math id="M328" display="inline"><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn mathvariant="normal">0</mml:mn><mml:mo>,</mml:mo><mml:mn mathvariant="normal">1</mml:mn><mml:mo>,</mml:mo><mml:mi mathvariant="normal">…</mml:mi><mml:mo>,</mml:mo><mml:mi>K</mml:mi></mml:mrow></mml:math></inline-formula>; illustrated in Fig. <xref ref-type="fig" rid="F3"/>) to maximize SNR while minimizing spectral broadening. Future work studying the effects of adaptive filtering and “spectral sensing” is underway in order to be able to choose filter parameters without a priori information <xref ref-type="bibr" rid="bib1.bibx12 bib1.bibx22" id="paren.39"/>. Additionally, the SOFFA method lends itself to more advanced techniques, such as wavelet analysis and filtering <xref ref-type="bibr" rid="bib1.bibx29" id="paren.40"/> or sub-band-multirate filtering <xref ref-type="bibr" rid="bib1.bibx34" id="paren.41"/>, which may yield improved SNR and can be customized with a priori or real-time iterative calculation of the frequency content of the spectrum. Combining advanced filtering techniques with adaptive averaging <xref ref-type="bibr" rid="bib1.bibx3 bib1.bibx2 bib1.bibx20" id="paren.42"/> of the overlapping segments provides a powerful state-of-the-art digital signal processing toolkit for segmented spectroscopy. The SOFFA algorithm also lends itself to multi-harmonic detection without modification <xref ref-type="bibr" rid="bib1.bibx6 bib1.bibx31" id="paren.43"/>.</p>
      <p id="d2e5190">It should be noted that the first field-stepped rapid-scan (RS) spectra were obtained by Eaton and colleagues <xref ref-type="bibr" rid="bib1.bibx38" id="paren.44"/>. However, segmented-RS differs from the enabling field-stepped RS spectra described therein. The work of <xref ref-type="bibr" rid="bib1.bibx38" id="text.45"/> stepped the field while the whole RS spectrum was excited and then averaged together. Potentially, for rapid scan, deconvolution of each segment block-wise before filtering is  feasible <xref ref-type="bibr" rid="bib1.bibx33" id="paren.46"/>. Future work will explore these possibilities.</p>
      <p id="d2e5203">As frequency-swept NARS and RS are more widely adopted, the SOFFA filtering technique introduced here may provide an additional benefit by filtering and averaging signals from the frequency response of microwave components which create large and often quadratic backgrounds <xref ref-type="bibr" rid="bib1.bibx7 bib1.bibx32 bib1.bibx30" id="paren.47"/>. By using the off-resonance frequency or field sweep in the NARS data collection, the large static frequency response can be background-subtracted from the whole dataset before processing without adding significant overhead.</p>
      <p id="d2e5209">Implementing SOFFA-CW on a standard Bruker E500 spectrometer and collecting segmented CW is straightforward and demonstrates an increase in concentration sensitivity of 5.6 for the same measurement time. In a SOFFA-NARS experiment, a factor-of-10.3 SNR improvement, shown in Fig. <xref ref-type="fig" rid="F5"/>, is achieved with no change in the experimental procedure described in the literature <xref ref-type="bibr" rid="bib1.bibx14 bib1.bibx8 bib1.bibx13" id="paren.48"/>.</p>
      <p id="d2e5217">Finally, it should be noted that the theoretical limit of Eq. (<xref ref-type="disp-formula" rid="Ch1.E8"/>)  derived above assumes a fixed Gaussian filter applied uniformly across all segments, and, therefore, assuming no hardware limitations, SOFFA is mathematically equivalent to filtering a single continuous sweep of equivalent length. This effective oversampling makes the SOFFA algorithm especially important for hardware with a fixed maximum number of points. However, this ceiling is specific to that fixed-filter case and does not represent a fundamental bound on the method. Once the filter <inline-formula><mml:math id="M329" display="inline"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mi>k</mml:mi></mml:msub><mml:mo>[</mml:mo><mml:mi mathvariant="italic">ω</mml:mi><mml:mo>]</mml:mo></mml:mrow></mml:math></inline-formula> is allowed to vary per segment, the analogy to a single continuous sweep breaks entirely: there is no continuous-sweep equivalent to a matched or adaptive filter tuned to the local noise statistics of each independently acquired segment. This is not merely a practical distinction because the independent acquisition of each segment is precisely the condition that makes per-segment adaptive denoising statistically valid. Furthermore, the same shortened observation window that decorrelates <inline-formula><mml:math id="M330" display="inline"><mml:mrow><mml:mn mathvariant="normal">1</mml:mn><mml:mo>/</mml:mo><mml:mi>f</mml:mi></mml:mrow></mml:math></inline-formula> noise between segments also provides the locally stationary noise estimate that adaptive filtering requires, meaning the two benefits share a common origin.</p>
      <p id="d2e5251">The collection of segments therefore simultaneously decouples correlated low-frequency noise and unlocks a class of sophisticated denoising strategies with no corollary in conventional continuous-sweep spectroscopy. As adaptive and matched filtering techniques are incorporated into the SOFFA framework, the upper bound on SNR improvement will no longer be set by hardware step size constraints but by the sophistication of the per-segment denoising strategy itself.</p>
</sec>

      
      </body>
    <back><app-group>

<app id="App1.Ch1.S1">
  <label>Appendix A</label><title>Shape of noise</title>
      <p id="d2e5265">Plots of simulated Gaussian spectra in field and Fourier space are shown in Figs. <xref ref-type="fig" rid="FA1"/>A and B, respectively. A noiseless Gaussian is shown in Fig. <xref ref-type="fig" rid="FA1"/>, spectrum i, and white noise is added to make the SNR approximately 4, as shown in Fig. <xref ref-type="fig" rid="FA1"/>, spectrum ii. By filtering the noisy spectrum with a Gaussian filter (Fig. <xref ref-type="fig" rid="FA1"/>B, dashed line) the noise outside of the spectral bandwidth (<inline-formula><mml:math id="M331" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mtext>cw</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>) can be removed, as shown in Fig. <xref ref-type="fig" rid="FA1"/>, spectrum iv. However, by oversampling, shown in Fig. <xref ref-type="fig" rid="FA1"/> spectrum iii, the spectral bandwidth is reduced (<inline-formula><mml:math id="M332" display="inline"><mml:mrow><mml:msub><mml:mi>f</mml:mi><mml:mi mathvariant="normal">s</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>) by the oversampling factor OSF, and the noise power spectral density is reduced by the same amount. In order to mimic the methodology of oversampled segmented-data collection, the number of points remains the same, but the collected data are only a segment with a quarter of the field sweep.</p>
      <p id="d2e5303">An example of pink noise is shown in Fig. <xref ref-type="fig" rid="FA1"/>, spectrum v. The power spectral density, shown in Fig. <xref ref-type="fig" rid="FA1"/>B, illustrates the challenge with filtering pink noise: the concentration of power spectral density in the same region of the spectral bandwidth. On the other hand, white noise, shown in Fig. <xref ref-type="fig" rid="FA1"/> spectrum vi, has a flat power spectral density response.</p>

      <fig id="FA1"><label>Figure A1</label><caption><p id="d2e5314">Simulated field and calculated corresponding Fourier transform employed to illustrate the details of spectral bandwidth. Simulated data are plotted in <bold>(A)</bold> field space and <bold>(B)</bold> truncated Fourier space to provide sufficient detail. Plotted is a (i) noiseless Gaussian spectrum, (ii) Gaussian spectrum with additive white noise, (iii) oversampled Gaussian spectrum with additive white noise (<inline-formula><mml:math id="M333" display="inline"><mml:mrow><mml:mtext>OSR</mml:mtext><mml:mo>=</mml:mo><mml:mn mathvariant="normal">4</mml:mn></mml:mrow></mml:math></inline-formula>), (iv) Fourier-filtered Gaussian spectrum with Gaussian filter (dashed), (v) pink noise with noise floor, and (vi) white noise. </p></caption>
        <graphic xlink:href="https://mr.copernicus.org/articles/7/99/2026/mr-7-99-2026-f07.png"/>

      </fig>

</app>
  </app-group><notes notes-type="codedataavailability"><title>Code and data availability</title>

      <p id="d2e5345">The ProDEL script and Python GUI used to collect and process SOFFA data are available at <uri>https://github.com/jsidabras/SOFFABruker</uri> (last access: 30 June 2026; <ext-link xlink:href="https://doi.org/10.5281/zenodo.20766183" ext-link-type="DOI">10.5281/zenodo.20766183</ext-link>, <xref ref-type="bibr" rid="bib1.bibx28" id="altparen.49"/>).</p>
  </notes><notes notes-type="competinginterests"><title>Competing interests</title>

      <p id="d2e5360">The author has declared that there are no competing interests.</p>
  </notes><notes notes-type="disclaimer"><title>Disclaimer</title>

      <p id="d2e5366">Publisher's note: Copernicus Publications remains neutral with regard to jurisdictional claims made in the text, published maps, institutional affiliations, or any other geographical representation in this paper. The authors bear the ultimate responsibility for providing appropriate place names. Views expressed in the text are those of the authors and do not necessarily reflect the views of the publisher.</p>
  </notes><ack><title>Acknowledgements</title><p id="d2e5373">The author would like to thank Aaron W. Kittell and James S. Hyde for their initial work in the field of non-adiabatic rapid scan and Shannon A. Bonke and Joscha P. Nehrkorn for their helpful discussions. Constanze Sommer is thanked for the apo [FeFe]-hydrogenase sample. The author would also like to thank Wolfgang Lubitz and Dieter Suter for their continued mentoring and Edward J. Reijerse and Alexander Schnegg for their exceptional support, discussions, and encouragement.</p></ack><notes notes-type="financialsupport"><title>Financial support</title>

      <p id="d2e5378">This research has been supported by the European Union Horizon 2020 Marie Skłodowska-Curie Actions (grant no. 745702), the National Institutes of Health, National Institute of General Medical Sciences (grant no. R01GM149568),  the National Institutes of Health, National Institute of Allergy and Infectious Diseases (grant no. U01AI189427), and National Institute of Health (grant no. S10OD036246).</p>
  </notes><notes notes-type="reviewstatement"><title>Review statement</title>

      <p id="d2e5384">This paper was edited by Thomas Prisner and reviewed by two anonymous referees.</p>
  </notes><ref-list>
    <title>References</title>

      <ref id="bib1.bibx1"><label>Ash and Grandinetti(2006)</label><mixed-citation> Ash, J. T. and Grandinetti, P. J.: Solid-state NMR characterization of 69Ga and 71Ga in crystalline solids, Magn. Reson. Chem., 44, 823–831, 2006.</mixed-citation></ref>
      <ref id="bib1.bibx2"><label>Brinton and Hirsh(2010)</label><mixed-citation>Brinton, C. G. and Hirsh, D. J.: Note: Sensitivity enhancement in continuous-wave electron paramagnetic resonance: Adaptive signal averaging versus a moving average, Rev. Sci. Instrum., 81, 026102, <ext-link xlink:href="https://doi.org/10.1063/1.3293381" ext-link-type="DOI">10.1063/1.3293381</ext-link>, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx3"><label>Cochrane and Lenahan(2008)</label><mixed-citation> Cochrane, C. and Lenahan, P.: Real time exponentially weighted recursive least squares adaptive signal averaging for enhancing the sensitivity of continuous wave magnetic resonance, J. Magn. Reson., 195, 17–22, 2008.</mixed-citation></ref>
      <ref id="bib1.bibx4"><label>Eaton et al.(2014)Eaton, Quine, Tseitlin, Mitchell, Rinard, and Eaton</label><mixed-citation>Eaton, S. S., Quine, R. W., Tseitlin, M., Mitchell, D. G., Rinard, G. A., and Eaton, G. R.: Rapid-Scan Electron Paramagnetic Resonance, chap. 2,  3–67, Wiley-Blackwell, <ext-link xlink:href="https://doi.org/10.1002/9783527672431" ext-link-type="DOI">10.1002/9783527672431</ext-link>, 2014.</mixed-citation></ref>
      <ref id="bib1.bibx5"><label>Harris(1978)</label><mixed-citation>Harris, F. J.: On the use of windows for harmonic analysis with the discrete Fourier transform, P. IEEE, 66, 51–83, <ext-link xlink:href="https://doi.org/10.1109/PROC.1978.10837" ext-link-type="DOI">10.1109/PROC.1978.10837</ext-link>, 1978.</mixed-citation></ref>
      <ref id="bib1.bibx6"><label>Hyde et al.(1990)Hyde, Pasenkiewicz-Gierula, Jesmanowicz, and Antholine</label><mixed-citation>Hyde, J. S., Pasenkiewicz-Gierula, M., Jesmanowicz, A., and Antholine, W. E.: Pseudo field modulation in EPR spectroscopy, Appl. Magn. Reson., 1, <ext-link xlink:href="https://doi.org/10.1007/bf03166028" ext-link-type="DOI">10.1007/bf03166028</ext-link>, 1990.</mixed-citation></ref>
      <ref id="bib1.bibx7"><label>Hyde et al.(2010)Hyde, Strangeway, Camenisch, Ratke, and Froncisz</label><mixed-citation> Hyde, J. S., Strangeway, R. A., Camenisch, T. G., Ratke, J. J., and Froncisz, W.: W-band frequency-swept EPR, J. Magn. Reson., 205, 93–101, 2010.</mixed-citation></ref>
      <ref id="bib1.bibx8"><label>Hyde et al.(2013)Hyde, Bennett, Kittell, Kowalski, and Sidabras</label><mixed-citation> Hyde, J. S., Bennett, B., Kittell, A. W., Kowalski, J. M., and Sidabras, J. W.: Moving difference (MDIFF) non-adiabatic rapid sweep (NARS) EPR of copper(II), J. Magn. Reson., 236, 15–25, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx9"><label>Hyde et al.(2022)Hyde, Strangeway, and Sidabras</label><mixed-citation> Hyde, J. S., Strangeway, R. A., and Sidabras, J. W.: Dispersion EPR: Considerations for low-frequency experiments, Appl. Magn. Reson., 53, 193–206, 2022.</mixed-citation></ref>
      <ref id="bib1.bibx10"><label>Ifeachor and Jervis(2002)</label><mixed-citation> Ifeachor, E. and Jervis, B.: Digital Signal Processing: A Practical Approach, Electronic systems engineering series, Prentice Hall, ISBN 13 978-0201544138, 2002.</mixed-citation></ref>
      <ref id="bib1.bibx11"><label>Ivanov et al.(2016)Ivanov, Nadolinny, Bagryanskaya, Grishin, Fedin, and Veber</label><mixed-citation> Ivanov, M. Y., Nadolinny, V. A., Bagryanskaya, E. G., Grishin, Y. A., Fedin, M. V., and Veber, S. L.: Bismuth germanate as a perspective material for dielectric resonators in EPR spectroscopy, J. Magn. Reson., 271, 83–89, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx12"><label>Karami and Saarnisaari(2018)</label><mixed-citation> Karami, E. and Saarnisaari, H.: Windowed overlapped frequency domain block filtering approach for direct sequence signal acquisition, Digit. Commun. Netw., 4, 209–216, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx13"><label>Kittell and Hyde(2015)</label><mixed-citation> Kittell, A. W. and Hyde, J. S.: Spin-label CW microwave power saturation and rapid passage with triangular non-adiabatic rapid sweep (NARS) and adiabatic rapid passage (ARP) EPR spectroscopy, J. Magn. Reson., 255, 68–76, 2015.</mixed-citation></ref>
      <ref id="bib1.bibx14"><label>Kittell et al.(2011)Kittell, Camenisch, Ratke, Sidabras, and Hyde</label><mixed-citation> Kittell, A. W., Camenisch, T. G., Ratke, J. J., Sidabras, J. W., and Hyde, J. S.: Detection of undistorted continuous wave (CW) electron paramagnetic resonance (EPR) spectra with non-adiabatic rapid sweep (NARS) of the magnetic field, J. Magn. Reson., 211, 228–233, 2011.</mixed-citation></ref>
      <ref id="bib1.bibx15"><label>Kittell et al.(2012)Kittell, Hustedt, and Hyde</label><mixed-citation> Kittell, A. W., Hustedt, E. J., and Hyde, J. S.: Inter-spin distance determination using L-band (1–2GHz) non-adiabatic rapid sweep electron paramagnetic resonance (NARS EPR), J. Magn. Reson., 221, 51–56, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx16"><label>Knörzer et al.(2012)Knörzer, Silakov, Foster, Armstrong, Lubitz, and Happe</label><mixed-citation> Knörzer, P., Silakov, A., Foster, C. E., Armstrong, F. A., Lubitz, W., and Happe, T.: Importance of the Protein Framework for Catalytic Activity of [FeFe]-Hydrogenases, J. Biol. Chem., 287, 1489–1499, 2012.</mixed-citation></ref>
      <ref id="bib1.bibx17"><label>Lin and Mitra(1996)</label><mixed-citation> Lin, I.-S. and Mitra, S. K.: Overlapped Block Digital Filtering, IEEE T. Circuits-II, 43, 586–596, 1996.</mixed-citation></ref>
      <ref id="bib1.bibx18"><label>Lipton et al.(2002)Lipton, Smith, Adams, and Ellis</label><mixed-citation> Lipton, A. S., Smith, M. D., Adams, R. D., and Ellis, P. D.: 67Zn Solid-State and Single-Crystal NMR Spectroscopy and X-ray Crystal Structure of Zinc Formate Dihydrate, J. Am. Chem. Soc., 124, 410–414, 2002.</mixed-citation></ref>
      <ref id="bib1.bibx19"><label>O'Dell et al.(2009)</label><mixed-citation> O'Dell, L. A., Rossini, A. J., and Schurko. R. W.: Acquisition of ultra-wideline NMR spectra from quadrupolar nuclei by frequency stepped WURST-QCPMG, Chem. Phys. Lett., 468, 330–335, 2009.</mixed-citation></ref>
      <ref id="bib1.bibx20"><label>Manning et al.(2020)Manning, Cochrane, and Lenahan</label><mixed-citation>Manning, B. R., Cochrane, C. J., and Lenahan, P. M.: An improved adaptive signal averaging technique for noise reduction and tracking enhancements in continuous wave magnetic resonance, Rev. Sci. Instrum., 91, 033106,  <ext-link xlink:href="https://doi.org/10.1063/1.5123600" ext-link-type="DOI">10.1063/1.5123600</ext-link>, 2020.</mixed-citation></ref>
      <ref id="bib1.bibx21"><label>Massiot et al.(1995)Massiot, Farnan, Gautier, Trumeau, Trokiner, and Coutures</label><mixed-citation> Massiot, D., Farnan, I., Gautier, N., Trumeau, D., Trokiner, A., and Coutures, J. P.: 71Ga and 69Ga nuclear magnetic resonance study of β-Ga2O3: resolution of four- and six-fold coordinated Ga sites in static conditions, Solid State Nucl. Mag., 4, 241–248, 1995.</mixed-citation></ref>
      <ref id="bib1.bibx22"><label>Nguyen-Thanh and Koo(2013)</label><mixed-citation>Nguyen-Thanh, N. and Koo, I.: A cluster-based selective cooperative spectrum sensing scheme in cognitive radio, EURASIP J. Wirel. Comm., 2013, 176, <ext-link xlink:href="https://doi.org/10.1186/1687-1499-2013-176" ext-link-type="DOI">10.1186/1687-1499-2013-176</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx23"><label>Oppenheim et al.(1999)Oppenheim, Schafer, and Buck</label><mixed-citation>Oppenheim, A., Schafer, R., and Buck, J.: Discrete-Time Signal Processing, Pearson education signal processing series, Pearson Education, ISBN 13 978-0131988422, 1999.  </mixed-citation></ref>
      <ref id="bib1.bibx24"><label>Pell et al.(2013)Pell, Clément, Grey, Emsley, and Pintacuda</label><mixed-citation>Pell, A. J., Clément, R. J., Grey, C. P., Emsley, L., and Pintacuda, G.: Frequency-stepped acquisition in nuclear magnetic resonance spectroscopy under magic angle spinning, J. Chem. Phys., 138, 114201, <ext-link xlink:href="https://doi.org/10.1063/1.4795001" ext-link-type="DOI">10.1063/1.4795001</ext-link>, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx25"><label>Sanders et al.(2018)Sanders, Pell, Wegner, Grey, and Pintacuda</label><mixed-citation> Sanders, K. J., Pell, A. J., Wegner, S., Grey, C. P., and Pintacuda, G.: Broadband MAS NMR spectroscopy in the low-power limit, Chem. Phys. Lett., 697, 29–37, 2018.</mixed-citation></ref>
      <ref id="bib1.bibx26"><label>Schroeder(2000)</label><mixed-citation> Schroeder, D.: Astronomical Optics, Electronics &amp; Electrical, Elsevier Science, ISBN 13 978-0126298109, 2000.</mixed-citation></ref>
      <ref id="bib1.bibx27"><label>Schurko(2013)</label><mixed-citation> Schurko, R. W.: Ultra-Wideline Solid-State NMR Spectroscopy, Accounts Chem. Res., 46, 1985–1995, 2013.</mixed-citation></ref>
      <ref id="bib1.bibx28"><label>Sidabras(2026)</label><mixed-citation>Sidabras, J. W.: jsidabras/SOFFABruker: Magnetic Resonance Paper Data (PaperRelease), Zenodo [code] and [data set], <ext-link xlink:href="https://doi.org/10.5281/zenodo.20766183" ext-link-type="DOI">10.5281/zenodo.20766183</ext-link>, 2026.</mixed-citation></ref>
      <ref id="bib1.bibx29"><label>Srivastava et al.(2016)Srivastava, Anderson, and Freed</label><mixed-citation> Srivastava, M., Anderson, C. L., and Freed, J. H.: A New Wavelet Denoising Method for Selecting Decomposition Levels and Noise Thresholds, IEEE Access, 4, 3862–3877, 2016.</mixed-citation></ref>
      <ref id="bib1.bibx30"><label>Strangeway et al.(2017)Strangeway, Hyde, Camenisch, Sidabras, Mett, Anderson, Ratke, and Subczynski</label><mixed-citation> Strangeway, R. A., Hyde, J. S., Camenisch, T. G., Sidabras, J. W., Mett, R. R., Anderson, J. R., Ratke, J. J., and Subczynski, W. K.: Broadband W-band Rapid Frequency Sweep Considerations for Fourier Transform EPR, Cell Biochem. Biophys., 75, 259–273, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx31"><label>Tseitlin et al.(2011a)Tseitlin, Eaton, and Eaton</label><mixed-citation>Tseitlin, M., Eaton, S. S., and Eaton, G. R.: Reconstruction of the first-derivative EPR spectrum from multiple harmonics of the field-modulated continuous wave signal, J. Magn. Reson., 209, 277–281, <ext-link xlink:href="https://doi.org/10.1016/j.jmr.2011.01.027" ext-link-type="DOI">10.1016/j.jmr.2011.01.027</ext-link>, 2011a.</mixed-citation></ref>
      <ref id="bib1.bibx32"><label>Tseitlin et al.(2011b)Tseitlin, Rinard, Quine, Eaton, and Eaton</label><mixed-citation> Tseitlin, M., Rinard, G. A., Quine, R. W., Eaton, S. S., and Eaton, G. R.: Rapid frequency scan EPR, J. Magn. Reson., 211, 156–161, 2011b.</mixed-citation></ref>
      <ref id="bib1.bibx33"><label>Tseytlin(2017)</label><mixed-citation> Tseytlin, M.: Full cycle rapid scan EPR deconvolution algorithm, J. Magn. Reson., 281, 272–278, 2017.</mixed-citation></ref>
      <ref id="bib1.bibx34"><label>Vetterli(1987)</label><mixed-citation> Vetterli, M.: A theory of multirate filter banks, IEEE T. Acoust. Speech, 35, 356–372, 1987.</mixed-citation></ref>
      <ref id="bib1.bibx35"><label>Weger(1960)</label><mixed-citation>Weger, M.: Passage Effects in Paramagnetic Resonance Experiments, Bell Syst. Tech. J., 39, 1013–1112, <ext-link xlink:href="https://doi.org/10.1002/j.1538-7305.1960.tb03951.x" ext-link-type="DOI">10.1002/j.1538-7305.1960.tb03951.x</ext-link>, 1960.</mixed-citation></ref>
      <ref id="bib1.bibx36"><label>Welch(1967)</label><mixed-citation>Welch, P.: The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms, IEEE T. Acoust. Speech, 15, 70–73, <ext-link xlink:href="https://doi.org/10.1109/TAU.1967.1161901" ext-link-type="DOI">10.1109/TAU.1967.1161901</ext-link>, 1967.</mixed-citation></ref>
      <ref id="bib1.bibx37"><label>Wilmshurst(1990)</label><mixed-citation> Wilmshurst, T. H.: Signal recovery from noise in electronic instrumentation, IOP Publishing ltd., London, ISBN 13 978-0852747834, 1990.</mixed-citation></ref>
      <ref id="bib1.bibx38"><label>Yu et al.(2015a)Yu, Liu, Elajaili, Rinard, Eaton, and Eaton</label><mixed-citation> Yu, Z., Liu, T., Elajaili, H., Rinard, G. A., Eaton, S. S., and Eaton, G. R.: Field-stepped direct detection electron paramagnetic resonance, J. Magn. Reson., 258, 58–64, 2015a.</mixed-citation></ref>
      <ref id="bib1.bibx39"><label>Yu et al.(2015b)Yu, Tseytlin, Eaton, and Eaton</label><mixed-citation>Yu, Z., Tseytlin, M., Eaton, S. S., and Eaton, G. R.: Multiharmonic electron paramagnetic resonance for extended samples with both narrow and broad lines, J. Magn. Reson., 254, 86–92, <ext-link xlink:href="https://doi.org/10.1016/j.jmr.2015.03.006" ext-link-type="DOI">10.1016/j.jmr.2015.03.006</ext-link>, 2015b.</mixed-citation></ref>

  </ref-list></back>
    <!--<article-title-html>Segmented-overlap Fourier filtering and averaging (SOFFA) approach to improve concentration sensitivity of magnetic resonance spectra</article-title-html>
<abstract-html/>
<ref-html id="bib1.bib1"><label>Ash and Grandinetti(2006)</label><mixed-citation>
       Ash, J. T. and Grandinetti, P. J.: Solid-state NMR characterization of 69Ga and 71Ga in crystalline solids, Magn. Reson. Chem., 44, 823–831, 2006.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib2"><label>Brinton and Hirsh(2010)</label><mixed-citation>
       Brinton, C. G. and Hirsh, D. J.: Note: Sensitivity enhancement in continuous-wave electron paramagnetic resonance: Adaptive signal averaging versus a moving average, Rev. Sci. Instrum., 81, 026102, <a href="https://doi.org/10.1063/1.3293381" target="_blank">https://doi.org/10.1063/1.3293381</a>, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib3"><label>Cochrane and Lenahan(2008)</label><mixed-citation>
       Cochrane, C. and Lenahan, P.: Real time exponentially weighted recursive least squares adaptive signal averaging for enhancing the sensitivity of continuous wave magnetic resonance, J. Magn. Reson., 195, 17–22, 2008.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib4"><label>Eaton et al.(2014)Eaton, Quine, Tseitlin, Mitchell, Rinard, and Eaton</label><mixed-citation>
       Eaton, S. S., Quine, R. W., Tseitlin, M., Mitchell, D. G., Rinard, G. A., and Eaton, G. R.: Rapid-Scan Electron Paramagnetic Resonance, chap. 2,  3–67, Wiley-Blackwell, <a href="https://doi.org/10.1002/9783527672431" target="_blank">https://doi.org/10.1002/9783527672431</a>, 2014.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib5"><label>Harris(1978)</label><mixed-citation>
       Harris, F. J.: On the use of windows for harmonic analysis with the discrete Fourier transform, P. IEEE, 66, 51–83, <a href="https://doi.org/10.1109/PROC.1978.10837" target="_blank">https://doi.org/10.1109/PROC.1978.10837</a>, 1978.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib6"><label>Hyde et al.(1990)Hyde, Pasenkiewicz-Gierula, Jesmanowicz, and Antholine</label><mixed-citation>
       Hyde, J. S., Pasenkiewicz-Gierula, M., Jesmanowicz, A., and Antholine, W. E.: Pseudo field modulation in EPR spectroscopy, Appl. Magn. Reson., 1, <a href="https://doi.org/10.1007/bf03166028" target="_blank">https://doi.org/10.1007/bf03166028</a>, 1990.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib7"><label>Hyde et al.(2010)Hyde, Strangeway, Camenisch, Ratke, and Froncisz</label><mixed-citation>
       Hyde, J. S., Strangeway, R. A., Camenisch, T. G., Ratke, J. J., and Froncisz, W.: W-band frequency-swept EPR, J. Magn. Reson., 205, 93–101, 2010.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib8"><label>Hyde et al.(2013)Hyde, Bennett, Kittell, Kowalski, and Sidabras</label><mixed-citation>
       Hyde, J. S., Bennett, B., Kittell, A. W., Kowalski, J. M., and Sidabras, J. W.: Moving difference (MDIFF) non-adiabatic rapid sweep (NARS) EPR of copper(II), J. Magn. Reson., 236, 15–25, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib9"><label>Hyde et al.(2022)Hyde, Strangeway, and Sidabras</label><mixed-citation>
       Hyde, J. S., Strangeway, R. A., and Sidabras, J. W.: Dispersion EPR: Considerations for low-frequency experiments, Appl. Magn. Reson., 53, 193–206, 2022.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib10"><label>Ifeachor and Jervis(2002)</label><mixed-citation>
       Ifeachor, E. and Jervis, B.: Digital Signal Processing: A Practical Approach, Electronic systems engineering series, Prentice Hall, ISBN 13 978-0201544138, 2002.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib11"><label>Ivanov et al.(2016)Ivanov, Nadolinny, Bagryanskaya, Grishin, Fedin, and Veber</label><mixed-citation>
       Ivanov, M. Y., Nadolinny, V. A., Bagryanskaya, E. G., Grishin, Y. A., Fedin, M. V., and Veber, S. L.: Bismuth germanate as a perspective material for dielectric resonators in EPR spectroscopy, J. Magn. Reson., 271, 83–89, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib12"><label>Karami and Saarnisaari(2018)</label><mixed-citation>
       Karami, E. and Saarnisaari, H.: Windowed overlapped frequency domain block filtering approach for direct sequence signal acquisition, Digit. Commun. Netw., 4, 209–216, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib13"><label>Kittell and Hyde(2015)</label><mixed-citation>
       Kittell, A. W. and Hyde, J. S.: Spin-label CW microwave power saturation and rapid passage with triangular non-adiabatic rapid sweep (NARS) and adiabatic rapid passage (ARP) EPR spectroscopy, J. Magn. Reson., 255, 68–76, 2015.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib14"><label>Kittell et al.(2011)Kittell, Camenisch, Ratke, Sidabras, and Hyde</label><mixed-citation>
       Kittell, A. W., Camenisch, T. G., Ratke, J. J., Sidabras, J. W., and Hyde, J. S.: Detection of undistorted continuous wave (CW) electron paramagnetic resonance (EPR) spectra with non-adiabatic rapid sweep (NARS) of the magnetic field, J. Magn. Reson., 211, 228–233, 2011.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib15"><label>Kittell et al.(2012)Kittell, Hustedt, and Hyde</label><mixed-citation>
       Kittell, A. W., Hustedt, E. J., and Hyde, J. S.: Inter-spin distance determination using L-band (1–2GHz) non-adiabatic rapid sweep electron paramagnetic resonance (NARS EPR), J. Magn. Reson., 221, 51–56, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib16"><label>Knörzer et al.(2012)Knörzer, Silakov, Foster, Armstrong, Lubitz, and Happe</label><mixed-citation>
       Knörzer, P., Silakov, A., Foster, C. E., Armstrong, F. A., Lubitz, W., and Happe, T.: Importance of the Protein Framework for Catalytic Activity of [FeFe]-Hydrogenases, J. Biol. Chem., 287, 1489–1499, 2012.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib17"><label>Lin and Mitra(1996)</label><mixed-citation>
       Lin, I.-S. and Mitra, S. K.: Overlapped Block Digital Filtering, IEEE T. Circuits-II, 43, 586–596, 1996.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib18"><label>Lipton et al.(2002)Lipton, Smith, Adams, and Ellis</label><mixed-citation>
       Lipton, A. S., Smith, M. D., Adams, R. D., and Ellis, P. D.: 67Zn Solid-State and Single-Crystal NMR Spectroscopy and X-ray Crystal Structure of Zinc Formate Dihydrate, J. Am. Chem. Soc., 124, 410–414, 2002.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib19"><label>O'Dell et al.(2009)</label><mixed-citation>
       O'Dell, L. A., Rossini, A. J., and Schurko. R. W.: Acquisition of ultra-wideline NMR spectra from quadrupolar nuclei by frequency stepped WURST-QCPMG, Chem. Phys. Lett., 468, 330–335, 2009.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib20"><label>Manning et al.(2020)Manning, Cochrane, and Lenahan</label><mixed-citation>
       Manning, B. R., Cochrane, C. J., and Lenahan, P. M.: An improved adaptive signal averaging technique for noise reduction and tracking enhancements in continuous wave magnetic resonance, Rev. Sci. Instrum., 91, 033106,  <a href="https://doi.org/10.1063/1.5123600" target="_blank">https://doi.org/10.1063/1.5123600</a>, 2020.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib21"><label>Massiot et al.(1995)Massiot, Farnan, Gautier, Trumeau, Trokiner, and Coutures</label><mixed-citation>
       Massiot, D., Farnan, I., Gautier, N., Trumeau, D., Trokiner, A., and Coutures, J. P.: 71Ga and 69Ga nuclear magnetic resonance study of β-Ga2O3: resolution of four- and six-fold coordinated Ga sites in static conditions, Solid State Nucl. Mag., 4, 241–248, 1995.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib22"><label>Nguyen-Thanh and Koo(2013)</label><mixed-citation>
       Nguyen-Thanh, N. and Koo, I.: A cluster-based selective cooperative spectrum sensing scheme in cognitive radio, EURASIP J. Wirel. Comm., 2013, 176,
<a href="https://doi.org/10.1186/1687-1499-2013-176" target="_blank">https://doi.org/10.1186/1687-1499-2013-176</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib23"><label>Oppenheim et al.(1999)Oppenheim, Schafer, and Buck</label><mixed-citation>
       Oppenheim, A., Schafer, R., and Buck, J.: Discrete-Time Signal Processing, Pearson education signal processing series, Pearson Education, ISBN 13 978-0131988422, 1999.


    </mixed-citation></ref-html>
<ref-html id="bib1.bib24"><label>Pell et al.(2013)Pell, Clément, Grey, Emsley, and Pintacuda</label><mixed-citation>
       Pell, A. J., Clément, R. J., Grey, C. P., Emsley, L., and Pintacuda, G.: Frequency-stepped acquisition in nuclear magnetic resonance spectroscopy under magic angle spinning, J. Chem. Phys., 138, 114201, <a href="https://doi.org/10.1063/1.4795001" target="_blank">https://doi.org/10.1063/1.4795001</a>, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib25"><label>Sanders et al.(2018)Sanders, Pell, Wegner, Grey, and Pintacuda</label><mixed-citation>
       Sanders, K. J., Pell, A. J., Wegner, S., Grey, C. P., and Pintacuda, G.: Broadband MAS NMR spectroscopy in the low-power limit, Chem. Phys. Lett., 697, 29–37, 2018.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib26"><label>Schroeder(2000)</label><mixed-citation>
       Schroeder, D.: Astronomical Optics, Electronics &amp; Electrical, Elsevier Science, ISBN 13 978-0126298109, 2000.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib27"><label>Schurko(2013)</label><mixed-citation>
       Schurko, R. W.: Ultra-Wideline Solid-State NMR Spectroscopy, Accounts Chem. Res., 46, 1985–1995, 2013.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib28"><label>Sidabras(2026)</label><mixed-citation>
      
Sidabras, J. W.: jsidabras/SOFFABruker: Magnetic Resonance Paper Data (PaperRelease), Zenodo [code] and [data set], <a href="https://doi.org/10.5281/zenodo.20766183" target="_blank">https://doi.org/10.5281/zenodo.20766183</a>, 2026.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib29"><label>Srivastava et al.(2016)Srivastava, Anderson, and Freed</label><mixed-citation>
       Srivastava, M., Anderson, C. L., and Freed, J. H.: A New Wavelet Denoising Method for Selecting Decomposition Levels and Noise Thresholds, IEEE Access, 4, 3862–3877, 2016.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib30"><label>Strangeway et al.(2017)Strangeway, Hyde, Camenisch, Sidabras, Mett, Anderson, Ratke, and Subczynski</label><mixed-citation>
       Strangeway, R. A., Hyde, J. S., Camenisch, T. G., Sidabras, J. W., Mett, R. R., Anderson, J. R., Ratke, J. J., and Subczynski, W. K.: Broadband W-band Rapid Frequency Sweep Considerations for Fourier Transform EPR, Cell Biochem. Biophys., 75, 259–273, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib31"><label>Tseitlin et al.(2011a)Tseitlin, Eaton, and Eaton</label><mixed-citation>
       Tseitlin, M., Eaton, S. S., and Eaton, G. R.: Reconstruction of the first-derivative EPR spectrum from multiple harmonics of the field-modulated continuous wave signal, J. Magn. Reson., 209, 277–281, <a href="https://doi.org/10.1016/j.jmr.2011.01.027" target="_blank">https://doi.org/10.1016/j.jmr.2011.01.027</a>, 2011a.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib32"><label>Tseitlin et al.(2011b)Tseitlin, Rinard, Quine, Eaton, and Eaton</label><mixed-citation>
       Tseitlin, M., Rinard, G. A., Quine, R. W., Eaton, S. S., and Eaton, G. R.: Rapid frequency scan EPR, J. Magn. Reson., 211, 156–161, 2011b.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib33"><label>Tseytlin(2017)</label><mixed-citation>
       Tseytlin, M.: Full cycle rapid scan EPR deconvolution algorithm, J. Magn. Reson., 281, 272–278, 2017.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib34"><label>Vetterli(1987)</label><mixed-citation>
       Vetterli, M.: A theory of multirate filter banks, IEEE T. Acoust. Speech, 35, 356–372, 1987.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib35"><label>Weger(1960)</label><mixed-citation>
       Weger, M.: Passage Effects in Paramagnetic Resonance Experiments, Bell Syst. Tech. J., 39, 1013–1112, <a href="https://doi.org/10.1002/j.1538-7305.1960.tb03951.x" target="_blank">https://doi.org/10.1002/j.1538-7305.1960.tb03951.x</a>, 1960.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib36"><label>Welch(1967)</label><mixed-citation>
       Welch, P.: The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms, IEEE T. Acoust. Speech, 15, 70–73, <a href="https://doi.org/10.1109/TAU.1967.1161901" target="_blank">https://doi.org/10.1109/TAU.1967.1161901</a>, 1967.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib37"><label>Wilmshurst(1990)</label><mixed-citation>
       Wilmshurst, T. H.: Signal recovery from noise in electronic instrumentation, IOP Publishing ltd., London, ISBN 13 978-0852747834, 1990.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib38"><label>Yu et al.(2015a)Yu, Liu, Elajaili, Rinard, Eaton, and Eaton</label><mixed-citation>
       Yu, Z., Liu, T., Elajaili, H., Rinard, G. A., Eaton, S. S., and Eaton, G. R.: Field-stepped direct detection electron paramagnetic resonance, J. Magn. Reson., 258, 58–64, 2015a.

    </mixed-citation></ref-html>
<ref-html id="bib1.bib39"><label>Yu et al.(2015b)Yu, Tseytlin, Eaton, and Eaton</label><mixed-citation>
       Yu, Z., Tseytlin, M., Eaton, S. S., and Eaton, G. R.: Multiharmonic electron paramagnetic resonance for extended samples with both narrow and broad lines, J. Magn. Reson., 254, 86–92, <a href="https://doi.org/10.1016/j.jmr.2015.03.006" target="_blank">https://doi.org/10.1016/j.jmr.2015.03.006</a>, 2015b.

    </mixed-citation></ref-html>--></article>